Appendix B: External Sensor And Relay Installation - Lorex QLR-0440 Series Instruction Manual

Digital video capture card
Hide thumbs Also See for QLR-0440 Series:
Table of Contents

Advertisement

APPENDIX B: External Sensor and Relay Installation

(1) Selection of sensor type
Choose Anode type (When it works, 0 ohm is remained) as a sensor and NO type (Normal Open type. When it works,
0 ohm is remained) as a Relay.
(2) Required Specification of Sensor connecting wire
Connection wire that has small internal resistance is recommended. Please refer to the following.
(1) Number of Sensor: 8 ea
(2) Voltage between sensor input and GND, when sensor input is opened: +5 Volt
(3) Terminal voltage: High = stand by, Low = Activated
(4) Max resistance for activation: 500 Ohm
(3) Example of operation test of external devices including a Light
- 51 -