Page 4
Except as may be expressly stated anywhere in this manual, nothing herein shall be construed as any kind of guarantee or warranty by ABB for losses, damage to persons or property, fitness for a specific purpose or the like.
Page 5
Controller description OmniCore C90XT Type A ..................Technical data for OmniCore C90XT Type A controller ..........Safety functions and safety related data for OmniCore C90XT Type A ......The unit is sensitive to ESD ................. Handling of FlexPendant ..................Network security ....................
Page 9
Product manual scope The manual covers all variants and designs of the OmniCore C90XT Type A. Some variants and designs may have been removed from the business offer and are no longer available for purchase.
Page 10
Overview of this manual Continued References All documents can be found via myABB Business Portal, www.abb.com/myABB. Document name Document ID Product specification - OmniCore C line 3HAC065034-001 Circuit diagram - OmniCore C90XT Type A 3HAC086305-010 User manual - FlexPendant 3HAC093167-001...
Page 11
Product documentation Categories for user documentation from ABB Robotics The user documentation from ABB Robotics is divided into a number of categories. This listing is based on the type of information in the documents, regardless of whether the products are standard or optional.
Page 15
Limitation of liability Any information given in this manual regarding safety must not be construed as a warranty by ABB that the industrial robot will not cause injury or damage even if all safety instructions are complied with. The information does not cover how to design, install and operate a robot system, nor does it cover all peripheral equipment that can influence the safety of the robot system.
Page 16
Extended Safety Functions. Performance level data The performance level data for the respective controller variant is presented in section Safety functions and safety related data for OmniCore C90XT Type A on page Product manual - OmniCore C90XT Type A 3HAC089065-001 Revision: A-ongoing...
Page 35
The manipulator can move unexpectedly at any time. DANGER Troubleshooting on the controller while powered on must be performed by personnel trained by ABB or by ABB field engineers. A risk assessment must be done to address both robot and robot system specific hazards.
Page 37
2.1 OmniCore C90XT Type A About OmniCore C90XT Type A The OmniCore C90XT Type A is one of OmniCore C line compact controllers. The OmniCore C90XT Type A controller offers a compact solution suitable for most applications with room for some additional equipment inside.
Page 38
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller 2.2 Technical data for OmniCore C90XT Type A controller Overview of the controller OmniCore C90XT Type A is intended to be used in industrial environment. xx2400001212 X2,X3 Reserved interface...
Page 39
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller Continued X104 X103 K5.1 K5.2,3 PE-BUS xx2400001319 Reference OmniCore C90XT to circuit Type A diagram Basic box Baseline Extension box Option Drive unit Baseline Power unit Baseline SMB connector...
Page 40
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller Continued Reference OmniCore C90XT to circuit Type A diagram Heat exchanger Baseline Axis computer Main computer Baseline DeviceNet A2.K2 Option Power supply Power supply DSQC 609 power supply...
Page 41
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller Continued Extension box Parameter Value Width 500 mm Depth 355 mm Height 295 mm Weight Controller Weight OmniCore C90XT Type A 46 kg (not including the extension box)
Page 42
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller Continued Note The humidity conditions shall apply with the environmental conditions EN 60721-3-3, climatic class 3K3. For temperatures 0-30°C, the relative humidity must not exceed 85%. For temperatures exceeding 30°C, the absolute humidity...
Page 43
Continued Line fusing There is no integrated fuse inside the OmniCore C90XT Type A controller. Add an external fuse (time-delay) or circuit breaker (class K) according to full load current, as marked on the controller nameplate. The following table shows the recommended rating for an external fuse or circuit breaker.
Page 44
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller Continued Drive system The drive system provides motion power and absorbs excess braking energy when the robot is running. The drive system label, which is placed on the top of the controller, contains...
Page 45
2 Controller description 2.2 Technical data for OmniCore C90XT Type A controller Continued Manipulator Controller Drive system type CRB 15000-10/1.52 OmniCore C30 CRB 15000-10/1.52 OmniCore C30 Type A CRB 15000-12/1.27 OmniCore C30 CRB 15000-12/1.27 OmniCore C30 Type A Note Controllers with different drive systems are not interchangeable.
Page 46
2 Controller description 2.3 Safety functions and safety related data for OmniCore C90XT Type A 2.3 Safety functions and safety related data for OmniCore C90XT Type A Note During the mission time, the three-position enabling device on the FlexPendant can handle a maximum demand rate of 10 x 7d x 52w x 20y operations; the emergency stop on the FlexPendant can handle a maximum demand rate of 4 x 7d x 52w x 20y operations.
Page 47
2 Controller description 2.3 Safety functions and safety related data for OmniCore C90XT Type A Continued Extended Safety Functions For extended safety functions, see Application manual - Functional safety and SafeMove, 3HAC066559-001 and the corresponding application manual for protocols PROFINET/PROFIsafe and EtherNet/IP, CIP safety.
Page 50
FCC statement Changes or modification to the FlexPendant not expressly approved by ABB will void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the...
Page 51
ABB Ltd and its entities are not liable for damage and/or loss related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information.
Page 52
The third party license terms apply only to the respective software to which the license pertains, and the third party license terms do not apply to ABB products. With regard to programs provided under the GNU general public license and the GNU lesser general public license licensor will provide licensee on demand, a machine-readable copy of the corresponding source code.
Page 53
Note ABB Connected Services is the new name for the functionality previously known as ABB Ability. During a period of time, both names will appear in and on our products. The OmniCore™ controller hardware is delivered with a standard mobile connection (Cellular data connection), or WIFI modem and/or Ethernet connection.
Page 54
Changes or modifications not expressly approved by ABB could void the user’s authority to operate the equipment under FCC rules. When the optional connectivity module is installed, the operating conditions must be such that there is a minimum separation distance of 20 cm between the dedicated antenna and nearby persons or other antennas.
Page 55
Continued Data ABB will not acquire any right, title and interest in the data other than the rights granted by Customer to ABB, but ABB will have the right to collect, store, aggregate, analyze or otherwise use the data for (i) providing and maintaining the hardware, services and/or the ABB software to Customer;...
Page 61
Check for any visible transport damage. Note Stop unpacking and contact ABB if transport damage is found. Clean the unit with a lint-free cloth, if necessary. Make sure that the lifting accessory used (if applicable) is suitable to handle the weight of the controller.
Page 65
3.4.2 Securing and stacking the controller cabinet Securing the controller The controller can be secured to the ground. The figure below shows the bolt pattern for the OmniCore C90XT Type A controller. The diameter of the four bolt holes are 14 mm. 11(4X)
Page 75
CAUTION Always inspect the connector for dirt or damage before connecting it to the controller. Clean or replace any damaged parts. Connectors The following details the connection interface on the OmniCore C90XT Type A controller. xx2400001320 Description Manipulator signal connector...
Page 76
3 Installation and commissioning 3.5.1 Connectors on the OmniCore C90XT Type A controller Continued Description TPU cover FlexPendant connection (TPU connector) ETH outlet connector Motors on lamp Power inlet switch Product manual - OmniCore C90XT Type A 3HAC089065-001 Revision: A-ongoing...
Page 85
Female insert, quick lock Angle hood M20 Cable gland M20 Sealing screw Specifications The following describes the cable requirements for the incoming mains connection to the OmniCore C90XT Type A controller. Component Description Cable type Flexible oil resistant rubber Cable area 3C x 2.5 mm...
Page 90
Line fusing There is no integrated fuse in side OmniCore C90XT Type A controller. An external fuse or circuit breaker must be added by the integrator, according to the full load current rating. The full load current for the robot is marked on the controller name...
Page 95
Note The management port shall never be used for more than one client at a time. ABB Robotics assumes no responsibility for any errors/hazards that may appear when more than one client is used.
Page 104
If separate power supplies are used for each channel (Ch1, Ch2) they must have common ground. For more connections other than those illustrated above, carefully assess the risk before use and contact your local ABB for support. Connector X15 Description...
Page 108
3 Installation and commissioning 3.5.8 Descriptions for connectors Continued Antenna connector The Connected Services Gateway unit has either an ABB Connect port or an antenna connector on the front. See installation procedures in section On-site installation on page xx1900002450 The 4G Connected Services Gateway unit has an antenna connector on the front.
Page 109
The connectors contain 16 digital input signals, 16 digital output signals, 24 V and 0 V for the outputs. For connection details, see Circuit diagram - OmniCore C90XT Type A, 3HAC086305-010 and Application manual - Scalable I/O, 3HAC070208-001. Conveyor tracking module (option) For detail information on customer connections to conveyor tracking module, see Application manual - Conveyor tracking, 3HAC066561-001.
Page 110
Note The 24 V terminal block power supply is isolated from the internal logical circuit of the controller. For connection details, see Circuit diagram - OmniCore C90XT Type A, 3HAC086305-010. Customer cable layout It is recommended to use multicore cable for the customer connection.
Page 112
7 After the configuration is done, the safety configuration must be transferred to the controller and then a restart of the controller is required. See also the circuit diagram, Circuit diagram - OmniCore C90XT Type A. Apply the configuration to the controller...
Page 119
I/O base device. Scalable I/O devices The I/O device DSQC1030 Digital Base belongs to the ABB Scalable I/O system, which is a modular, compact, and scalable I/O system that consists of a base device (minimum configuration), and add-on devices.
Page 120
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 128
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 131
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 134
ABB products such as Track Motion, Positioners, Motor Units, Gear Units are equipped with integrated brake snubbers. When integrating a motor not delivered by ABB, it is of great importance that the motor has a snubber fitted across the brake terminals, at the motor. Failure to do so will void warranty and may result in drive unit failure.
Page 135
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 139
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 143
Required parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number Note...
Page 146
It is recommended to use icotek KT grommet. Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 152
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 154
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 157
The motor connection box location is decided by the customer. Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 160
Application manual - MultiMove. Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 166
Install the equipment to the extension box according to your requirements. WARNING ABB only offers the extension box as an encapsulation for customer installing extern- al devices. It is the system builder's responsibly to en- sure the complacence with electrical safety, for example the Low Voltage Directive.
Page 167
Required parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number Note...
Page 170
Only LVD equipments can be installed on the door of the controller. WARNING ABB only offers the extension box as an encapsulation for customer installing external devices. It is the system builder's responsibly to ensure the complacence with electrical safety, for example the Low Voltage Directive.
Page 174
4 Maintenance 4.2.1 Inspection of controller 4.2 Inspection activities 4.2.1 Inspection of controller Inspecting the OmniCore C90XT Type A controller Action Note/illustration DANGER Before doing any work inside the cabinet, disconnect the mains power. For more information, see Electrical safety on...
Page 195
Allow the surfaces to cool down before maintenance or repair. Note When replacing a part on the OmniCore C90XT Type A, report to your local ABB the serial number, the article number, and the revision of both the replaced unit and the replacement unit.
Page 197
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 208
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 212
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 216
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 226
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 236
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 241
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 245
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 256
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 260
OFF position. Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 268
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 274
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 278
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 282
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 287
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 291
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 295
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 301
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 306
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 329
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 336
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 342
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 349
Power cable Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 354
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 357
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 358
The motor connection box location is decided by the customer. Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 360
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 365
Required spare parts Note The spare part numbers that are listed in the table can be out of date. See the latest spare parts of the OmniCore C90XT Type A via myABB Business Portal, www.abb.com/myABB. Spare part Article number...
Page 370
6.2 Environmental information 6.2 Environmental information Introduction ABB robots contain components in different materials. During decommissioning, all materials shall be dismantled, recycled, or reused responsibly, according to the relevant laws and industrial standards. Robots or parts that can be reused or upcycled helps to reduce the usage of natural resources.
Page 371
China RoHS symbol The following symbol shows the information to hazardous substances and the environmental protection use period of OmniCore C90XT Type A according to "Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products (SJ/T 11364-2014) ".
Page 376
Check the FlexPendant for errors and warnings. DANGER Troubleshooting on the controller while powered on must be performed by personnel trained by ABB or by ABB field engineers. Recommended working procedure If no LEDs are lit on the controller during start-up, use this procedure to troubleshoot what might cause the problem.
Page 377
Required test equipment Equipment needed for troubleshooting: Equipment Note Multimeter Insulating gloves Circuit diagram - OmniCore C90XT Type A 3HAC086305-010 Preparations Action Make sure that the controller is switched on. Wait 30 s - 1 min to enable start-up sequence.
Page 380
Required test equipment Equipment needed for troubleshooting: Equipment Note Multimeter Insulating gloves Circuit diagram - OmniCore C90XT Type A 3HAC086305-010 Preparations Action Make sure that the controller is switched on. Wait 30 s - 1 min to enable start-up sequence.
Page 382
Required test equipment Equipment needed for troubleshooting: Equipment Note Multimeter Insulating gloves Circuit diagram - OmniCore C90XT Type A 3HAC086305-010 Preparations Action Make sure that the controller is switched on. Wait 30 s - 1 min to enable start-up sequence.
Page 383
Action DANGER Troubleshooting on the controller while powered on must be performed by personnel trained by ABB or by ABB field engineers. Recommended working procedure If the FlexPendant starts but does not display the main interface during the start-up, use this procedure to troubleshoot what might cause the problem.
Page 389
Required test equipment Equipment needed for troubleshooting: Equipment Note Multimeter Insulating gloves Circuit diagram - OmniCore C90XT Type A 3HAC086305-010 Preparations Action Make sure that the controller is switched on. Wait 30 s - 1 min to enable start-up sequence.
Page 396
7 Troubleshooting 7.3.4 Troubleshooting the additional drive unit (DSQC3065) Continued Equipment Note Circuit diagram - OmniCore C90XT Type A 3HAC086305-010 Preparations Action Check the FlexPendant for errors and warnings. Power the controller off. Wait one minute, power the controller on.
Page 406
216. Related information All documents can be found via myABB Business Portal, www.abb.com/myABB. The approval code CMIIT ID is displayed on the nameplate of the product. Product manual - OmniCore C90XT Type A 3HAC089065-001 Revision: A-ongoing...
Page 410
CAUTION The ABB 4G gateway has been preconfigured in factory. Resetting the gateway will make it unusable and warranty is lost. Contact ABB if reset is required. Troubleshooting procedures The troubleshooting table is supposed to be used as a detailed instruction together with the troubleshooting flowchart.
Page 414
3 The Log view displays all current logs: xx2300000911 4 The Log download and Support Packet pages allow saving logs for ABB troubleshooting. These logs can be saved as a file and be sent to ABB L3/L4 Support for analysis. •...
Page 432
In all repair and maintenance instructions, weights of the components handled are sometimes specified. All components exceeding 22 kg (50 lbs) are high-lighted in this way. To avoid injury, ABB recommends the use of lifting equipment when handling components with a weight exceeding 22 kg. Example...
Page 435
9 Spare parts 9 Spare parts Spare part level ABB spare parts are categorized into two levels, L1 and L2. Always check the part level before conducting a service work on a spare part. • L1 spare parts The L1 parts can be replaced in the field. The maintenance and replacement instructions given in the related product manuals must be strictly followed.