CONTENTS
1. SAFETY REGULATIONS AND INFORMATION
1.1 Hazard levels for warnings
1.2 Staff qualifications
1.3 Basic safety rules
1.4 Voltage
1.5 Safety and protective features
1.6 Electromagnetic radiation
1.7 Mechanical movement
1.8 Emissions
1.9 Hot surface
1.10 Transport
1.11 Storage
2. INTENDED USE
3. TECHNICAL DATA
3.1 Product drawing
3.2 Nominal data
3.3 Technical description
3.4 Mounting data
3.5 Transport and storage conditions
4. CONNECTION AND STARTUP
4.1 Mechanical connection
4.2 Electrical connection
4.3 Plug connection
4.4 Connection diagram
4.5 Checking connections
4.6 Switching on the device
4.7 Switching off the device
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
5.1 Cleaning
5.2 Safety inspection
5.3 Disposal
Item no. 13145-5-9970 · ENU · Change 256765 · Approved 2022-08-08 · Page 1 / 11
Operating instructions
1. SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1
1.1 Hazard levels for warnings
1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
2
2
2
2
2
2
2
2
3
4
4
5
5
5
5
6
1.2 Staff qualifications
6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
8
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9
9
1.3 Basic safety rules
9
The motor may only be operated with an impeller. The result is a motor-
fan combination. Motor and impeller assignment may only be done by
9
ebm-papst.
10
Protection against such things as:
10
electric shock
Contact with rotating parts
Ingress of foreign bodies or moisture
Excessive condensation
The safety hazards associated with the device must be assessed again
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.

Advertisement

loading
Need help?

Need help?

Do you have a question about the W2S135-EA79-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst W2S135-EA79-01

  • Page 1 Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. Item no. 13145-5-9970 · ENU · Change 256765 · Approved 2022-08-08 · Page 1 / 11...
  • Page 2 NOTE CAUTION Risk of fire The motor restarts automatically when operating voltage The risk of fire or flame propagation by ebm-papst products is applied, e.g. after a power failure. must be assessed by the commissioning party following Risk of injury installation in the final product.
  • Page 3 Operating instructions W2S135-EA79-01 2. INTENDED USE Intended use also includes Conveying air at an ambient air pressure between 800 mbar and ● 1050 mbar. Using the device within the permitted ambient temperature range; see ● Chapter 3.5 Transport and storage conditions and Chapter 3.2 Nominal data.
  • Page 4 Operating instructions W2S135-EA79-01 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Airflow direction "V" 6-pole connector housing consisting of TE 923 22.362.31, TE 40.A079.00, TE 40.A080.00 View without cap L1 (blue) N (brown) PE (green/yellow) not used not used not used Tightening torque 6.5±1.0 Nm...
  • Page 5 Operating instructions W2S135-EA79-01 3.2 Nominal data Approval EAC; UL 1004-1; CSA C22.2 No. 100 ; Use the device in accordance with its degree of protection. Motor M2S052-CA Information on surface quality Phase The surfaces of the products conform to the generally applicable industrial Nominal voltage / VAC standard.
  • Page 6 Operating instructions W2S135-EA79-01 4. CONNECTION AND STARTUP CAUTION Voltage The device is a built-in component and has no disconnecting 4.1 Mechanical connection switch. CAUTION → Only connect the device to circuits that can be switched off Cutting and crushing hazard when removing device with an all-pole disconnection switch.
  • Page 7 Operating instructions W2S135-EA79-01 4.3.2 Motor protection WARNING Device has no overheating protection The device is supplied without any automatic overheating protection. The device can become hot and catch fire. → For the version without thermal overload protector, also install a suitable motor protection switch.
  • Page 8 Operating instructions W2S135-EA79-01 4.4 Connection diagram blue green/yellow brown Item no. 13145-5-9970 · ENU · Change 256765 · Approved 2022-08-08 · Page 8 / 11...
  • Page 9 Deficient cooling Improve cooling ; When disconnecting, be sure to disconnect the ground connection last. In the event of further malfunctions, contact ebm-papst. 5.1 Cleaning To ensure a long service life, check the fans regularly for proper operation and soiling. The frequency of checking is to be adapted accordingly depending on the degree of soiling.
  • Page 10 Only ferrite magnets and not rare earth magnets are used in external Insulation of Visual inspection At least every Replace cables rotor motors from ebm-papst Mulfingen GmbH & Co. KG. cables for 6 months damage Item no. 13145-5-9970 · ENU · Change 256765 · Approved 2022-08-08 · Page 10 / 11...
  • Page 11 Electrolytic capacitors ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 13145-5-9970 · ENU · Change 256765 · Approved 2022-08-08 · Page 11 / 11...