Sander CERTIZON C25 Instruction Manual

Ozonisator

Advertisement

Instruction Manual
Ozonisator
CERTIZON
C25 C50 C100 C200 C300
Erwin Sander Elektroapparatebau GmbH
Am Osterberg 22
DE 31311 Uetze-Eltze
Tel +49 5173 971 0
Fax +49 5173 971-197
www.aqua-sander.de
Version 07/2024
info@aqua-sander.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CERTIZON C25 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sander CERTIZON C25

  • Page 1 Instruction Manual Ozonisator CERTIZON C25 C50 C100 C200 C300 Erwin Sander Elektroapparatebau GmbH Am Osterberg 22 DE 31311 Uetze-Eltze Tel +49 5173 971 0 Fax +49 5173 971-197 www.aqua-sander.de Version 07/2024 info@aqua-sander.de...
  • Page 2 The device is not intended for commercial use. Erwin Sander shall not be held liable for any damages that occur as a result of any unauthorized mod- ifications, reengineerings or amendments made to the ozonizer or its improper use.
  • Page 3: Device Setup

    Device Setup 1 Potentiometer 3 Air connection 5 Connection plate 7 LED for Ozone element 2 Power connection 4 Ozone connection 6 Screws The air and ozone connections are designed for 4i/6a mm tubes. Technical Data Ozone output: 25 mg/h, 50 mg/h, 100 mg/h, 200 mg/h, 300 mg/h Power supply: 100 to 240 VAC 50/60Hz Operating voltage:...
  • Page 4: Safety Information

    Usage of the ozone generator with any other power supply UNIT constitutes a material alteration of the product and Erwin sander shall not be held liable for any damages that occur as a result of such an alteration.
  • Page 5: Warranty And Limitations Of Liability

    Except as provided in this warranty and to the maximum extent permitted by law, Erwin Sander is not responsible for direct, special, incidental or con- sequential damages under any legal theory.
  • Page 6 Installing/Positioning the Ozonizer Proposal A: Wall mounting On the rear of the ozonizer is a suspension hole for mounting the ozonizer on a wall. If possible, the device should be installed at a level higher than the surface of the water (e.g. to prevent water from flowing back into the device in the event of a power outage).
  • Page 7: Start-Up Procedure

    LED (7) lights up and gets brighter as the output increases. At 100% output, the LED is permanently lit up. To determine the ozone requirements, we recommend measuring the redox potential with a Sander redox measuring and regulating device, which switches the ozonizer on and off automatically depend- ing on the set target value.
  • Page 8 Faults The ozone output can be reduced or interrupted through the ingress of water or dirt particles. Such impairments can be rectified by cleaning the device (see “Cleaning procedure”). If such impairments cannot be rectified by cleaning the device, please contact your specialist dealer or send the device directly to the manufacturer.