If you have difficulty with your Thermostat, try these suggestions.
Most problems can be corrected quickly and easily.
All models | |
Screen is blank | Replace the batteries (T3 & T3R only). Check the OpenTherm boiler has power (T3M only). Contact installer. |
Thermostat shows ![]() | Batteries have less than 10% power and need to be replaced soon. |
Thermostat shows ![]() | Batteries are critically low and need to be replaced immediately - see 'Changing the Batteries'. |
Thermostat shows ![]() | The boiler cycles on and off as it controls the temperature, and sometimes the ![]() If the boiler doesn't switch on after a long period of time contact your installer. |
Heating system does not respond to temperature adjustments. | Make sure the set temperature is higher than the actual room temperature. Check the heating system is powered on. Check the Receiver Box is powered and the Thermostat has a wireless signal (T3R only). |
Thermostat shows ![]() | The temperature sensor of your Thermostat is faulty, contact your installer to repair or replace the Thermostat. |
![]() | Boiler service reminder (UK Only). The boiler is due to be serviced. Please contact your landlord or local housing authority. |
T3R (Wireless) Thermostat & Receiver Box only | ||||
Thermostat is flashing ![]() ![]() | Wireless signal lost - Move the Thermostat to another location to try and restore communication. | |||
Thermostat is flashing ![]() ![]() | Check Receiver Box has power by pressing the button to switch boiler on. If Receiver Box has power, then no wireless binding data stored - Follow binding procedure in the installation guide or contact your installer. | |||
Receiver Box ![]() | Receiver Box is in binding mode - will time out of this mode after 3 minutes. | |||
T3M (OpenTherm) Thermostat only | ||||
An OpenTherm boiler can report alerts back to the Thermostat which can be useful when contacting an installer or maintenance engineer. You can view these in the 'OpenTherm® boiler alerts' menu. | ||||
Description | ID | Error code | OT Reading | |
Service request | 001 | 01SR | 0 = service not required 1 = service required | |
Low water pressure | 002 | 02WP | 0 = no WP fault 1 = WP fault | |
Gas/flame fault | 003 | 03GF | 0 = no GF fault 1 = GS fault | |
Air pressure fault | 004 | 04AF | 0 = no AP fault 1 = AP fault | |
Water Over Temperature | 005 | 05WT | 0 = no OVT fault 1 = OVT fault | |
OEM specific | 006 | 06OS | Boiler manufacturer specific code |