7 Specifications

7.1 PERCEPTION 100 and PERCEPTION 200
Type:
Polar pattern:
Open-circuit sensitivity:
Frequency range:
Impedance:
Recommended load impedance:
Equivalent noise level
to CCIR 468-2:
Equivalent noise level
to IEC 60268-4 (A-weighted):
Signal/noise ratio
re 1 Pa (A-weighted):
Max. SPL for 0.5% THD:
Environment:
10
1-inch large-diaphragm, true con-
denser pressure-gradient micro-
phone
cardioid
18 mV/Pa (-35 dBV)
20 Hz to 20 kHz
(see frequency response graph)
≤200 ohms
≥1000 ohms
26 dB
16 dB-A
78 dB
135 / 145 dB SPL (0 / -10 dB)
temperature: -10°C to +60°C
R.H.: 80% (+25°C)
Powering:
Current consumption:
Connector:
Dimensions:
Net weight:
7.2 PERCEPTION 200 only
Bass cut filter slope:
Preattenuation pad:
FCC Statement
The device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, includ-
ing interference that may cause undesired operation.
48 V ±4 V phantom power
to DIN 45 596 / 268-15IEC
≤2 mA
3-pin XLR (pin 2 hot)
53 dia. x 160 mm high / 2 x 6.3 in.
525 g / 1.2 lbs.
12 dB/octave, 300 Hz
-10 dB (switchable)