ebm-papst K3G250-RR03-H4 Operating Instructions Manual

ebm-papst K3G250-RR03-H4 Operating Instructions Manual

Advertisement

Quick Links

K3G250-RR03-H4
Siemens AG PD LD Nbg.
ASIA PACIFIC SHENGRUI LIMITED
Phone +00852 56261528
info@apacfan.com
www.apacfan.com
CONTENTS
Item no. 55700-5-9970 · ENU · Change 202174 · Approved 2018-12-28 · Page 1 / 12
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
2
3
4
4
5
5
5
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
6
Only authorized specialists are permitted to install the device, to carry
7
out a test run and to perform work on the electrical installation.
8
9

1.3 Basic safety rules

10
10
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
10
increases the risk of accidents.
Note the following when working on the device:
11
; Do not perform any modifications, additions or conversions on the
11
device without the approval of ebm-papst.
11
12

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 6.3 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K3G250-RR03-H4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst K3G250-RR03-H4

  • Page 1: Table Of Contents

    Note the following when working on the device: 6.1 Vibration testing ; Do not perform any modifications, additions or conversions on the 6.2 Cleaning device without the approval of ebm-papst. 6.3 Safety inspection 6.4 Disposal 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 6.3 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions K3G250-RR03-H4 Siemens AG PD LD Nbg. WARNING 1.7 Mechanical movement Live terminals and connections even with device DANGER switched off Rotating device Electric shock Risk of injury to body parts coming into contact with the rotor or → Wait five minutes after disconnecting the voltage at all poles the impeller.
  • Page 3: Intended Use

    Operating instructions K3G250-RR03-H4 Siemens AG PD LD Nbg. 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions K3G250-RR03-H4 Siemens AG PD LD Nbg. 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Terminal strip 0-10 V +10 V Tightening torque 1.2±0.2 Nm Cable diameter min. 6 mm, max. 10 mm, tightening torque 2.5 ± 0.4 Nm...
  • Page 5: Nominal Data

    The year of manufacture is specified on the product's rating label. - Soft start 07 Manufacturer ebm-papst Mulfingen GmbH & Co. KG - Control input 0-10 VDC / PWM Amtsgericht (court of registration) Stuttgart · - Control interface with SELV potential...
  • Page 6: Mounting Data

    With regard to cyclic speed loads, note that the rotating parts of 4. CONNECTION AND STARTUP the device are designed for a maximum of one million load cycles. If you have special questions, consult ebm-papst for 4.1 Mechanical connection support.
  • Page 7: Connection In Terminal Box

    Operating instructions K3G250-RR03-H4 Siemens AG PD LD Nbg. DANGER 4.2.2 Reactive currents Electrical charge (>50 µC) between phase conductor and Because of the EMC filter integrated for compliance with EMC protective earth connection after switching off supply limits (interference emission and immunity to interference), with multiple devices connected in parallel.
  • Page 8: Factory Settings

    When routing the cable, make sure that the cable glands are located at the bottom. The cables must always be routed downward. 4.4 Factory settings Factory settings made for the device by ebm-papst. Mode parameter set 1 PWM control Mode parameter set 2...
  • Page 9: Connection Diagram

    Operating instructions K3G250-RR03-H4 Siemens AG PD LD Nbg. 4.5 Connection diagram Drawing preliminary! Conn. Designation Color Function/assignment 1, 2 green/ Protective earth yellow blue Power supply, neutral conductor, 50/60 Hz black Power supply, phase, 50/60 Hz white 1 Status relay, floating status contact; break for failure, contact rating 250 VAC / 2A (AC1) / min. 10...
  • Page 10: Checking Connections

    Operating instructions K3G250-RR03-H4 Siemens AG PD LD Nbg. 4.6 Checking connections When disconnecting, be sure to disconnect the ground connection last. ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible 5. INTEGRATED PROTECTIVE FEATURES ; Check the cables for proper fit.
  • Page 11: Vibration Testing

    ; If cleaning agents have been used, rinse these off with clean water. ; If severe corrosion is visible on load-bearing or rotating parts, switch In the event of further malfunctions, contact ebm-papst. off the device immediately and replace it.
  • Page 12: Disposal

    Right from the development stage, ecological design, technical safety electronic scrap. and health protection are fixed criteria. The following section contains recommendations for ecological disposal → Please contact ebm-papst for any other questions on disposal. of the product and its components. 6.4.1 Country-specific legal requirements NOTE...

Table of Contents