Summary of Contents for MedPro Defense nocospray

  • Page 1 Owner’s Manual www.nocospray.ca...
  • Page 2: Table Of Contents

    Table of contents What is the Nocospray system? ® How to use Cleaning and maintenance Do’s and Don’ts Troubleshooting Technical information Notes Warranty Important • Specific uses and circumstances can vary the number and sequence of steps involved in using the system • Always follow your institution’s cleaning protocols prior to disinfecting with the Nocospray System ®...
  • Page 3: What Is The Nocospray ® System

    What is it? The Nocospray System is the combination of a ® portable, patented, propulsion machine and the hydrogen peroxide-based disinfectant created to act synergistically with it When used as directed the system can disinfect all hard surfaces in an enclosed area The dose applied is determined by the volume of the room to treat Nocolyse disinfecting solution Nocospray...
  • Page 4: How To Use

    How to use 1. Remove soft surfaces and disposable items from the room (ex. bed sheets, open food containers). Clean the room as per your institution’s current protocol for manual cleaning 3. Close windows and excessive ventilation (ex. negative pressure) systems. Make sure that all hard surfaces are accessible to the Nocolyse gas. For example, open any doors in the room (ex. bathroom door, drawer). Lean the mattress on its edge so that as much of the surface as possible can be disinfected Place the Nocospray on a table or cart...
  • Page 5: Cleaning And Maintenance

    7. Attach the bottle of Nocolyse. • Ensure that there is enough liquid to treat the room • Make sure you hear the ‘Click’ Plug in the machine and turn on the power at the back (light should be green). 9. Set the touchpad to the correct volume (m The chosen volume will be illuminated. If two lights are illuminated, the chosen volume is in the mid-point between the two. 10. Make sure you can leave the room easily. No one should be in the room during the Nocospray disinfection 11 Press the button on the side of the machine –...
  • Page 6: Dos And Don'ts

    Dos and Don’ts Do Get the most out of your Nocospray System by reviewing the booklet and the online training tools periodically This will help ensure proper consistent use of the system and that you achieve the best possible results. You can find the online tools at www.nocospray.ca/en/buyer-tools You will need to request a username and password through the site to gain access Do Discuss where you are using your system with the AMG Team They are in the best...
  • Page 7 Don’t Use any liquid other than Nocolyse products with your Nocospray machine Doing so may damage the machine and compromise your results Any damage caused by using a liquid other than Nocolyse is not covered by any warranty or service contract. Don’t Open your machine The Nocospray machine is portable and easy to use But it is still made up of electronics and moving parts. Opening the machine can damage the internal mechanism...
  • Page 8: Troubleshooting

    Troubleshooting Emergency Stop The device can be stopped at any moment by pressing on the button at the rear to the off position (green light goes off) or unplugging the machine. If you are entering the room while the machine is running or before the end of the appropriate contact time, make sure that you are wearing personal protective equipment and that you spend the least amount of time possible in the room No one should be permanently installed in the room (patient or staff) until the entire contact time has elapsed Please refer to the instructions for use for more details Fig 1 Nozzle...
  • Page 9 Try this: The device does not start • Verify that the machine and the green light of the is plugged in securely switch On/Off is not lit. and that there is elec- tricity flowing to the outlet • Verify that the fuse on the back the device is not damaged (see fig. 1). The device works but • Verify that the nozzle Nocolyse consumption is in place and that it is is higher or lower than...
  • Page 10: Technical Information

    Technical information Nocospray Machine 1000 m Model: 007-020 Power: 1000 W Voltage: 115 V Reservoir capacity: 1 liter Weight (Full): 6.5 kg Weight (Empty): 5.8 kg Dimensions: 50 cm x 33 cm x 37 cm...
  • Page 11: Notes

    Warranty MedPro Defense Nocospray System 1 year limited ® warranty A M G Medical Inc warrants the Nocospray against defects in material or workmanship A M G Medical’s warranty does not cover product abuse or normal wear Use of the Nocospray with any other product than Nocolyse voids this warranty. Repairs, modifications or use of parts other than those supplied by A M G Medical without prior written authorization will void this warranty.