ECR International UTICA BOILERS PEG-C Series User's Information Manual

Gas fired hot water or steam heating boiler

Advertisement

Information and specifications outlined in this manual in effect at the
time of printing of this manual. ECR International reserves the right to
discontinue, change specifications or system design at any time without
notice and without incurring any obligation, whatsoever.
Check our website frequently for updates: www.ecrinternational.com
INFORMATION
MANUAL
SERIES PEG-C
GAS FIRED HOT WATER OR STEAM HEATING BOILER
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
USER'S
Utica Boilers
P.O. Box 4729 Utica, NY
13504
P/N 3741701, Rev. A [1/2011]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UTICA BOILERS PEG-C Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ECR International UTICA BOILERS PEG-C Series

  • Page 1 Information and specifications outlined in this manual in effect at the Utica Boilers time of printing of this manual. ECR International reserves the right to discontinue, change specifications or system design at any time without P.O. Box 4729 Utica, NY notice and without incurring any obligation, whatsoever.
  • Page 2 1 - GEnERal 1.1 General 1.3 WHAT TO DO SHOULD OVERHEATING OCCUR This boiler has few user serviceable parts. Maintenance Do not turn off or disconnect electrical supply to pumps. and Service must be completed by qualified agency. Shut off gas supply at location external to appliance. Determine if ignition system is electric or standing pilot 1.4 WHAT TO DO IF BOILER OR ANY PART HAS before any procedure is attempted.
  • Page 3: For Your Safety Read Before Operating

    2 - OpERaTInG InsTRUCTIOns InTERmITTEnT pIlOT sysTEm FOR yOUR saFETy REaD BEFORE OpERaTInG Wait 5 minutes for any gas to clear. Smell for gas, including near floor. If you smell gas, sTOp! Follow instructions on this page: “What To Do If you smell CaUTIOn Gas.”...
  • Page 4: For Your Safety Read Before Lighting

    3 - lIGhTInG InsTRUCTIOns COnTInUOUs pIlOT sysTEm FOR yOUR saFETy REaD BEFORE lIGhTInG. Find pilot. Follow metal tube from gas control. Pilot will be located on one of the burner tubes. See Figure 3-2. CaUTIOn Turn gas control knob counter clockwise to "pilot"...
  • Page 5: To Turn Off Gas To Appliance

    4 - TO TURn OFF Gas TO applIanCE 3-1 Continuous pilot Gas Valve 4.1 TO TURN OFF GAS TO APPLIANCE • Set thermostat to lowest setting. • Turn "OFF" all electric power to appliance if service is to be performed. •...
  • Page 6: General Instructions

    5 - GEnERal InsTRUCTIOns 5.1 SEASONAL START UP 5-1 Water line on steam Boiler • Before seasonal start up, it is advisable to have a competent service agency check boiler and scale in flues, clean burners, check gas input rate to maintain high operating efficiency.
  • Page 7 5 - GEnERal InsTRUCTIOns 5-4 Draft hood • Allow boiler to thoroughly cool and slowly refill to water line. Repeat process until blow off water is clear. WaRnInG Burn and scald hazard. Discharge may be boiling water. Take appropriate care to cool boiler before flushing.
  • Page 8: Cleaning Boiler Flueways

    Make certain that chips are not lodged in flue-ways. Utica Boilers P.O. Box 4729 Utica, NY 13504 Date of Installation: Boiler Model #: An ISO 9001-2008 Certified Company ECR International, Inc. Installed By: 2201 Dwyer Ave. Utica, NY 13501...