CSK-320
Quick Start Guide
CS-3000 Front Panel
5
2
12
9
10
1.
RF ON/OFF button
2.
Power Up/Down buttons,
Set and Actual Power
3.
Time Up/Down buttons,
Set and Elapsed Time
4.
Mode button
5.
Generator Graphical Display
6.
Standby LED indicator
*Cables connected include CSK-2000, CSK-2060, or CSK-2030
1
4
6
7
3
8
1
11
7.
Error LED indicator
8.
RF ON/OFF LED indicator
9.
Cable connector*
10.
Indifferent, Dispersive
Electrode (Return electrode
or Ground Pad) connector
11.
Footswitch connector
12.
Impedance
CS-3000 Back Panel
15
16
14
13
13.
Power Switch
14.
AC Power Connector
15.
Grounding Stud
(Equipotential Connector)
16.
Data Connector/Port
17.
Alarm Volume Control
en | 2024/11 | IFU-0440.A
17

Advertisement

loading
Need help?

Need help?

Do you have a question about the nContact CS-3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AtriCure nContact CS-3000

  • Page 1 CSK-320 Quick Start Guide CS-3000 Front Panel CS-3000 Back Panel RF ON/OFF button Error LED indicator Power Switch AC Power Connector Power Up/Down buttons, RF ON/OFF LED indicator Set and Actual Power Cable connector* Grounding Stud Time Up/Down buttons, (Equipotential Connector) Indifferent, Dispersive Set and Elapsed Time Data Connector/Port...
  • Page 2 CS-3000 Connections EPi-Sense family of Devices Sterile RF Cable en | 2024/11 | IFU-0440.A...
  • Page 3 POWERING UP THE CS-3000 WARNING CONNECT COMPONENTS AND DEVICES TO THE ELECTROSURGICAL UNIT ONLY WHEN RF ENERGY IS OFF. FAILURE TO DO SO MAY RESULT IN AN INJURY OR ELECTRICAL SHOCK TO THE PATIENT OR OPERATING ROOM PERSONNEL. USE GLOVES WHEN OPERATING THE CS-3000 Connect the provided power cord to the back of the CS-3000.
  • Page 4 REMEDY • Reconnect or replace handpiece • On Screen: Invalid Device • If the problem persists, contact AtriCure Customer Service • Meaning: Device identification code is outside the acceptable range • Check the return electrode connector, return electrode, and reposition the return electrode •...
  • Page 5 • If the problem persists, contact AtriCure Customer Service For additional information on the Warnings, Cautions, and Faults, see the CSK-320 Instructions for Use For other concerns or detailed information, consult the CSK-320 Instructions for Use or contact the AtriCure Customer Service Hotline at (866) 349-2342.
  • Page 6 AtriCure Inc. 7555 Innovation Way Mason, Ohio 45040 USA +1 866 349 2342 +1 513 755 4100 en | 2024/11 | IFU-0440.A...
  • Page 7 CSK-320 Guide de démarrage rapide Panneau avant du CS-3000 Panneau arrière du CS-3000 ÉTIQUETAGE DU PRODUIT Bouton RF ON/OFF Voyant LED Standby Interrupteur d’alimentation Connecteur d’alimentation CA Boutons d’augmentation Voyant LED Error et de diminution de la Voyant LED RF ON/OFF Goujon de mise à...
  • Page 8 Connexions du CS-3000 Gamme de EPi-Sense dispositifs family of EPi-Sense Devices Câble RF stérile Sterile RF Cable  1 = D1  2 = D2 CS-3000  3 = P1  4 = P2 CSK-2030 fr | 2024/11 | IFU-0440.A...
  • Page 9 MISE SOUS TENSION DU CS-3000 AVERTISSEMENT NE CONNECTEZ LES COMPOSANTS ET LES DISPOSITIFS À L’UNITÉ ÉLECTROCHIRURGICALE QUE LORSQUE L’ÉNERGIE RF EST DÉSACTIVÉE. LE NON-RESPECT DE CETTE CONSIGNE PEUT ENTRAÎNER UNE BLESSURE OU UN CHOC ÉLECTRIQUE POUR LE PATIENT OU LE PERSONNEL DE LA SALLE D’OPÉRATION. UTILISEZ DES GANTS LORSQUE VOUS UTILISEZ LE CS-3000.
  • Page 10 REMÈDE • Reconnectez ou remplacez la pièce à main • À l’ é cran : Invalid Device • Si le problème persiste, contactez le Service clientèle d’AtriCure • Signification : Le code d’identification du dispositif est en dehors de la plage acceptable •...
  • Page 11 • Coupez et remettez l’alimentation en marche • À l’ é cran : RF POWER TOO HIGH WHEN OFF • Si le problème persiste, contactez le Service clientèle d’AtriCure • Signification : Générateur affichant et émettant une puissance supérieure à 0 W lorsque la RF est désactivée •...
  • Page 12 AtriCure Inc. 7555 Innovation Way Mason, Ohio 45040 États-Unis +1 866 349 2342 +1 513 755 4100 fr | 2024/11 | IFU-0440.A...