Model Y483C41 Eight-Channel ICP®/Voltage/Charge Sensor Signal Conditioner Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
Manual Number: 46953 Manual Revision: B ECO Number: 47035 PCB PIEZOTRONICS, INC. 3425 WALDEN AVENUE DEPEW, NY 14043-2495 PHONE 716-684-0001 FAX 716-684-0987 ® ICP is a registered trademark of PCB Group, Inc.
Page 7
Table of Contents Table of Contents Table of Figures 1-0. INTRODUCTION AND SPECIFICATIONS 1-1. Introduction: Safety Considerations 1-2. System Description ® 1-2.1 Input/Output Mode 1-3. Block Diagram 1-4. Installation 1-4.1 Grounding Techniques 1-5. Operation: Standard AC Line 1-6. Maintenance and Repair 2-0.
Page 8
MODEL 483C41 GENERAL OPERATION MANUAL 9) Auto Range 10) Switched Output 11) Clamp 12) Bias Measurement 13) Channel Output Measurement 14) Calibration 15) LED Test 16) Firmware Version 17) Unit ID 18) Reset to Factory Default Settings 19) Display Content Options 20) Save Current Settings 21) Reserved 4-0.
Page 9
MODEL 483C41 GENERAL OPERATION MANUAL Table of Figures Figure 1 Typical Block Diagram ................2 ® Figure 2 ICP Sensor Excitation ................3 Figure 3 Input Fault Window Comparator with LED Indicator ......4 Figure 4 Input Amplifier Configuration ...............4 Figure 5 Selectable Gain Amplifier Configuration ..........4 Figure 6 Overload Window Comparator .............6...
Page 10
WARNING 2: This equipment is designed with user safety in mind; however, the protection provided by the equipment may be impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. Caution 1: Cables can kill your equipment. High voltage ElectroStatic Discharge (ESD) can damage electrical devices.
Page 11
MODEL 483C41 GENERAL OPERATION MANUAL 1-2. System Description The 483C41 is an eight channel signal conditioner designed to interface measurement signals to readout or recording ® devices. This model also serves to provide excitation power for ICP sensors and in-line charge converters. The following are the features of the 483C41: ...
Page 12
MODEL 483C41 GENERAL OPERATION MANUAL 1-4.1. Grounding Techniques Integrating this model into an application that links the outputs to other test equipment powered by line voltages may lead to errors or loss of signal-to-noise ratio due to ground loops. The evidence of ground loops is easily seen whenever the fundamental frequency (50 or 60 Hz) or a multiple of the fundamental frequency is present in the system when the sensors are “at rest.”...
Page 13
MODEL 483C41 GENERAL OPERATION MANUAL 2-2. Input Protection The input section has protection to limit the amplitude of the incoming signal to within +24 volts to ground. Reference spec sheet for maximum input signal. ® 2-3. Input Fault Detection ® mode, “short”...
Page 14
MODEL 483C41 GENERAL OPERATION MANUAL 2-6. Normalized Output Sensitivity The definition of normalized output sensitivity is the calculation of the individual channel’s gain, depending on the sensitivity of the sensor attached and the desired output sensitivity. This is simply a function of the desired output sensitivity (in Volts/ unit) divided by the sensor’s sensitivity.
Page 15
MODEL 483C41 GENERAL OPERATION MANUAL Figure 6 /Overload Window Comparator 2-9. Connector Configuration This model has eight BNC jack output connectors, located on the rear panel, which are used regardless of the input mode being used. The rear panel also includes eight BNC jack input connectors that are used for all input modes. 2-10.
Page 16
MODEL 483C41 GENERAL OPERATION MANUAL Current excitation = 4.0 mA Output Filter = Disabled Coupling = AC Clamp = OFF Gain Type = Gain 3-3. Main Menu Format Initially, pressing any button will cause the first two menu lines to be displayed and the cursor will blink on the ‘Gain’ option.
Page 17
MODEL 483C41 GENERAL OPERATION MANUAL If the user attempts to use a menu selection (SENS, FSOT, FSIN, GAIN) that conflicts with the GType setting the message ‘Invalid Item for Gain Entry Type’ will be displayed. Gain (GAIN on front panel): Directly sets the gain value of each channel. For ICP®/voltage input modes: .1 to 200.0. For charge mode: .01 to 2000.0.
Page 18
MODEL 483C41 GENERAL OPERATION MANUAL 2) Sensor Input Mode (INPT on front panel): The 483C41 allows the user to switch between ICP, Voltage, Charge modes. The factory default for all channels is ICP. To change the mode select the INPT option from the main menu using the left / right arrow keys until the cursor is over the INPT option, and then press the Enter button.
Page 19
MODEL 483C41 GENERAL OPERATION MANUAL EXCi EXCv FLTo ACDC ZERO ARNG The following submenu will appear. Choose the channel you wish to change by using the up and down arrow keys. Next, use the left / right arrow key to move the flashing cursor over to the Out Filter column. To change the Filter setting, use either the up ...
Page 20
MODEL 483C41 GENERAL OPERATION MANUAL EXCi EXCv FLTo ACDC ZERO ARNG The following message will show if it is activated. This Option is Not Installed 7) Input Coupling (ACDC on front panel): The input coupling option is not applicable to the 483C41 units. 483C41 is AC coupled only. EXCi EXCv FLTo...
Page 21
MODEL 483C41 GENERAL OPERATION MANUAL EXCi EXCv FLTo ACDC ZERO ARNG The following message will show if it is activated. This Option is Not Installed 10) Switched Output (SWOT on front panel): The Switched Output option is not applicable to the 483C41 units. SWOT CLMP Bias CHRD...
Page 22
MODEL 483C41 GENERAL OPERATION MANUAL SWOT CLMP Bias CHRD LEDS Using the ENTER button, the submenu appears as shown in the following diagram. Choose the channel you wish to change by using the up and down arrow keys. The bias reading for the channel will be displayed automatically when the channel is selected.
Page 23
MODEL 483C41 GENERAL OPERATION MANUAL Chan Cal Mode 100Hz 15) LED Test (LEDS on front panel): The testing of the front panel LEDs allows checking whether or not they are functioning properly. To test them, place the cursor over the word “LEDS” on the display and press enter. CHRD LEDS Ver?
Page 24
MODEL 483C41 GENERAL OPERATION MANUAL The following submenu will appear. Use the up or down arrow key to change the Unit Id setting to a new value. Once you have the desired setting selected hit ENTER to apply it. Current Unit # NOTE: Changing the Unit ID is only necessary if you have the Ethernet or RS-232 communication option installed and you are communicating with more than one unit.
Page 25
MODEL 483C41 GENERAL OPERATION MANUAL 20) Save Current Settings (Savs on front panel): When activated the save settings command forces the units current settings to become the default power up settings. These new settings will be implemented the next time the unit is powered on. Ver? Unit Reset...
Page 26
MODEL 483C41 GENERAL OPERATION MANUAL Selecting an item from the list, shown below, highlights the item in the list and enables more icons. Select Assign IP and the following screen will appear. Select whether you want to assign a static IP address that is appropriate for your network or have it assigned from a network server.
Page 27
MODEL 483C41 GENERAL OPERATION MANUAL Important Note: The communication protocol requires a unit id as part of the command header. The unit id is not the IP address. To send commands to the unit Via Ethernet you must address the TCP-IP packets with the proper IP address and ensure the packet payload contains the correct Unit Id in the command header.
Page 29
MODEL 483C41 GENERAL OPERATION MANUAL 4-3. Communication Guidelines 1) Data transfer from the host terminal to the unit must contain an ending delimiter of <CR><LF>. Example: <CR><LF> -Carriage Return and Line feed. (In ASCII, <CR> is 13; <LF> is 10.) 2) The number of characters for any command string, from the first character to the <CR>, may not exceed 255.
Page 30
MODEL 483C41 GENERAL OPERATION MANUAL 4-5. Command Summary The table below is a summary of the command set. Some commands may not be valid in all units. The commands are sent and received from/to the host computer in ASCII text format. Command Type Scope...
Page 31
MODEL 483C41 GENERAL OPERATION MANUAL Command examples: 1:0:GAIN=100.2\r\n unit 1,all channels gain set to 100.2 1:1:GAIN=100.2;2:GAIN=120.3\r\n unit 1, channel 1 gain = 100.2; channel 2 gain = 120.3 unit 1, channel 3 gain = 100.2; all channel’s filter = ON 1:3:GAIN=100.2;0:FLTR=1\r\n General Query Response Format Unit#:Cmd:Ch#=<value>{;...
Page 32
MODEL 483C41 GENERAL OPERATION MANUAL Gain = FSO*1000/(FSI*SENS). If a Sensitivity is entered that caused the gain to exceed the amplifiers capability the FSI component will be adjusted to keep the equation valid. Setting: 1:0:SENS=20.2\r\n (unit 1,all channels transducer sensitivity set to 20.2) Setting Response: 1:SENS:ok Query: The SENS query returns the channels transducer sensitivity...
Page 33
MODEL 483C41 GENERAL OPERATION MANUAL Global FSCO Query: 1:0:FSCO? Global FSCO Response: 1:FSCO:1=10.0;2=10.0;3=10.0;4=10.0; INPT The INPT command sets the input mode for a given channel. The mode selection is sent as an integer value. The possible input modes and their associated values are: ...
Page 34
MODEL 483C41 GENERAL OPERATION MANUAL 6=100 Hz Setting: 1:1:FLTR= 1\r\n ( unit 1, channel 1, Input Filter Enabled; Corner=30 kHz) Setting Response: 2: FLTR:ok Query: The FLTR query returns the channels Output Filter. Query Format: Unit#:Ch#:CMD? Response format: Unit#:Cmd:Ch#:= <0-6>; Query 1:1:FLTR?;...
Page 35
MODEL 483C41 GENERAL OPERATION MANUAL Global CALB Response: 1:CALB:1=1;2=0;3=0;4=0;\r\n RTED The RTED query returns the TEDS information that is stored in the sensor or other, TEDS capable, in-line module attached to a specific channel. The signal conditioners are IEEE 1451.4 compliant in that they will read the DS2430A Application Register Status to see if it indicates the 64 bit Application Register has data in it.
Page 36
MODEL 483C41 GENERAL OPERATION MANUAL Setting: N/A – Command is Read only Query: This command is a global command and will return all channel bias readings regardless of the channel id in the command. Query Format: Unit#:Ch#:RBIA? Response format: Unit#:Cmd:Ch#:=CH1 bias;… CHn#:=CHn bias; Query: 1:1:RBIA? Query Response: 1:RBIA:1= 25.5;2= 25.5;3= 25.5;4= 25.5;...
Page 37
MODEL 483C41 GENERAL OPERATION MANUAL OPT_GAIN_INC 0x10 Incremental Gain Input Options OPT_INP_CIM 0x02 ICP|VOLT|CHG OPT_INP_INTCAL 0x08 Internal Cal Filter OPT_FILTER_OUT 0x02 Output filter (optional) OPT_FILTER_PGM_BTR 0x10 Programmable Butterworth LP filter Miscellaneous Options OPT_MISC_TEDS 0x04 TEDS OPT_MISC_IEXC 0x08 current excitation More Miscellaneous Options OPT_MISC2_NOPWR 0x80 No Soft (logical) Power Button...
Page 38
MODEL 483C41 GENERAL OPERATION MANUAL Setting: 2:1:LEDS= 0\r\n ( unit 2, channel 1, Any value ) Setting Response: 2:LEDS:ok Query: RSET The RSET command is used to restore the factory default channel settings. This command invokes a function and therefore has no query capability. Setting: 2:1:RSET = 0\r\n ( unit 2, channel 1, Any value )
Page 39
MODEL 483C41 GENERAL OPERATION MANUAL <Unit>:<Cmd String>:-2<CR> <LF> Channel Error. The channel number in the command is invalid. <Unit>:<Cmd String>:-3<CR> <LF> Command Error. The command is not recognized. <Unit>:<Cmd String>:-4<CR> <LF> Unit Error. The unit number in the command is invalid. <Unit>:<Cmd String>:-5<CR>...
Page 40
Model Number Revision: E EIGHT-CHANNEL ICP®/VOLTAGE/CHARGE SENSOR SIGNAL CONDITIONER 483C41 ECN #: 49172 Performance ENGLISH OPTIONAL VERSIONS Channels Optional versions have identical specifications and accessories as listed for the standard model ICP®, Voltage, Sensor Input Type(s) ICP®, Voltage, Charge except where noted below. More than one option may be used. Charge Gain(ICP®/ Voltage Input) 0.1 to 200...
Page 41
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. REMOVED EXT CAL INPUT CONNECTOR 42318 EXTERNAL AC POWER INPUT AND FUSE...