9. Handling Precautions ....................14 10. Warranty ......................14 11. Specifications ......................15 11.1 Specifications of the Converter (VM-5011A) ............15 11.2 Standard Characteristic of the Converter ............. 16 11.3 Outer Dimensions of the Converter ..............16 11.4 Specifications of the Accelerometer ..............17 12.
In addition to the danger level classification, this document also uses the following notation: Memo: "Memo" describes supplementary explanations that could not be explained in the text and information that is useful to know. Instruction Manuals of the Signal Converter VM-5011A...
Page 4
Please check in the actual environment whether the measurement data can be obtained as expected, and after confirming that there are no problems, start operation in earnest. Instruction Manuals of the Signal Converter VM-5011A...
2. Features (1) Simultaneous monitoring of E Acceleration and the velocity levels. (2) Several accelerometers are available for connecting to the converter. (3) The converter is compact and can be mounted on DIN rail. Instruction Manuals of the Signal Converter VM-5011A...
●Option (Not in included in price) Name Model Remarks Cable of the VP-1001005406 MS-AC010-5 Straight Connector Length: 5m MS-AC011-5 Right Angle Connector Magnet for mounting MH-205R for Flat Surface Accelerometer MH-206R for Curved Surface Instruction Manuals of the Signal Converter VM-5011A...
Especially, since the accelerometer measures up to high frequencies, make mounting surface flat and tap M6 female screw perpendicular to mounting surface (Fig.4-2). A φ0.02 A 8mm or more Fig.4-2 Processing of the accelerometer mounting surface Instruction Manuals of the Signal Converter VM-5011A...
Install the converter in a clean place with as little noise as possible and little vibration or temperature change. 5. Wiring Method Connect the power supply, the accelerometer and various subsequent instruments according to the wiring diagram shown from p8 to p10. Instruction Manuals of the Signal Converter VM-5011A...
Page 9
Instruction Manuals of the Signal Converter VM-5011A...
Page 10
Instruction Manuals of the Signal Converter VM-5011A...
Page 11
Instruction Manuals of the Signal Converter VM-5011A...
(2) Remove the converter from DIN rail. (3) Push lock hooks on the top and bottom of the converter with a flat-blade screwdriver. Release the lock, then hold upper housing and pull it out from base housing (see Fig.7-1). Instruction Manuals of the Signal Converter VM-5011A...
Page 13
✔ 0~100m/s E rms 10mm/s rms Velocity 25mm/s rms Measuring Range 50mm/s rms ✔ 100mm/s rms (*) Do not turn on more than one switch. Fig.7-2 Setting of Measurement Range and DC Output Instruction Manuals of the Signal Converter VM-5011A...
Refer to "Section 5" for how to connect the VP-8021A to the converter. Memo (1) Refer to “Section 7” for how to pull out the board. (2) For more information on the VP-8021A, please check our website. URL: https://we-are-imv.com/en/ Instruction Manuals of the Signal Converter VM-5011A...
This product is shipped after strict inspection in our factory. But in case the system has a fault caused by the responsibility of IMV as the defect under production and material during the warranty period, we will repair or replace it free of charge. However, consumables such as lamps will be excluded.
Outer Dimensions (Excluding protrusions) W22.6×H99×D113.6mm (See p16) Weight Approx. 150g *1 ”■” is factory default settings. *2 Refer to “11.2 Standard Characteristic of the Converter”. VP-1001000206 (VP-100), VP-1001000106 (VP-100R), and VP-1001005406 are applicable. Instruction Manuals of the Signal Converter VM-5011A...
Code No. Input Type Sensitivity Output1 Range Output2 Range [ mV / m/s ] [ m/s E [ mm/s Power 10.2 IEPE Sensor Voltage QC Pass : IEPE Sensor signal converter Unit [mm] Instruction Manuals of the Signal Converter VM-5011A...
Cable Sheath Material SUS Braided Cable Cable Length 5m (Standard Length) Outer Dimensions See below Figure φ22 SUS Braided Cable M6(P=1) Male Screw 1/4-28"UNF - M6 Screw Mounting Outer Dimensions of the VP-1001000206 (Unit: mm) Instruction Manuals of the Signal Converter VM-5011A...
Page 19
M6 Screw Cable Sheath Material Cable Length 5m (Standard Length) Outer Dimensions See below Figure φ22 PUR Cable M6(P=1) Male Screw 1/4-28"UNF - M6 Screw Mounting Outer Dimensions of the VP-1001000106 (Unit: mm) Instruction Manuals of the Signal Converter VM-5011A...
Page 20
Case Material SUS303 Mounting Method M6 Screw Cable Connecting Method M12 Connector Outer Dimensions See below Figure φ22 M6(P=1) Male Screw 1/4-28"UNF - M6 Screw Mounting Outer Dimensions of the VP-1001005406 (Unit: mm) Instruction Manuals of the Signal Converter VM-5011A...
Page 21
Finished Outer Diameter: Approx. 5.9mm Cable Length: Brown (No use) White Silver (Shield) Blue (No use) Black MS-AC010-5 Straight Connector Brown (No use) White Silver (Shield) Blue (No use) Black φ15 MS-AC011-5 Right Angle Connector Instruction Manuals of the Signal Converter VM-5011A...
Page 22
5m (Standard Length) Outer Dimensions See below Figure M6(P=1) Depth 5mm Outer Dimension of VP-8021A (Unit: mm) Memo For detailed specifications of the VP-8021A, please refer to the instruction manual for the VP-8021A. Instruction Manuals of the Signal Converter VM-5011A...
The converter is out of order. If you own a converter of the same specifications, check if the phenomenon is reproduced or if the phenomenon is switched by replacing the converter. Vibration is unstable or large (small). ― Instruction Manuals of the Signal Converter VM-5011A...
RMS-DC 4-20mA Value Waveform Conversion Output Conversion E Acc. Bandpass Range High Pass Low Pass DC Output Filter 0-10V Setting Filter Filter Output 500 to10kHz 10Hz 1kHz Fig.13-3 Block Diagram of E acceleration Instruction Manuals of the Signal Converter VM-5011A...
By grounding at two points, a loop is formed through the ground wire, which adversely affects the minute signal flowing through the accelerometer signal line, which may prevent correct vibration measurement. Instruction Manuals of the Signal Converter VM-5011A...
(1) Refer to "Section 7" for how to pull out the board. (2) In the case of voltage input connection, POWER lamp lights up after power is supplied regardless of the cable connection status to the accelerometer input terminal. Instruction Manuals of the Signal Converter VM-5011A...
Page 27
Accelerometer Ground Fig.A-3 Connection example of voltage input specification the converter Caution Before performing the wiring work, turn off the power supply to the converter. Instruction Manuals of the Signal Converter VM-5011A...
The adsorption force of magnet decreases due to deterioration over time. The Accelerometer may detect a large impact or vibration that occurs when it falls off the mounting surface due to a decrease in adsorption force. Instruction Manuals of the Signal Converter VM-5011A...
(63%) Faster response time of DC output enables more real-time vibration level output. The meaning of each phrase is as follows: ACC: Acceleration, E ACC: Envelope Acceleration, VEL: Velocity RMS: Root Mean Square Instruction Manuals of the Signal Converter VM-5011A...
Page 30
MES Business Division (Vibration Measuring Systems Sales Section) Address: 2-6-10 Takejima, Nishiyodogawa-ku, Osaka, 555-0011, Japan TEL: +81 50 1745 6779 FAX: +81 6 6471 3158 * Specifications and appearance described in this document are subject to change without notice. Instruction Manuals of the Signal Converter VM-5011A...
Need help?
Do you have a question about the VM-5011A and is the answer not in the manual?
Questions and answers