WatchGas NEO Quick Start Manual

High-end photo-ionization detector
Hide thumbs Also See for NEO:

Advertisement

Quick Links

QUICKSTART
GUIDE
NEO
High-End Photo-Ionization
Detector
WatchGas | Klaverbaan 121 | 2908 KD Capelle aan den IJssel | The Netherlands | www.watchgas.com | info@watchgas.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the NEO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WatchGas NEO

  • Page 1 QUICKSTART GUIDE High-End Photo-Ionization Detector WatchGas | Klaverbaan 121 | 2908 KD Capelle aan den IJssel | The Netherlands | www.watchgas.com | info@watchgas.com...
  • Page 2 WARNINGS Read Before Operating The NEO BENZ’s User’s Guide must be carefully read by all individuals who have or will have the responsibility of using, maintaining or servicing this product. The product will perform as designed only if it is used, maintained and serviced in accordance with the manufacturer’s...
  • Page 3 • For optimal test results, it is recommended to allow the unit 2 minutes to warm up before taking measurements • Ensure that the water-trap filter is clean & replaced regularly. • Do not operate with a benzene filter tube in the holder for more than 15 min.
  • Page 4 USER INTERFACE The user interface has four-key operation, one big LCD with LED backlight, four red alarm LEDs, and one buzzer.
  • Page 5 5-second count down, until “Unit Off” is displayed. CHARGING Always fully charge the battery before use. Plug the charger to the bottom of NEO. The battery icon on the LCD shows the charge status. During active charging, the icon cycles from empty to full. CHARGING/COMM CABLE The USB Charging/Communications cable allows char- ging the unit on a personal computer.
  • Page 6 CHECKING THE ALARMS IMPORTANT! Test the alarms before performing a bump test or calibration. If any of the alarms are not re- sponding, check the alarm settings in Configuration Mode to make sure all alarms are enabled (Config Mode › Alm Setting ›...
  • Page 7 ENTERING AND EXITING CONFIG MODE Press and hold the Up and Down buttons simulta- neously for 3 seconds to enter Config Mode. Config Mode is password protected. • The default password is “0000”. • Enter all four digits, move the cursor to √ and press the Up button to enter Config Mode.
  • Page 8 • Mnt (Monitor) Setup: Date & Time, Display, Pump Speed, Pump Stall, 3-Point Cal., Rolling Graph, Real-Time Data Time Data), Language, Self-Zeroing • Wireless: Wireless data transmission on/off To ac- cess standard gas calibration: Config Mode > Cali- bration > Standard Gas Calibration (Span Calib) To start standard gas calibration: Apply Gas >...
  • Page 9 ZERO POINT CALIBRATION Zero Calibration sets the baseline for the sensor and is performed in normal fresh air or another clean air source. • To enter fresh air calibration: • Config Mode > Calibration > Zero Calib. To start fresh air calibration: Pressing the Right button starts a countdown timer.
  • Page 10 Replace the dust/water block filter regularly, especially when used in dusty environments. For information on re- placing batteries, lamps, or sensors, or other maintenan- ce, refer to the User Manual or contact WatchGas. WatchGas B.V. Klaverbaan 121 2908 KD Capelle aan den IJssel...