W2S135-EB11-01
ASIA PACIFIC SHENGRUI LIMITED
Phone +00852 56261528
info@apacfan.com
www.apacfan.com
CONTENTS
Item no. 16918-5-9970 · ENU · Change 256765 · Approved 2022-08-11 · Page 1 / 11
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
2
2
2
2
2
2
2
3
4
4
5
5
5
5
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
7
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
9
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
WARNING
To reduce the risk of fire, electric shock or injury to people, do
not use any replacement or add-on parts that have not been
approved by ebm-papst (e.g. parts manufactured with a 3D
printer).

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W2S135-EB11-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst W2S135-EB11-01

  • Page 1: Table Of Contents

    To reduce the risk of fire, electric shock or injury to people, do not use any replacement or add-on parts that have not been approved by ebm-papst (e.g. parts manufactured with a 3D printer). Item no. 16918-5-9970 · ENU · Change 256765 · Approved 2022-08-11 · Page 1 / 11...
  • Page 2: Voltage

    Operating instructions W2S135-EB11-01 1.4 Voltage → Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts. ; Check the device's electrical equipment at regular intervals; see → Protect long hair with a cap. Chapter 5.2 Safety inspection.
  • Page 3: Intended Use

    Operating instructions W2S135-EB11-01 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions W2S135-EB11-01 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Direction of air flow "A" 6-pole connector housing consisting of TE 923 22.362.31, TE 40.A079.00, TE 40.A080.00 View without cap L1 (blue) N (brown) PE (green/yellow) not used...
  • Page 5: Nominal Data

    Operating instructions W2S135-EB11-01 3.2 Nominal data Approval EAC; UL 1004-1; CSA C22.2 No. 100 ; Use the device in accordance with its degree of protection. Motor M2S052-CA Information on surface quality Phase The surfaces of the products conform to the generally applicable industrial Nominal voltage / VAC standard.
  • Page 6: Connection And Startup

    Operating instructions W2S135-EB11-01 4. CONNECTION AND STARTUP NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can damage the 4.1 Mechanical connection device. CAUTION → Make sure the end of the cable is connected in a dry Cutting and crushing hazard when removing device environment.
  • Page 7: Plug Connection

    Operating instructions W2S135-EB11-01 4.3 Plug connection 4.3.1 Making supply connections ; Check your connector's pin assignment. ; Connect the built-in connector with the mating connector. ; Ensure that the connector is properly engaged. 4.3.2 Motor protection WARNING Device has no overheating protection The device is supplied without any automatic overheating protection.
  • Page 8: Connection Diagram

    Operating instructions W2S135-EB11-01 4.4 Connection diagram blue green/yellow brown Item no. 16918-5-9970 · ENU · Change 256765 · Approved 2022-08-11 · Page 8 / 11...
  • Page 9: Checking Connections

    Deficient cooling Improve cooling In the event of further malfunctions, contact ebm-papst. 5.1 Cleaning To ensure a long service life, check the fans regularly for proper operation and soiling. The frequency of checking is to be adapted accordingly depending on the degree of soiling.