Summary of Contents for BENIFERRO Pool Twin Display
Page 1
Pool Twin display water treatment using liquid chlorine...
Page 2
Installation ......................7 Maintenance and inspection .................. 20 Troubleshooting ....................22 Switching Your Pool Twin Display from Read-Only Mode to Normal Mode ....28 Steps to Switch from Read-Only Mode to Normal Mode: ..........28 What to Expect After Switching ................... 29...
Page 3
[Type here] INTRODUCTION This WiFi pool set contains all components to measure and regulate pH and Redox (liquid chlorine). The peristaltic pumps start and stop according to the automations defined via the display WiFipool app. You can start your pH or RX control pump based on the pH and your chlorine pump based on the measured Redox.
Page 4
[Type here] Electrical • Disconnect all power supplies during installation or during any other operation on the equipment. • It is recommended that the water treatment unit be installed in a bypass configuration so that: o Chlorine and acid pumps cannot operate if the filtration pump is not working. This can be done by purchasing a metering device with a flow switch, adding a flow switch to the facility, or using the same or shorter timer than the filter pump.
Page 5
• To ensure proper operation of peristaltic pumps, check the pumps weekly for leaks. In case of leaks, please refer to the complete manual of your installation on www.beniferro.eu • Ensure that the measuring probes remain consistently moist during transportation, especially when being transported for maintenance or repair work at the supplier's facility.
Page 6
[Type here] During the pool's initial fill, adjusting pH and chlorine levels may take several hours to days. It's vital to perform calibrations and measurements during this start-up phase. Inadequate grounding of the pool installation can adversely affect measurement accuracy, resulting in abnormal pH and chlorine readings.
Page 7
[Type here] INSTALLATION Installation of the water treatment panel 1) Attach the water handling unit to a solid wall. Attach both the lower and upper part of the panel. 2) Place the pH and chlorine electrodes in the electrode holders. Tighten the nut with pliers or a wrench to tighten the cap.
Page 8
[Type here] 4) Adjust the electrical connections so that - The chlorine and acid pumps cannot work if the filter pump does not work, via the menu item Flow switch (on). - Of chlorine- in acid pumps can become disabled when of filter pump in action is. Filter pump Fuse with timer...
Page 9
[Type here] the electrode holders to prevent water from leaking from the electrode holders during calibration. (2) If you have a bypass, make sure that the dosing pumps cannot pump liquid when the bypass to the dosing nipples is closed. This can be done by switching off the dosing pumps themselves or by switching off the power supply (3) Calibrating the electrodes may take a few minutes.
Page 10
[Type here] <- A timer stops after 120 seconds and indicates whether the calibration was successful If the calibration is not successful, the following message is displayed -> Reasons for a failed calibration: - Poor calibration (try again) - The calibration fluid is contaminated (replace the liquid). Recalibrate - Probe defective (replace the probe) and recalibrate.
Page 11
[Type here] 11 Set parameters A number of parameters need to be set. Press the center button. You will see the following screen: 11.1) Language You can set a (different) language. Press the middle button again. Then use the top or bottom button to navigate to the languages Français, Castellano, Italian, English, German.
Page 12
[Type here] - The pumps always run if pH and/or redox setpoint are not reached. - If you decide to use this dosing method, the injection point for pH and chlorine should be at least 2 metres apart. First, adjust the pH for at least 5 minutes. •...
Page 13
[Type here] As a rule, the pH value is set to 7.4. 11.5) Rx SP (Redox SetPoint) The redox is a measure of the chlorine content. During commissioning, we recommend setting the set point to 700 mV, as described above for the pH value. After the first commissioning, measure the chlorine content using a colour method.
Page 14
[Type here] - Redox too low (<100) - Rx Setpoint not reached make 400 minutes dosage The alarm function is necessary to warn the user of abnormal behaviour of the unit and to prevent a very large dose of a pH liquid from being dosed or from dosing or generating too much chlorine.
Page 15
[Type here] For example, the pH value can be very high and the Rx value very low when the pool is first put into use. In this case, you need to use the alarm function "OFF" to check the pH and chlorine. When the "alarm off"...
Page 16
[Type here] setpoint should be lowered. If it is determined that the chlorine content is too low, the Rx setpoint should be increased. If necessary, repeat this procedure several times until the chlorine content remains constant between 1 and 1.5 ppm. As an extra safety measure, we recommend that you do not lower the suction cup to the bottom of the jerry can when starting.
Page 17
[Type here] - A simple measurement with droplets or strips does not give reliable results : Reliable measurements have to be done using a Poollab or equivalent instrument Here are the steps to follow in case of doubt about the pH: In case of opposite pH measurement (one method gives an acidic result, the other method gives a basic result): Take a glass of water and add 2 tablespoons of vinegar.
Page 18
[Type here] If you still have doubts about the redox value you have read, you can proceed as follows: 1 Change calibration fluid and recalibrate the device. If you still have doubts about the redox value read: 2 Exchange redox probe and recalibrate. Table 1 The following table shows the ratios between mV, pH and the corresponding chlorine content in ppm.
Page 19
[Type here] Flow Switch When a flow switch is added to the equipment, it will stop the dosing operation as soon as no flow is detected. To obtain this feature, the Flow switch has to be in the „YES“ position in the menu.
Page 20
[Type here] When a low level is detected, the pump involved stops pumping and an alarm is generated, provided the option “level switch” in the menu is set to YES. Winter-ready Be careful! If you do not protect your product from the winter, this can lead to damage that is no longer covered by the warranty.
Page 21
[Type here] Maintenance of peristaltic pumps The pump hose has reached the end of its service life after 500/600 operating hours (chemical compatibility) and must be replaced annually The hoses of the drain and supply pipe must be replaced every two years. The nozzles must be descaled and rinsed every two years.
Page 22
[Type here] Note: Very important 1. Always turn off the device if it has been repaired or maintained. 2. When sending the device for inspection, make sure that the measuring probes are always in a storage liquid when you send them. If the measuring probes are dry for 3 to 4 hours, this may affect the following measurements and lead to incorrect measurements.
Page 23
[Type here] Relays remain on Contact the supplier. Acid or Chlorine pump only doses The acid / Chorine dosing No action required occasionally method is set to “proportional” Chlorine pump does not dose Switch under the dosing pump is Set the switch to "1" set to "O"...
Page 24
[Type here] Santoprene dosing hose leaks Check if the dosing nipple is clogged and replace the dosing tube. Leak in Chlorine injection part Injection nipple blocked by Replace injector, adding a (between peristaltic pump and scaling flexible tube of 5-10 cm to injection) the injection outlet.
Page 25
[Type here] 3. Faulty display or display circuit board: If the pumps operate after disconnecting, but the unit still does not function properly, the problem may be with the display or the entire display circuit board. Water becomes green/ not correct pH or Chlorine content not Verify values with Poollab or water quality...
Page 26
[Type here] Extra info for problem: The unit no longer functions : display remains black Summary : Open the unit and disconnect the two circuit boards. The pH and RX pumps should start after disconnecting. Steps: To disassemble: a. Turn off power b.
Page 27
[Type here] If the pumps turn, there is someting worng with the display print plate. This can be a fatal print plate error, or just a broken display. You can test via the service menu. If the relay works, the system works. If the relay is not functioning, connect a wire from the pH pump going to the relay directly to the power.
Page 28
Pool Twin display can only read values without making any changes. This mode is often activated accidentally. To reset the Pool Twin display and switch it back to normal mode, follow these steps: Steps to Switch from Read-Only Mode to Normal Mode: 1.
Page 29
[Type here] Once these steps are completed, the device should operate in normal mode. What to Expect After Switching Upon starting, if the system is still in read-only mode, you will see a screen indicating this status. In read-only mode, the device only measures values and does not control any functions. Operational Guide for Peristaltic Pumps and Salt Electrolysis Control Systems The degree of activity of the peristaltic pump and/or salt electrolysis can be seen on the control...
Page 30
In case of salt electrolysis : press the ON/Standby bottom once. If the pump / salt electrolysis still does not start, contact your supplier or the manufacturer. Manufacturer Beniferro B.V. Industrieweg 9 3190 Boortmeerbeek Belgium +32 476 965919 info@beniferro.eu...