HWg-Juno family
Installation manual
Manual version 2.0 - HWg-Juno firmware 1.0.8
LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de

Advertisement

loading
Need help?

Need help?

Do you have a question about the HWg-Juno Series and is the answer not in the manual?

Questions and answers

Summary of Contents for HW Group HWg-Juno Series

  • Page 1 HWg-Juno family Installation manual Manual version 2.0 - HWg-Juno firmware 1.0.8 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 2 HWg-Juno family: Installation manual General HWg-Juno is HWg-Juno is I/O device for IP CCTV integration. You can simply connect Digital Inputs & Relay outputs to your current central IP video management system. HWg-Juno allows system integrator to design system with unlimited number of dry inputs and relay outputs. HWg-Juno solves location, quantity and quality limitation of I/O ports available on video encoder or IP camera.
  • Page 3 HWg-Juno family: Installation manual Quick navigation p. 8 Recommended HWg-Juno installation path Hardware installation Connect Decide Connect UTP patch cable Use provided PoE 5V DC external on Power supply between HWg-Juno and splitter power supply used PoE splitter Connect UTP cable Connect UTP cable Connect power patch from switch to...
  • Page 4 IP configuration of each unit. UDP config UDP Config utility – Is utility for discovery and IP configuration of all HW group hardware units. UDP config is available as installation package in root directory of the supplied CD (Windows and Linux versions).
  • Page 5 HWg-Juno family: Installation manual Restoring software factory defaults UDP config could be used for restoring default settings:  Reboot your unit  Click “Find devices” in UDP config utility  Open detail setting by double clicking on units entry.  Click the button “Load defaults”. This option is enabled only 30 seconds after unit reboot. ...
  • Page 6 HWg-Juno family: Installation manual HWg-Juno configuration HWg-Juno - Home HWg-Juno Home page displays unit status and show real-time status of inputs and outputs. Home page is automatically updated so port status is live. Home page displays currently active and disabled ports. Sensor section is reserved for future use.
  • Page 7 HWg-Juno family: Installation manual General setup Device name is transferred to your IP security application and is used for device identification. HWg-Juno admin page footnote. Note is displayed on all pages DNS is necessary only if NTP server is configured in HWg-Juno >...
  • Page 8 HWg-Juno family: Installation manual I/O configuration HWg-Juno inputs and outputs tab supports port configuration. www.HW-group.com 8 / 16 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 9 HWg-Juno family: Installation manual HWg-Juno Input ports supports 3 port input port modes  Remote – API  Simulation  Physical contact. Default input mode is Physical contact mode - PCM. HWg-Juno outputs support two port modes:  Remote  Simulation. Default output mode is Remote with OSM –...
  • Page 10 HWg-Juno family: Installation manual Disabling HWg-Juno ports HWg-Juno supports disabling unused input and outputs ports. This feature is useful for application with license model based on connected ports (like cameras, inputs, outputs). Genetec Omnicast and Genetec Security Center is example of application with such license policy. To save cost of SW licenses you could disable unused ports in HWg-Juno >...
  • Page 11 HWg-Juno family: Installation manual Input ports configuration Physical input mode – PCM mode has to be enabled on port by port basis in I/O tab of HWg-Juno admin interface. PCM is inputs specific feature. PCM mode is default. To configure Physical mode for selected port: ...
  • Page 12 HWg-Juno family: Installation manual Output ports configuration for Remote and Simulation mode Relay outputs could be configured to two modes:  Remote – control of relay output ports is done using from software using Genetec or PSIA protocol. Remote mode is Defaults settings ...
  • Page 13 HWg-Juno family: Installation manual Time Time configuration is optional for future use. Genetec protocol did not use internal unit clock. Time configuration using NTP server. Enter domain name only if you configured DNS server address in HWg-Juno > Home Manual configuration of the time and date www.HW-group.com 13 / 16...
  • Page 14 HWg-Juno family: Installation manual System Download unit’s configuration backup file. Upload unit’s configuration backup or unit’s firmware file. LED identification LED is illuminated after pressing the button. identification. Restore factory defaults Unit reboot www.HW-group.com 14 / 16 LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de...
  • Page 15 HWg-Juno family: Installation manual Appendix A: RIM API The remote control input – RIM has simple WEB based API. To control the HWg-Juno input port you have to set port into remote mode. State of the input is controlled by sending HTTP command to device: Single port control: To set port to CLOSED send request to the unit: http://device IP address/api/param.cgi?InputPin.1.State=close...
  • Page 16 HWg-Juno family: Installation manual RIM Security Remote input mode support unit security features. HWg-Juno unit supports Basic authentication. Access to unit is protected with user name and password. To configure protected access for RIM  Enter user name and password in units admin interface HWg-Juno > General setup ...