Download Print this page

Altronix TROVE PLUS T1M1CK1 Installation Manual page 2

Altronix/mercury wired kits. 4 door kit with fused outputs, 4 door kit with ptc outputs, 2 door kit with fused outputs, 2 door kit with ptc outputs, 4 door kit with fused outputs

Advertisement

Altronix Trove Plus kits are pre-wired, pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/
charger and sub-assemblies, wire harnesses and finger duct.
120VAC
60Hz
Altronix
Input
Model
Current
Number
(A)
T1M1CK1
T1M1CK2
T1M1CK3
3.5
T1M1CK1D
T1M1CK2D
T1M1CK3D
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the
wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners.
Place the enclosure's upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch
bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access
Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Mercury modules to backplane(s), refer to page 3.
5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow4NB
and corresponding Installation Guides for PDS8(CB), VR6, and ACM4(CB)
for further installation instructions.
Hardware:
Snap On Spacer
|
- 2 -
Configuration Chart:
Nominal DC
Output Voltage
[DC]
Power
Power
Supply
Supply
Board
Board
Input
Battery
Output
Fuse
Fuse
Range
Rating
Rating
(VDC)
20.17-
26.4
20.17-
26.4
20.17-
26.4
5A/
10A/
250V
32V
20.17-
26.4
20.17-
26.4
20.17-
26.4
Installation Instructions:
5/16" Pan Head Screw |
Overview:
[Aux]
Maximum Supply
Current for Main
Outputs on Power
Supply board and
Output
ACM4(CB) Access
Range
Power Controller's
(VDC)
outputs
20.28-
26.4
20.28-
26.4
20.28-
26.4
24VDC @ 3.8A
20.28-
26.4
20.28-
26.4
20.28-
26.4
Lock Nut
Fail-
Safe/
Fail-
Secure
Outputs
10A/
3A/
32V
32V
4
9A
2.5A
Enclosure
Edge of
Enclosure
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
T1M1CK Series Installation Guide
10A/
3A/
250V
32V
9A
2.5A
Fig. 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the TROVE PLUS T1M1CK1 and is the answer not in the manual?

This manual is also suitable for:

Trove plus t1m1ck1dTrove plus t1m1ck2Trove plus t1m1ck2dTrove plus t1m1ck3