Page 1
Part No. 215658-A August 2003 4655 Great America Parkway Santa Clara, CA 95054 Installing the BayStack 425-24T 10/100/1000 Switch, Software Version 2.0...
Page 2
Nortel Networks NA Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
Page 3
Adequate space at the front and rear of the switch for access to cables. If you are installing a single BayStack 425-24T switch on a table or shelf, make sure the surface will support at least 15 to 20 pounds (7 to 9 kilograms).
Page 4
Package contents B a y S t a c k 11101FA 1 = BayStack 425-24T switch 2 = Rack-mounting hardware: • Rack-mount brackets • Screws for attaching brackets to the switch • Screws for attaching the switch to the equipment rack...
Page 5
Installing the switch on a table or shelf You can install a single BayStack 425-24T switch on any flat surface that can safely support the weight of the switch and attached cables (15 to 20 pounds or 7 to 9 kilograms).
Page 6
Attach a bracket to each side of the switch. Slide the switch into the rack. Insert and tighten the rack-mount screws. The bracket with the round holes goes on the right side of the switch, where the round fan vents are located. Installing the BayStack 425-24T 10/100/1000 Switch...
Page 7
Output transmit data - (TX-) Input receive data - (RX-) Input receive data + (RX+) Output transmit data + (TX+) Input receive data - (RX-) Output transmit data - (TX-) 87654321 4, 5, 7, 8 Not used 9464EA Installing the BayStack 425-24T 10/100/1000 Switch...
Page 8
Pin assignments for the 1000BASE-T MDI and 1000BASE-T MIDI-X Configurations Signal for 1000BASE-T MDI Signal for 1000BASE-T MIDI Connector Pin number Configuration Configuration TP0+ TP1+ TP0- TP1- TP1+ TP0+ TP2+ TP3+ 87654321 TP2- TP3- 9464EA TP1- TP0- TP3+ TP2+ TP3- TP2- Pin assignments in the console port Connector...
Page 9
425-24T switch. The tables describe LED operation for a switch that has completed its power-on self-tests. Note: The push button on the front panel is not active for this release. Figure 1 BayStack 425-24T switch LED display panel Base GBK/Stack Up...
Page 10
There is no activity on this port. Initial switch setup The BayStack 425-24T switch begins switching as soon as you attach network devices and connect the switch to power. To manage the switch over the network or to perform TFTP operations, you must set certain IP parameters.
Page 11
To set the IP parameters: Connect a terminal to the Console port on the switch. Set the terminal protocol as described in Using the BayStack 425-24T 10/100/1000 Switch. Connect the switch to power. After the BayStack logo is displayed, press [Ctrl]-Y to display the Main Menu.
Page 12
Select IP Configuration/Setup (or press i) to display the IP Configuration/Setup menu. Note: The default management VLAN in the BayStack 425-24T switch is VLAN 1. To manage the switch, make sure the network management station is on the management VLAN or is connected to the management VLAN through routers.
Page 13
In-Band Subnet Mask field. This value is based on the class of the entered IP address. In the In-Band Subnet Mask field, enter the IP subnet mask address. In the Default Gateway field, enter the default gateway address. Installing the BayStack 425-24T 10/100/1000 Switch...