GAS RANGES GENERAL INFORMATION Before installing the appliance, read operation and maintenance instructions carefully.Wrong installation and part changing may damage the product or may cause injury on people.These are not in our company’s responsibility to damage the ...
*The Professional plus Gas Ranges,that provides high efficiency has been designed to be used in industrial kitchens. Dimensions Weight Packaging Product Code Model (mm) (kg) Dimensions (mm) EMP.6KG010 2 Burner Ranges 400x650x290 480x760x600 EMP.6KG020 4 Burner Ranges 600x650x290 700x760x600 EMP.6KG010-O 1 Burner Ranges...
GAS RANGES INSTALLATION *Please place the product to straight and sturdy ground,please take necessary steps against possibility of overturn. *Technician who will serve for installation and service for the appliance must be professional on this subject and must have installation and service licenses by the company.
GAS RANGES SAFETY INSTRUCTIONS *Do not use the appliance in insufficient lighted place. *Do not touch the moving attachments while the appliance operates. *Do not install the appliance in the presence of flammable or explosive materials. ...
GAS RANGES OPERATION *Control Panel; A : OFF Position B : Lighter Position C : Full Flame D : Half Flame *Operating; According to type of use,make gas entrance connection from behınd the appliance.Because the machine is operated with LPG and NG.
GAS RANGES CLEANING & MAINTENANCE CLEANING AND MAINTENANCE AFTER EVERY USE Turn off the gas connection before cleaning. Clean the outer surface of the appliance with a wet cloth and chrome shiner. ...
GAS RANGES TROUBLESHOOTING Check if the gas connection is done or not. If there is no gas entrance to pilot,the THE APPLIANCE DOESN’T OPERATE appliance is not operated. If the hoses that have gas entrance lose gas due to slit,hole.etc.,the appliance is not operated.
GAS RANGE BURNER-INJECTOR CHANGE CHART NG / LPG 30/50 mbar 30/50 mbar mm Ø 1,40 Ø 1,40 Ø 0,97 Ø 0,97 EMP.6KG010 mm Ø 1,40 Ø 1,40 Ø 0,97 Ø 0,97 EMP.6KG020 mm Ø 2,20 Ø...
Page 11
GAS RANGES Change of Burner Injector; Take off the grill and upper lid of burner (Image 1) Change B injector by paying attention to the datas at chart with suitable injector. Adjust the burner entrance setting by loosening ‘C’ bolt (Image 2) Change B injector by paying attention to the datas at chart with suitable injector.For this it is enough to take off ‘D’...
Page 17
GAS RANGES SPARE PART LIST-EXPLODING DRAWING PRODUCT CODE: EMP.6KG020 PRODUCT NAME P.CODE 53*28 CM CASTING FURNACE M.AKS-DKM-KZN-001 INJECTOR M6*0.75 Ø1.40 MM M.GAZ-ENJ-LPG-002 BURNER WITH LPG M.GAZ-BRL-BEK-003 UNION BODY M.GAZ-TES-SRI-022 IGNITION PLUG M.GAZ-CKM-BUJI-004 M8*1000 NO:20 THERMO ELEMENT M.GAZ-TRL-004 GAS TANK M.GAZ-DPO-SNC-007...
Page 35
GAS RANGES SPARE PART LIST-EXPLODING DRAWING PRODUCT CODE: EMP.PLS.9KG020-O PRODUCT NAME P.CODE M.AKS-KLP-BKL-020 NO:3 HANDLE TOP COVER M.PLTN-MUH-SYH-044 PLATINUM ARA-KNX.PG9-0008 40 CM X 7 CM CHIMNEY JP.M.AKS-DKM-KZN-013 PILOT GROUP TEAM M.GAZ-PLT-PLT-001 M8*1200 THERMOELEMENT NO:18 M.GAZ-TRL-003 BURNER LNG M.GAZ-BRL-BEK-006...