Download Print this page
LifeBasis PTH-5 User Manual

LifeBasis PTH-5 User Manual

Carbon dioxide monitor

Advertisement

Quick Links

CARBON DIOXIDE
MONITOR
PTH-5 USER MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the PTH-5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LifeBasis PTH-5

  • Page 1 CARBON DIOXIDE MONITOR PTH-5 USER MANUAL...
  • Page 2 Please read this manual carefully before using the product and keep it properly. Thank you for purchasing the carbon dioxide monitor PTH-5! This product uses a carbon dioxide sensor based on the principle of non-dispersive infrared absorption, which can accurately measure the concentration of carbon dioxide in the air with a concentration range of 0 ppm to 5000 ppm.
  • Page 3 Make sure the product is fully charged and use the product after calibration. If the problem still cannot be resolved, please contact customer service: contact@lifebasis.com. Special statement: The illustrations of the products, accessories and user interface in the manual are all schematic diagrams and are for reference only.
  • Page 4 2.Charging and Battery Life 1.Use USB cable with a 5V, 1A adapter, in general, it takes 4-6 hours to fully charge. (This data is for reference only, the actual time will be affected by various factors) 2.Battery Life: Continuously use of the display, it can be used for 24 hours. While standby state (non-continuous use of the display), can be used for 36 hours.
  • Page 5 4.Button Button Operation PTH-5 press and hold for 3 seconds Power on / off Press Switching temperature units between ℃&℉ Set screen state: screen backlight press and hold for 3 seconds Press Place it in a ventilated place, press the A...
  • Page 6 5.Alert Whether the Carbon dioxide value exceeds the standard is indicated by the expression icon and indicator light, as shown in the following table: Normal Good When the measured value is between 0-700ppm, the Carbon dioxide value belongs to the safe range; When the measured value is between 700-1500 ppm, the Carbon dioxide value belongs to the warning range and needs close observation;...
  • Page 7 You can also directly judge whether the formaldehyde value exceeds the standard through the indicator light. The following is the comparison table of indicator light color and its meaning: Light Meaning Green Good Yellow Normal 6.Specifications The following table provides the specifications of the measurement parameters PTH- 5 Specification -10~40°C(±1°C)
  • Page 8 Notice 1.This product should not be dipped in water, nor should it be placed in a high temperature environment exceeding 60℃. 2.This product belongs to precision measuring instrument and shall not be dismantled without authorization. 3.It can not be measured in the environment of organic gas with too high concentra- tion for a long time.