  • Page 2 Instruction The CB Basic thermostat controls a floor heating system based on a built-in weekly program. You can set individual temperatures for 4 events or 2 events on different days of the week. The default weekly program parameters can satisfy most installations. If your living habits are different, you can update the weekly program parameters in the thermostat or APP.
  • Page 3 Function and Operation 1. On/Off Button 4. Sensor Selection 7. Day and Time 2. Mode 5. Setpoint 8. Touch Key 3. Temperature 6. Event On/Off Press button to turn on or turn off. Temporary Override Temperature Override temperature is a temporary temperature setting in auto mode and has no effect on schedule 4-event program.
  • Page 4 Weekly Program Parameter Setting In the auto mode, the thermostat runs automatically according to the setting parameters of the weekly program. The weekly program parameters contain two major parameters: Schedule and Event. Schedule: Two schedules for a week. 5+1+1: Event parameter is the same Monday to Friday, with separate Event parameters on Saturday and Sunday. 7: Separate Event parameters every day.
  • Page 5 Settings This thermostat also can be used to other application with different setting. It should be set by professional technicians to avoid damage caused by abnormal settings. To Do So: With Active Display, press OK until MODE flashes. Press ▲or▼ to choose settings. Press OK to confirm.
  • Page 6 4.Sensor Selection This thermostat has floor sensor and built-in air sensors to detect room temperature. Therefore, three sensor applications are available: Room: Controls the room temperature based solely on built-in sensors. Floor: Controls the floor temperature based solely on the floor sensor. Room.Limit: Controls the room temperature based on built-in sensors while monitoring the floor temperature to ensure it does not exceed an upper limit.
  • Page 7 8.Readout This thermostat can read the percentage of time that the heating has been turned on within a certain period. Readout Setting: Enter settings. Press ▲ or ▼ to Readout. Press OK. Press ▲ or ▼ to choose 1Day, 30Days or 365Days. Press OK to return to Active Display.