  • Page 1 BRITA VIVREAU TOP SERIES EN Original operating manual...
  • Page 2 GENERAL INFORMATION VIVREAU TOP SERIES The VIVREAU Top series BRITA HygienePlus This instruction manual is valid for the following products: The VIVREAU Top product range BRITA HygienePlus is an exclusive includes three performance options: 3 zone protection, only available at...
  • Page 3 SAFETY INSTRUCTIONS Important safety instructions. Please read these safety • In the case of a suspected in- the immediate vicinity of the instructions carefully before using the appliance. Keep crease in CO concentrations, bottle. this manual in a convenient place so you can always refer to it do not breathe in, exit the dan- •...
  • Page 4 SAFETY INSTRUCTIONS Do not pull the plug out of the • The water dispenser must be • Always be aware of hygiene at • Only permit qualified persons mains, as this can become a placed on a level surface that the installation location.
  • Page 5 SAFETY INSTRUCTIONS Manufacturer A user is designated as any per- may only be carried out by Safety equipment Certain work may only be per- son who uses the appliance for qualified persons. formed by the personnel of the dispensing water. •...
  • Page 6 • Only use original spare parts The following environmentally from BRITA GmbH or spare hazardous substances are used: parts approved by BRITA Refrigerants could contain GmbH. The device must be...
  • Page 7 In the event that public authorities For more information, see “Safety • CO leakage request that the mains water must Instructions”, page 4-13. • Electric shock be boiled, this also applies to BRITA Technical data filtered water. USED SYMBOLS STORAGE Identification plate Dismantling and disposal...
  • Page 8 The switch lights up. qualified person. For the floorstanding version (coun- tertop + base cabinet) BRITA recom- mends to mount the base cabinet to the wall. 1. Select desired portion size Please contact customer service for (glass or bottle) more information (see rear page).
  • Page 9 USING THE DEVICE MENU STRUCTURE Please observe the foldout page! Errors and Warnings Standby All settings can only be executed by the operator or the service technician. I. VIVREAU Top The display enters standby mode System Setup when not in use for more than 5 min- Enter menu Swipe downwards with two fingers on the display.
  • Page 10 USING THE DEVICE Only for operator or service technician Available water temperature setting modes Detailed information about the device • Coldest • Device type • Colder • Device hardware/revision • Cold • Device serial-no • Electronic hardware version/revision Portion sizes •...
  • Page 11 SETTINGS MAINTENANCE Only for operator or service technician Schedule Portion Settings Temperature setting For the optimum and trouble-free If increased wear is identified during It is possible to preset two different portion sizes The water temperature operation of the water dispenser, routine checks, the required intervals for each water type.
  • Page 12 MAINTENANCE Please observe the foldout page! Cleaning Disinfecting the outlet tap Cleaning the ventilation grilles Check the CO bottle I. VIVREAU Top WARNING! WARNING! 1. Pull the drip tray 1. Clean the Danger to health from Never cover up the ventilation Check the fill level of the CO (3) out towards you stainless steel...
  • Page 13 REPLACING CO GAS BOTTLE Safety instructions for using CO gas cylinders. 12 steps to change the CO cylinder safely: Not following these instructions may lead to serious or fatal injuries! 1. CO bottle is empty (check E2 for 9. Tighten nut F with spanner. En- Always connect the CO cylinder to Danger! CO...
  • Page 14 INACTIVE PERIODS Before inactive periods longer than 3 days After longer inactive periods Before the water dispenser is due to experience an inactive period of more than After an inactive period longer than 24 hours or a power failure, clean the tap, 3 days, proceed as follows: housing and drip tray with antibacterial wipes and disinfectant spray, reconnect the water supply and open the CO...
  • Page 15 TROUBLESHOOTING Response to possible problems Problem Cause Remedy If problems occur, the dispenser will show relevant information and problem- Water is warm Water temperature Contact the operator to set solving hints. If the problem cannot be solved immediately, please contact incorrectly set the water temperature customer service (see rear page).
  • Page 16 WHAT TO DO IN AN EMERGENCY Water leakage 1. Disconnect the 2. Shut off the water dispenser water supply and from the power collect the leaked supply. water. Refrigerant leakage WARNING! 1. Open doors 2. Switch off the Danger to health 3.
  • Page 17 TECHNICAL DATA IDENTIFICATION PLATE The identification plate is on the back VIVREAU TOP Series VIVREAU Top 50 VIVREAU Top 85 of the appliance. Cooling Performance 50 l/h 85 l/h Flow rate 2 l/min 2 l/min Voltage 230 V 230 V Current, max.
  • Page 18 BRITA Vivreau GmbH BRITA France SARL Neugablonzer Straße 1 52 boulevard de l’Yerres 93073 Neutraubling 91030 EVRY Cedex Deutschland France Telephone: +49 9401 607 100 Telephone: +33 1 69 11 04 24 Telefax: +49 9401 607 222 Email: pro-fontaine@brita-france.fr service-wasserspender@brita.net www.fontaine.brita.fr...

This manual is also suitable for:

Vivreau top 50Vivreau top 50 hygieneplusVivreau top 85Vivreau top 85 hygieneplusViv t 50 c2-tg-iViv t 50 m-c2-tg-j ... Show all
Save PDF