Download Print this page
AT&T Bell System Dataspeed 5A Troubleshooting Manual
AT&T Bell System Dataspeed 5A Troubleshooting Manual

AT&T Bell System Dataspeed 5A Troubleshooting Manual

Tape-to-tape system tape senders
Hide thumbs Also See for Bell System Dataspeed 5A:

Advertisement

Quick Links

(
BELL SYSTEM PRACTICES
AT&TCo Standard
SECTION 582-102-315
Issue 4, December 1974
"DATASPEED*"
TAPE-TO-TAPE SYSTEM
TAPE SENDERS 5A AND 5C
TROUBLESHOOTING
CONTENTS
1.
GENERAL
.....
2.
3.
TROUBLESHOOTING
GENERAL
.....
.
CABINET CIRCUIT -
5C SENDER
TAPE READER
TAPE SENDERS 5A AND
5C CIRCUITS
A.
General
B.
C.
.
D.
E.
F.
.
G.
H.
A.
B.
C.
On-Line Test
TROUBLESHOOTING
PROCEDURES
. . . .
TROUBLESHOOTING
TABLE
USAGE
...........
.
Index for Table B - Symptom
or Trouble Report
Table B - Troubleshooting
5A and 5C Senders
. . . .
Table C - 5A and 5C Tape
Sender Symbols, Abbreviations,
and References
. . . . . . . .
*Registered Trademark of AT&TCo
PAGE
1
1
2
2
2
2
3
3
3
3
6
7
7
7
7
7
8
9
11
11
12
13
14
22
1.
GENERAL
1.01
This section
provides troubleshooting
procedures
for , DAT ASPEED
Tape
Senders 5A and 5C.
It
is reissued
to
update the
text and add to the troubleshooting
table. The
following TCNs have been included in this issue,
928 and 1120. Since this is a general revision,
marginal
arrows
ordinarily
used
to . indic_ate
changes and additions
are omitted.
This sect10n
was formerly 592-807-300.
1.02
General description
and operation
in-
formation,
installation procedures, and
adjustment
and lubrication information are found
in related sections.
1.03
The description
of circuit operation in
this section
references
schematic
dia-
grams in another
section. The circuit elements
shown on these diagrams are referenced
in the
text and may be located according to the follow-
ing system:
3 A 2
T
1.___ Numerical coordinate on
L_sheet
Alphabetical coordinate on
sheet
'-------Wiring
diagram sheet num-
ber
'-----'---Schematic
wiring diagram
number
2.
EQUIPMENT REQUIRED
2.01
Troubleshooting
requires
the
usual
tools
(screwdrivers,
wrenches,
etc)
found in Section 570-005~800.
2.02
A
standard
volt-ohm-milliammeter,
some strapping wire, and test tapes are
also required.
Prepared for American Telephone and Telegraph Company by Teletype Corporation
©
1964, 1967 and 1974 by Teletype Corporation
All rights reserved
Printed in U.S.A.
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Bell System Dataspeed 5A and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Bell system dataspeed 5c