Applications
These actuators are used in constant or
variable air volume installations for the
control of return air, mixed air, exhaust,
and face and bypass dampers requiring
up to 310 lb-in (35 Nm) torque.
Technical Specifications - DC24-310 Series Actuator
Actuator Models
Torque
Operating Voltage
Power Consumption
Control Signal
Operational Protection
Control Impedance
Feedback Signal
Dual Auxiliary Switch
Switch Range
Stall Protection
Electrical Connection
Equipment Rating
Manual Override
Runtime for 90°
of Rotation
Rotation Range
Cycle Life
Mechanical
Connections
Enclosure
Ambient Conditions
(Non-Condensing)
Audible Noise Rating
Dimensions
Weight
Agency
Certifications
Warranty
Disclaimer - The performance specifications are nominal and conform to acceptable industry standards.
For application at conditions beyond these specifications consult the local Bray office.
Bray, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
DC-310 Series
IOM Manual
DC24-310-T(A)
Non-Spring Return - Floating
with optional Auxiliary Switches (A)
Running: 2.6VA, 1.8W Holding: 0.8VA/0.5W
N/A
N/A
N/A
Standard Cable - 24 to 250 Vac; AC 6A resistive; AC 2A general purpose
Switch A - 0 to 90° with 5° Intervals (Recommended Range Usage 0 to 45°) Factory Setting 5°
Switch B - 0 to 90° with 5° Intervals (Recommended Range Usage 45 to 90°) Factory Setting 85°
Operating voltage: Class 2, in accordance with UL/CSA
Plenum type actuators as whole device: Class 2, in accordance with UL/CSA
Nominal Angle of Rotation 90°, mechanically limited to 95° ± 2°
Round Shafts - 3/8 to 1 in. (9.5 to 25.4 mm) diameter
Square Shafts - 1/4 to 5/8 in. (6 to 18 mm)
NEMA 1 in vertical position to 90 to the left and right of vertical. NEMA 3R rated with weather shield in the
vertical position. IP54 according to EN 60 529
Operating — -25 to 130°F (-32 to 55°C); 0 to 95% RH, non-condensing
Storage — -40 to 158°F (-40 to 70°C); 0 to 95% RH, non-condensing
(L) 11.8 x (W) 3.9 x (H) 2.9 in. (300 x 100 x 67.5 mm)
4.8 lb (2.2 kg) without switches; 5.2 lb(2.35 kg) with switches
CE conformity: Electromagnetic compatibility 2014/30/EU Low-voltage directive 2006/95/EC
Features
• Unique self-centering shaft coupling
• All metal housing
• Manual override
• Independently adjustable dual auxiliary switches available
• Built in potentiometer option
• Two torque ranges available
• UL, CE and cUL listed
with optional Auxiliary Switches (A)
310 lb-in. (35 Nm)
24 VAC/DC +-20%
Running: 2.7VA, 1.9W Holding: 0.9VA/0.6W
Timeout/Overload Protection
Yes
3 ft. (0.9 m) Pre-cabled - AWG 18
External Push Button
150 sec. at 50 Hz (125 sec. at 60Hz)
60,000 Full Strokes/5M Repositions
Minimum Shaft Length - 3/4 (20 mm)
<45 dBA at 1 m
UL listed to UL 60730
CSA E60730
5 Years limited from time of shipment.
1
Bray Commercial Division
13788 West Road, Suite 200A
Houston, Texas 77041
BCDSales@Bray.com
Phone: 1-888-412-2729
www.braycommercialdivision.com
© 2022 Bray International, Inc.
DCM24-310-T(A)
Non-Spring Return - Modulating
0(2)-10V
>100Kohms
DC 0 to 10 VDC
09/04/24

Advertisement

loading
Need help?

Need help?

Do you have a question about the DC-310 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bray DC-310 Series

  • Page 1 Disclaimer - The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications consult the local Bray office. Bray, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
  • Page 2 DC-310 Installation, Operation & Maintenance Manual Continued Actuator Parts a. Actuator b. Self-centering shaft adapter b’. Oversized shaft adapter c. Position indicator d. Shaft adapter locking clip e. Position indicator adapter f. Mounting bracket g. Mounting screws FIGURE 1 - Actuator Parts Safety Instructions - Definition of Terms Read, Follow and Save these instructions WARNING Personal injury or loss of life may occur if you do not follow the procedures as specified.
  • Page 3 DC-310 Installation, Operation & Maintenance Manual Continued 3. See Figure 3 and Figure 4 for clockwise-to- open (CW) installation. See Figure 5 and Figure 6 for counterclockwise-to-open (CCW) installation. For Tandem Applications: • The direction of rotation switches must be set identically on both actuators according to the clockwise or counterclockwise rotation of the shaft.
  • Page 4 DC-310 Installation, Operation & Maintenance Manual Continued Mechanical Range Adjustment The angular rotation is adjustable between 0° and 90° at 5- degree intervals. 1. Loosen the shaft adapter from the damper shaft and remove the actuator from the damper shaft. 2.
  • Page 5 DC-310 Installation, Operation & Maintenance Manual Continued Counterclockwise-to-open: Wiring • All wiring must conform to NEC and local codes and a. Insert the shaft adapter to the left as close as possible regulations. to the raised stop. • Use earth ground isolating step-down Class 2 transformers. b.
  • Page 6 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the nearest Bray office. Bray controls shall not be liable for damages resulting from misapplication or misuse of its products. The performance specifications are nominal and conform to acceptable industry standard...
  • Page 7 Retrofit Wiring Modulating Control Siemens Belimo Honeywell Johnson Bray 0(2)-10V (0 to 10 Vdc) GBB Series AMB Series MN7220 Series M9124 Series DC-310 Series GIB Series GMB Series MN7220 Series M9132 Series Function Color Number Color Number Terminal Number Terminal...

This manual is also suitable for:

Dc24-310-tDcm24-310-tDc24-310-taDcm24-310-ta