Download Print this page
Lorentz PSk2 Series Manual
Lorentz PSk2 Series Manual

Lorentz PSk2 Series Manual

Pump controller replacing the interface board
Hide thumbs Also See for PSk2 Series:

Advertisement

Quick Links

Version: V150818
Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump
controller
Guide for replacing the Interface board in a PSk2 series pump
controller
Defective part:
Interface board v7 - v8 (7k-15k, 21k-40k)
Replacement part:
Interface board v8
BERNT LORENTZ GmbH & Co. KG
Siebenstücken 24, 24558 Henstedt-Ulzburg, Germany,
Tel (+49) 0 4193 8806-700, Fax -708, www.lorentz.de
Page 1 / 8
All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.

Advertisement

loading
Need help?

Need help?

Do you have a question about the PSk2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Lorentz PSk2 Series

  • Page 1 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller Guide for replacing the Interface board in a PSk2 series pump controller Defective part: Interface board v7 - v8 (7k-15k, 21k-40k) Replacement part: Interface board v8 BERNT LORENTZ GmbH &...
  • Page 2 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller Content Required tools ............................2 Equipment delivered..........................2 Safety instruction ............................. 3 Replacing the Interface board ........................4 4.1. Remove the touch protection ......................4 4.2.
  • Page 3 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller 3. Safety instruction READ AND FOLLOW ALL INSTRUCTIONS! RETAIN THESE INSTRUCTIONS FOR FUTURE USE!  Personnel qualification and the environment because of the manual and must be strictly training –...
  • Page 4 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller 4. Replacing the Interface board Always make sure to protect the electronic components from damage caused by electrostatic discharge (ESD)! We recommend wearing an ESD protection wristband during handling of electronic components.
  • Page 5 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller 4.2. Disconnect the connection to the Interface board a) Localize the Interface board. b) Unplug the ribbon cable connector. BERNT LORENTZ GmbH & Co. KG Siebenstücken 24, 24558 Henstedt-Ulzburg, Germany,...
  • Page 6 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller 4.3. Remove the Interface board a) Use the PH1 screwdriver to remove the four (4) metal screws of the Interface board. b) Now the board is only fixed by the red marked pin array.
  • Page 7 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller 4.4. Assemble the new Interface board a) Before reassembling the Interface board, make sure that the connector pins are well positioned. b) Push the new Interface board down carefully (the two fixation pins have to direct through the feed holes).
  • Page 8 Version: V150818 Guide for replacing the Interface board (v7 and v8) in a PSk2 series pump controller 4.5. Re-assemble the touch protection a) Reassemble the touch protection. b) Reassemble the three (3) fixation nuts with the 8 mm wrench. BERNT LORENTZ GmbH & Co. KG Siebenstücken 24, 24558 Henstedt-Ulzburg, Germany,...

This manual is also suitable for:

Ps15k2