Download Print this page

RCT SMARTRACK GLOBAL VDI 4458 Installation Manual

Advertisement

Quick Links

INSTALLATION GUIDE
®
SMARTRACK
GLOBAL VDI 4458
www.smartrackglobal.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the SMARTRACK GLOBAL VDI 4458 and is the answer not in the manual?

Questions and answers

Summary of Contents for RCT SMARTRACK GLOBAL VDI 4458

  • Page 1 INSTALLATION GUIDE ® SMARTRACK GLOBAL VDI 4458 www.smartrackglobal.com...
  • Page 2 RCT provides the document to you on an ‘as is’ basis. RCT is not required to provide any updates to this version of the document. RCT may make any change, amendment, or modification to the contents in this document without notice to you.
  • Page 3 Contents Overview Installation Guide Kit Contents Mounting of Hardware – Telematics Module – Display Unit – Antenna – Impact Sensor – Loom – Weight Feature Battery Supply Connection VDI 4458 Gateway Connection System Test ® SmarTrack Global VDI 4458 External Wiring (717h) Installation and Commissioning Wizard –...
  • Page 4 Figure 2 Identification of Antenna Lead Connections on Fleet Controller ............6 Figure 3 VDI 4458 Gateway Connection Block Diagram ................. 7 Figure 4 Drawing 717h – SmarTrack Global VDI 4458 External Wiring ............8 4 | 18 M1298.docx | Rev 1.5 | Modified on 16/10/2023 | © Remote Control Technologies Pty Ltd...
  • Page 5 3. Download the SmarTrack Product Manual and Installation and Commissioning Wizard instructions as required. If you have difficulties logging in or downloading, please contact your company’s internal SmarTrack product administrator first. If you still experience issues, email smartracksupport@rct-global.com. Installation Guide Kit Contents Part No.
  • Page 6 3. The antenna must be no closer than 500 mm to the 11505 or 15589 module. 4. The antenna connectors are different so take care to mate the correct plug. 5. Tighten using an SMA finger wrench (RCT part number 10472). Do not over-tighten - FINGER TIGHT ONLY.
  • Page 7 Weight Feature If the optional weight feature is used, an additional pressure sensor and associated hydraulic fittings will be required—a suitable sensor kit for this is RCT part number 15917. Battery Supply Connection The SmarTrack VDI 4458 loom requires connection to a battery source. The power output from the VDI 4458 gateway, as per the VDI 4458 standard, is not sufficient to power the SmartTrack system.
  • Page 8 ® SmarTrack Global VDI 4458 External Wiring (717h) Figure 4 Drawing 717h – SmarTrack Global VDI 4458 External Wiring 8 | 18 M1298.docx | Rev 1.5 | Modified on 16/10/2023 | © Remote Control Technologies Pty Ltd...
  • Page 9 Installation and Commissioning Wizard Language Selection Select the language you wish to use while completing the commissioning wizard. Note This language selection only commissioning wizard. The operator language is controlled from the web portal. Communications Check and Updates ® The wizard will check the network connection between the machine and the SmarTrack server.
  • Page 10 VDI 4458 Machine Selection Select the machine type from the list, and then select VDI-4458. Do not use the Momentary Switch type with the VDI 4458 interface selected as this is unsuitable for this interface. Select Latched Switch if the VDI 4458 interface VCC+ is OFF when the key switch is OFF.
  • Page 11 System Relay Testing This will allow the testing of the system relay circuits. The activation, aux, and zoner relay circuits can be tested. Note The testing of the activation relay will apply power to the machine. Ensure the machine is safe to operate and you are prepared.
  • Page 12 Testing Access Control and Impact Sensor Hold an access card to the display to test the swipe card function. The code from the card will be displayed. The impact sensor testing checks connectivity of the sensor only. Test Review Ensure that the tests have been verified by the presence of a green tick mark.
  • Page 13 Appendix Communications Check for Wi-Fi Versions 1. Communications Screen To connect to your Wi-Fi, you must change the SSID and password to your network credentials. Press the button to edit the communications settings. 2. Setting the Access Point Press the button to enter the Access Point (AP) setting.
  • Page 14 5. Press the buttons to scroll up or down the list to select the SSID you want. Press the button to select your choice of access point. Continue to step 7. 6. Enter the SSID using the onscreen keyboard. (Use the navigation buttons to move the cursor to the character or key you want and press the button...
  • Page 15 Controller ID SmarTrack Controller serial number. ® ControlMaster The Automation and control technology product brand of RCT. Critical Impact An impact that happens on the machine that is equal to above the critical impact threshold configured. Critical Output Feature to notify operator when an unexpected failure/output occurs during operation of the machine.
  • Page 16 An electrical switch circuit that returns to its previous state after being actuated. For example, a horn button. ® Muirhead The machine and personnel protection product brand of RCT. Normally Closed (N/C) Switch contacts in a circuit are normally closed in their OFF state. Normally Open (N/O) Switch contacts in a circuit are normally open in their OFF state.
  • Page 17 Warranty Please see the RCT standard warranty, available on our website - www.rct-global.com Revision History Date Details of change 19/03/2021 LesH Initial document draft and approval. 31/03/2022 Updated Installation Guide section. Added Appendix. 11/05/2022 LesH Updated Battery Supply Connection, System Test and VDI 4458 Machine Selection sections.
  • Page 18 Discover more: www.rct-global.com sales@rct-global.com AUSTRALIA: +61 (0) 8 9353 6577 AFRICA: +27 (0) 83 292 4246 CANADA: +1 705 590 4001 RUSSIA / CIS: +7 (910) 411 11-74 SOUTH AMERICA: +56 3 5229 9409 USA: +1 801 938 9214...