Page 2
Germany This document and extracts of it may only be reproduced or made available to third parties with the explicit authorization of Franka Emika GmbH. The content of this document has been carefully checked against compliance with the hardware and software described. However, discrepancies cannot entirely be ruled out, which is why we assume no liability for complete compliance.
Page 3
Panda work - collaboratively - Some features • Risk assessment - Device overview • Practical information on how to use and place Panda research - Scope of delivery and additionally required equipment • Name plates and warnings TECHNICAL DATA DELIVERY & TRANSPORT •...
Page 4
START-UP • Switching on • Connecting a user interface device • Software-setup • Guiding • Testing the emergency off system • Switching off INTERACTION & PROGRAMMING • Direct human-robot interaction • Creating Tasks in Desk - Desk overview - An App for everything - Configuring Apps - Parametrizing •...
Page 5
CAUTION indicates that nonobservance of instructions or measures may lead Therefore: to minor injury. Panda research may only be used in perfect technical condition, for its intend- ed purpose and within the technical specifications and operating conditions, with awareness of safety and possible dangers...
Page 6
Panda research. Operator The operator of Panda research can be e.g. the entrepreneur, director of the institute, the employer or a delegate responsible for the use of Panda research. The operator is responsible for compliance with regulations of occupational health and the operational safety ordinance.
Page 7
2006/42/EG and therefore does not comply with all of its requirements. There- • use as climbing assistance or leaning against the robotic arm fore, the operator is prohibited from using or marketing Panda research or parts • use in potentially explosive areas of it in terms of the Machinery Directive.
Page 8
For the commercial version of Panda research, safety-rated functionalities for increasing user safety will be provided. The functionalities for user safety presented for the version Panda research cannot be used as “safety-rated functionalities for the safeguarding of persons” (according to Performance Level d and category 3 of EN ISO 13849-1:2008).
Page 9
Dead weight WARNING WARNING Panda research may only be used in perfect condition, according to its The Arm weights approx. 18kg, the Control approx. 7kg, the Hand approx. 1kg. intended purpose and with possible dangers and risks in mind. Misuse can Due to the dead weight and partly geometric design (e.g.
Page 11
PC A PC workstation can optionally Control Interface (FCI), Hand and be connected to the Control via Pilot form the Panda research sys- Ethernet. A workstation is required tem, hereinafter simply referred to for using the real-time interface FCI as Panda of Panda research.
Page 12
Betreiber operator The operator of Panda research can Notentriegelung emergency Emergency unlocking is the process unlocking of using the unlocking tool to unlock be for example the entrepreneur, di- the safety locking system in order to rector of the institute, the employer manually move the Arm.
Page 15
The system was developed based on the globally leading German robot technology, and is now produced in series in Allgäu, Bavaria. Panda research has been ready for use for the research community since August 2017; later in 2017 it will also be ready for use in industry, and this is only the beginning of a new generation of universal tools.
Page 16
Panda research Panda research is our sensitive and extraordinarily versatile power tool for research.The torque sensors in all seven axes enable Panda research to skill- fully and delicately manipulate objects. It also enables the user to directly and intuitively interact with the Arm. Using the specially developed programming paradigm, the lightweight robotic system is easy to set up and use, despite its numerous and highly complex capabilities.
Page 17
The Cartesian movement of a robot Virtual walls Our Panda research arm has numerous position sensors in order to identify the always depends on the reference coordinate system, which can be configured for actual positon of the Arm in space.
Page 18
• Between the Control and the power supply there is an emergency off instal- lation that will cut the power to Panda research in case of emergency. • At the base of the Arm an external activation device is connected, in order to deliberately activate movements of the Arm.
Page 29
• free from aggressive media Therefore: • free from corrosive substances • make sure that the connection of Panda research will not lead to an • free from “flying parts” overload of the electrical installation • free from spraying liquids •...
Page 30
NOTE If a fuse in the upstream power supply of the Control blows, Panda research is disconnected from the power supply. The Arm reacts with braking as much as possible before the fail-safe locking bolts catch in the 7 axes. If the resi- dual energy is not sufficient to bring the Arm to a full stop, the locking bolts may damage the Arm.
Page 32
WARNING Persons using Panda research in any form must be in full possession of their physical and mental powers at all times. Failing this, serious injuries may occur. Cleaning may only be carried out by trained users. For information on the correct...
Page 33
An extensive but not definitive list of dangers that generally may be presen- ted by a robot system can be found under ISO 10218-1:2011 ANNEX A. Spe- cial attention will be drawn here to the following dangers that Panda research may possibly present: •...
Page 35
WARNING the manipulator from the the Arm to the baseplate. Panda research is a research object and therefore does not need to be com- baseplate pliant with all requirements for a provision according to the EU Machinery Directive 2006/42/EG, or the corresponding C-norm for industrial robots ISO Moving of fingers with- When the device is turned off, the Hand is not supplied with power either.
Page 36
• Panda research boots up as soon as the Control has been turned on or is supplied with power. At this point the safety locking system is still active, movements are thus mechanically locked. The signal lights on the base and the Pilot flash yellow.
Page 39
Stopping the robot movement by reaching into the movement, Starting a robot sponds to “automatic mode” as described in EN ISO 10218-1:2012. movement with a gesture such as tapping or similar. Before Panda research can be operated collaboratively, a risk assessment must have been carried out, the result of which must allow for collaborative operation under consideration of the limitations.
Page 40
Furthermore, it is to be made sure that this space is free of obstacles (e.g. cables, objects) to prevent persons from tripping over these obstacles and harming Panda research is a research object and therefore does not need to be com- themselves.
Page 44
This slipping causes decalibration and damage to the Arm. Delivery Panda research is delivered in original packaging. The scope of delivery is de- scribed under /Introduction/This is Panda research. Transport pose Since both the Arm and Control contain sensitive electromechanical compo-...
Page 47
MOUNTING & INSTALLATION Unpacking Panda research Preparing the site of installation WARNING Dead weight The Arm weighs approx. 18kg, the Control approx. 7kg, the Hand approx. 1kg. Correct site of installation Under/Correct Site of Installation/ the most important requirements for the Due to the dead weight and partly geometric design (e.g.
Page 49
Only use the screw types listed in this manual • The screwing depth must not exceed 8mm • Only use Panda research when in perfect technical condition • The installation of the emergency off system may only be carried out by qualified personnel.
Page 50
M5x8 screw with lock washer are to be provided. Connecting the interface To operate Panda research via the intuitive programming interface Desk and using device (for operation via Apps: Connecting the Hand to •...
Page 51
• Never connect or disconnect the Hand before safely disconnecting Panda research from the power supply. Connection to the power supply NOTE The connection cable does not support being folded, rolled over or stepped on.
Page 53
This is sup- Switching on Now you may switch on Panda research for the first time: ported by the two status lights on both sides of the base, which has the respective signalcolor, similar to a traffic light.
Page 54
The interface device must obtain the IP address automatically via DHCP. following steps: • Once Panda research has been switched on, the interface device will auto- • To create an admin: In Desk, click on the user name on the right-hand side matically be assigned an IP address.
Page 55
WARNING If you want to use another gripper or adjust the configuration of the Franka If the end effector is configured incorrectly, Panda research will operate based Hand, select “User Defined” from the dropdown and enter the corresponding on the wrong masses and mass inertia ratios of the end effector. This means values into the text fields.
Page 56
Please read the chapters /Safety Concept/ and /Interaction/Programming/ before using guiding mode for the first time. Not using it correctly may cause serious injury and/or material damage! Unlocking the safety Before Panda research can be moved you need to unlock the safety locking locking system system: •...
Page 57
Testing the emergency off system NOTE As soon as the control is no longer supplied with power, Panda research is The emergency off system must be activated and tested for functional capa- safely stopped and mechanically locked by the fail-safe safety locking system.
Page 59
Using the disc on top of the Pilot, different entries for programming can be with each other to offer you intuitive and effective usability for Panda research. made. Disc can be used to navigate in Desk (3), select individual Apps and You can purchase robot apps in the Franka Store and arrange them in Desk to parametrize, e.g.
Page 65
Never carry out an emergency unlock when the Arm is switched on – back and watch) “Play” button in Desk. The App currently being executed will be displayed with a Panda research must always be safely disconnected from the power green frame and Panda will start flashing green.
Page 66
Never carry out an emergency unlock when the Arm is switched on – Arm on joint level. The stiffness for each joint can be defined Panda research must always be safely disconnected from the power here. The lower the value, the softer and more compliant the supply before an emergency unlock.
Page 72
Control. Then the browser window for Desk can be closed as well. Shut-down, storage and disposal Disposal Shut-down, storage and disposal of Panda research may only take place according to the relevant country-specific laws, standards and regulations. Battery The Control contains a coin cell battery. This battery is to be disposed of sepa- rately according to the relevant country-specific laws, standards and regulations.