Download Print this page
ebm-papst K3G250-RF51-10 Operating Instructions Manual
ebm-papst K3G250-RF51-10 Operating Instructions Manual

ebm-papst K3G250-RF51-10 Operating Instructions Manual

Advertisement

Quick Links

K3G250-RF51-10
ASIA PACIFIC SHENGRUI LIMITED
Phone +00852 56261528
info@apacfan.com
www.apacfan.com
CONTENTS
1. SAFETY REGULATIONS AND INFORMATION
1.1 Hazard levels for warnings
1.2 Staff qualifications
1.3 Basic safety rules
1.4 Voltage
1.5 Safety and protective features
1.6 Electromagnetic radiation
1.7 Mechanical movement
1.8 Emissions
1.9 Hot surface
1.10 Transport
1.11 Storage
2. INTENDED USE
3. TECHNICAL DATA
3.1 Product drawing
3.2 Nominal data
3.3 Data according to Commission Regulation (EU) 327/2011
3.4 Technical description
3.5 Mounting data
3.6 Transport and storage conditions
3.7 Electromagnetic compatibility
4. CONNECTION AND STARTUP
4.1 Mechanical connection
4.2 Electrical connection
4.3 Connecting the cables
4.4 Connection diagram
4.5 Checking connections
4.6 Switching on the device
4.7 Switching off the device
5. INTEGRATED PROTECTIVE FEATURES
6. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
6.1 Cleaning
6.2 Safety inspection
6.3 Disposal
Item no. 55828-5-9970 · ENU · Change 224093 · Approved 2021-02-10 · Page 1 / 11
Operating instructions
1. SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1
1.1 Hazard levels for warnings
1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
2
3
4
4
5
5
5
6
6
1.2 Staff qualifications
6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
6
Only authorized specialists are permitted to install the device, to carry
7
out a test run and to perform work on the electrical installation.
8
9
1.3 Basic safety rules
9
9
The safety hazards associated with the device must be assessed again
following installation in the final product.
9
The locally applicable industrial safety regulations are always to be
observed when working on the device.
9
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
10
Note the following when working on the device:
10
; Do not perform any modifications, additions or conversions on the
10
device without the approval of ebm-papst.
1.4 Voltage
; Check the device's electrical equipment at regular intervals; see
Chapter 6.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

loading
Need help?

Need help?

Do you have a question about the K3G250-RF51-10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst K3G250-RF51-10

  • Page 1 Note the following when working on the device: 6.2 Safety inspection ; Do not perform any modifications, additions or conversions on the 6.3 Disposal device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 6.2 Safety inspection.
  • Page 2 Operating instructions K3G250-RF51-10 WARNING WARNING Live terminals and connections even with device Rotating device switched off Long hair and dangling items of clothing, jewelry and the like Electric shock can become entangled and be pulled into the device. Injuries can result.
  • Page 3 Operating instructions K3G250-RF51-10 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4 Operating instructions K3G250-RF51-10 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Cable PVC AWG20, 3x crimped splices Cable PVC AWG22, 4x crimped splices Mounting dimensions Item no. 55828-5-9970 · ENU · Change 224093 · Approved 2021-02-10 · Page 4 / 11...
  • Page 5 If you have special questions, consult ebm-papst for 14 Additional components Components used to calculate the energy efficiency that are not apparent from the support.
  • Page 6 Operating instructions K3G250-RF51-10 3.5 Mounting data 4. CONNECTION AND STARTUP Any further mounting data required can be taken from the product 4.1 Mechanical connection drawing or Section Chapter 4.1 Mechanical connection. CAUTION Strength class of Risk of cutting and crushing when removing device...
  • Page 7 Operating instructions K3G250-RF51-10 CAUTION (RCCB) with a trip threshold of 300 mA and delayed tripping Voltage (super-resistant, characteristic K). The fan is a built-in component and has no disconnecting switch. 4.2.4 Locked-rotor protection → Only connect the fan to circuits that can be switched off with an all-pole disconnection switch.
  • Page 8 Operating instructions K3G250-RF51-10 4.4 Connection diagram Drawing preliminary! Conn. Designation Color Function/assignment CON10 L black Supply connection, power supply, phase, see nameplate for voltage range CON11 N blue Supply connection, power supply, neutral conductor, see nameplate for voltage range CON12 PE...
  • Page 9 Operating instructions K3G250-RF51-10 4.5 Checking connections 5. INTEGRATED PROTECTIVE FEATURES ; Ensure isolation from supply (all phases). The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table. ; Make sure a restart is impossible ;...
  • Page 10 Let the device protection 6 months replacement of cool down. cover for device intactness or In the event of further malfunctions, contact ebm-papst. damage Device for Visual inspection At least every Replacement of damage to 6 months device 6.1 Cleaning...
  • Page 11 Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 55828-5-9970 · ENU · Change 224093 · Approved 2021-02-10 · Page 11 / 11...