Download Print this page

Advertisement

Quick Links

Job Title:
Job Site:
Elevation: (ft)
Date:
Submitted By: Tim Barham
P.O. Box 410
CAPS 4.16.1923
Eisenhower MS & HS
EISENHOWER MIDDLE & HS
4333 S SUNNYSLOPE RD
NEW BERLIN , WI 53151
United States
692
03/10/15
VYRON CORPORATION
401 PILOT CT STE A
WAUKESHA , WI 53188-2481
US
Phone: (262)783-3600
Fax:
Email Address: tbarham
Schofield, WI 54476
G:\Sales Office\2014\32936\Eisenhower MS & HS.gfcj
(262)544-6400
@vyron.com
(715) 359-6171
FAX (715) 355-2399
www.greenheck.com
Page 1 of 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the ES Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Greenheck ES Series

  • Page 1 401 PILOT CT STE A WAUKESHA , WI 53188-2481 Phone: (262)783-3600 Fax: (262)544-6400 @vyron.com Email Address: tbarham P.O. Box 410 Schofield, WI 54476 (715) 359-6171 FAX (715) 355-2399 www.greenheck.com CAPS 4.16.1923 G:\Sales Office\2014\32936\Eisenhower MS & HS.gfcj Page 1 of 2...
  • Page 2 Eisenhower MS & HS Product IOMs Mark Name Model Name ERU GBDD, GBDD EM-30 ERU MOD VCD-23 EF-6, EF-7 CUBE EF-4, EF-5 EF-3 EF- 2, EF-1 CAPS 4.16.1923 G:\Sales Office\2014\32936\Eisenhower MS & HS.gfcj Page 2 of 2...
  • Page 44: Constant Pressure Control

    PN 474766 Vari-Green Control Constant Pressure Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
  • Page 45 Forming a drip loop in the tubing just before it enters stored indoors in a clean, dry atmosphere. the Greenheck Constant Pressure Controller is good practice. (The distance from the bottom of the loop Remove any accumulations of dirt, water, ice, or to the controller’s pressure port should be one to two...
  • Page 46 Positioning the duct pressure tap to get the best results depends on the layout of the system. For way from the bottom of the duct. is representative of the zone near the center of the Select a location on the duct that is a minimum space that is in the zone being monitored.
  • Page 47 Wall Mount open to atmosphere. One Duct Static Tap and One Duct Total Tap – Mounting Plate This allows the system to automatically adjust the loading. Connect the “H” tubing connector on the Cover Constant Pressure Control to the total pressure the static pressure tap using 1/4”...
  • Page 48 The Constant Pressure Control has three buttons circuit board inside the lid is jumper J5. J5 is used to set the controller into normal operation, RUN, or programming mode, PROG. Position Programming allows the user to customize the operation on the Constant Pressure Control. The If power to the controller is lost, all settings will be retained.
  • Page 49 Auto zero sets the zero pressure reading of the be adjusted as well. It is recommended that you controller. Greenheck recommends performing auto make sure your pressure set point is correct before continuing.
  • Page 50 One of two things must happen for the system to override switch is opened. The override can be Closing the contact will activate the override. fan, etc. is turned on and will vary the exhaust fan speed appropriately. when the override switch is closed. manually awakened from cutout mode, hold the Enter button for 5 seconds and the system will return to normal operating mode.
  • Page 51 If the controller shuts the fan off when there is demand on the system, the cutout Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will the motor manufacturer for a period of one year.