IMV VM-5011A Instruction Manuals

Signal converter

Advertisement

Quick Links

Instruction Manuals of Signal Converter
(Detailed Edition)
MODEL: VM-5011A
Manufacturer:
Document No.:
Created Date:
Version:
Total Page:
- 1 -
IMV CORPORATION
TVE-6-4188E
th
8
April, 2021
1.20
22
VM-5011A Instruction Manuals
(TVE-6-4188E / Version 1.20)

Advertisement

Table of Contents
loading

Summary of Contents for IMV VM-5011A

  • Page 1 Instruction Manuals of Signal Converter (Detailed Edition) MODEL: VM-5011A IMV CORPORATION Manufacturer: Document No.: TVE-6-4188E Created Date: April, 2021 Version: 1.20 Total Page: VM-5011A Instruction Manuals - 1 - (TVE-6-4188E / Version 1.20)
  • Page 2: Table Of Contents

    7. Change of Measurement Range and DC Output ............9 8. Handling precautions ................... 11 9. Warranty ......................11 10. Specifications ....................12 10-1. Specifications of Converter (VM-5011A) ............12 10-2. Standard Characteristic of Converter ..............13 10-3. Outer dimensions of Converter ..............13 10-4. Specifications of Piezoelectric Acceleration Sensor ..........14...
  • Page 3: Introduction

    In addition to the danger level classification, this document also uses the following notation: Memo: "Memo" describes supplementary explanations that could not be explained in the text and information that is useful to know. VM-5011A Instruction Manuals - 3 - (TVE-6-4188E / Version 1.20)
  • Page 4 Please check in the actual environment whether the measurement data can be obtained as expected, and after confirming that there are no problems, start operation at full scale. VM-5011A Instruction Manuals - 4 - (TVE-6-4188E / Version 1.20)
  • Page 5: Overview

    (E acceleration) Waveform Output (Velocity) Power Standard Components 24VDC 3-2. Equipment Configuration Name Model Remarks Signal Converter (Converter) VM-5011A Piezoelectric VP-100 Select VP-100 or VP-8021A Acceleration Sensor at the time of purchase VP-8021A (Sensor) Memo (1) Above-mentioned composition is one set.
  • Page 6: Installation Method

    Especially, since acceleration sensor measures up to high frequencies, make mounting surface flat and tap M6 female screw perpendicular to mounting surface (Fig. 4-2). A φ0.02 A 8mm or more Fig.4-2 Processing of sensor mounting surface VM-5011A Instruction Manuals - 6 - (TVE-6-4188E / Version 1.20)
  • Page 7: Laying Of Sensor Cable

    Install converter in a clean place with as little noise as possible and little vibration or temperature change. 5. Wiring Method Connect power supply, sensor and various subsequent instruments according to the wiring diagram shown on the next page. VM-5011A Instruction Manuals - 7 - (TVE-6-4188E / Version 1.20)
  • Page 8 VM-5011A Instruction Manuals - 8 - (TVE-6-4188E / Version 1.20)
  • Page 9: Power On Converter

    Hold upper housing and pull it out Base Housing Unlock lock hook When returning to original using a flat-blade position, align board with screwdriver, etc. guide (groove). Fig.7-1 Pulling out upper housing VM-5011A Instruction Manuals - 9 - (TVE-6-4188E / Version 1.20)
  • Page 10 (3) Please do not forget to record and manage the settings. (5) After completing the settings, insert upper housing into base housing, check that lock hook is locked, attach it to the DIN rail, and reconnection each cable. VM-5011A Instruction Manuals - 10 - (TVE-6-4188E / Version 1.20)
  • Page 11: Handling Precautions

    This product is shipped after the strict inspection in our factory. But in case the system has the fault caused by the responsibility of IMV as the defect under production and material during warranty period, we will repair or replace free of charge. However, consumables such as lamps will be excluded.
  • Page 12: Specifications

    10. Specifications 10-1. Specifications of Converter (VM-5011A) Model VM-5011A Input Range 0~500m/s Measuring Range of E acceleration 10Hz to 1kHz Frequency Band Pass Filter: 500Hz~10kHz See “10-2. Standard Characteristic of Converter” Velocity 10Hz to 1kHz (ISO 2954:2012 Filter Characteristics compliant) See “10-2.
  • Page 13: Standard Characteristic Of Converter

    Input Type Sensitivity Output1 Range Output2 Range [ mV / m/s ] [ m/s E [ mm/s Power 10.2 IEPE Sensor Voltage QC Pass : IEPE Sensor signal converter Unit [mm] VM-5011A Instruction Manuals - 13 - (TVE-6-4188E / Version 1.20)
  • Page 14: Specifications Of Piezoelectric Acceleration Sensor

    Cable Sheath Material SUS Braided Cable Cable Length 5m (Standard Length) Outer Dimensions See below Figure φ22 φ4 M6(P=1) Male Screw 1/4-28"UNF - M6 Screw Mounting Outer Dimensions of VP-100 (Unit: mm) VM-5011A Instruction Manuals - 14 - (TVE-6-4188E / Version 1.20)
  • Page 15 A5052 (Alumite treatment) Mounting Method M6 Screw Cable Sheath Material ETFE Cable Length 5m (Standard Length) Outer Dimensions See below Figure M6(P=1) Depth 5mm Outer Dimension of VP-8021A (Unit: mm) VM-5011A Instruction Manuals - 15 - (TVE-6-4188E / Version 1.20)
  • Page 16: Maintenance And Troubleshooting

    Converter is out of order. If you own converters with the same specifications, replace converters and check if the phenomenon is reproduced or replaced. Vibration is unstable or large (small). ― VM-5011A Instruction Manuals - 16 - (TVE-6-4188E / Version 1.20)
  • Page 17: About Envelope Acceleration (E Acceleration)

    Waveform Conversion Output Conversion E Acc. Bandpass Range High Pass Low Pass DC Output Filter Setting 0-10V Filter Filter 500 to10kHz Output 10Hz 1kHz Fig.12-3 Block Diagram of E acceleration VM-5011A Instruction Manuals - 17 - (TVE-6-4188E / Version 1.20)
  • Page 18: Appendix.1 How To Connect With Vp-8021A

    (1) Refer to "7. Change of Measurement Range and DC Output" for how to pull out the board. (2) For more information on VP-8021A, please check our website. URL: https://www.imv.co.jp VM-5011A Instruction Manuals - 18 - (TVE-6-4188E / Version 1.20)
  • Page 19: Appendix.2 When The Place Where Sensor Is Attached Is Not Grounded

    By grounding at two points, a loop is formed through the ground wire, which adversely affects the minute signal flowing through the sensor signal line, which may prevent correct vibration measurement. VM-5011A Instruction Manuals - 19 - (TVE-6-4188E / Version 1.20)
  • Page 20: Appendix.3 About Voltage Input Connection Specifications

    (1) Refer to "7. Change of Measurement Range and DC Output" for how to pull out the board. (2) In the case of voltage input connection, POWER lamp lights up after power is supplied regardless of the cable connection status to the sensor input terminal. VM-5011A Instruction Manuals - 20 - (TVE-6-4188E / Version 1.20)
  • Page 21 ◎Example of using voltage input connection Use sensor waveform output of another type of converter (VM-5011B etc.) and connect it to the sensor input terminal of voltage input specification converter (VM-5011A). This makes it possible to measure E acceleration (m/s E rms) and velocity (mm/s rms) at the same time (see Fig.A-4).
  • Page 22: Appendix.4 About Magnet (Sensor Mounting Options)

    In addition, sensor may be damaged due to the impact or vibration when it is dropped. So, it is recommended to use screws to fix sensor when it is always installed and monitored vibration. VM-5011A Instruction Manuals - 22 - (TVE-6-4188E / Version 1.20)