Installs Easily
IMPORTANT!
• Please read all instructions carefully before beginning
installation. Save them for future reference.
• Before removing any wiring from your existing thermostat,
its wires must be labeled with their terminal designations.
• Ignore the color of the wires since they may not comply
with any standard.
1.
FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.
COMPATIBILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1. TOOLS REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2. LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3. REMOVING THE OLD THERMOSTAT . . . . . . . . . . . . . . . . . . . . . . . .
3.4. MOUNTING THE DP711TS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5. CONNECTING THE WIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6. WIRING DIAGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11
3.7. COMPLETING YOUR INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . .
4.
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1. SYSTEM MODE SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2. FAN MODE SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3. UP/DOWN ARROW CHANGE KEYS. . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1. TEMPERATURE ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2. CHANGING OTHER SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4. NAVIGATION KEYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5. DISPLAY ILLUMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6. AUDIBLE BEEP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7. ICONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.1. FLAME ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.2. SNOWFLAKE ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.3. LOW BATTERY ICON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8. HARDWARE RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9. SOFTWARE RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.10. SETTING THE TIME AND DAY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING: Use Energizer
Mt. Laurel, New Jersey 08054, USA
© 2012 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
®
ELECTRONIC THERMOSTAT
Set Day & Time
Choose Heat or Cool
Thank you for your confidence in our product. To obtain the best
results from your investment, please read these instructions
thoroughly and acquaint yourself with your purchase before
installing your new thermostat. Then follow the installation
procedures, one step at a time. This will save you time and
minimize the chance of damaging the thermostat and the systems
it controls.
These instructions may contain information beyond that required
for your particular installation. Please save for future reference.
2
4.11. TEMPORARY TEMPERATURE OVERRIDE. . . . . . . . . . . . . . . . . . . .
2
4.12. TEMPERATURE HOLD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
5.
2
5.1. DEFAULT TEMPERATURE PROGRAMS. . . . . . . . . . . . . . . . . . . . . .
2
5.2. PROGRAMMING THE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
5.2.1. COPY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
6.
3
6.1. FILTER USAGE MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2. SWING SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
6.3. TEMPERATURE CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
6.4. ENERGY USAGE MONITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
6.5. PROGRAM LOCK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.1. TO SET CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
6.5.2 TO LOCK SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
6.5.3. TO UNLOCK SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
7.
4
7.1. THE DISPLAY FORMAT 12/24 SWITCH #1. . . . . . . . . . . . . . . . . . .
4
7.2. SMART RECOVERY SWITCH #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
7.3. TEMPERATURE DISPLAY FORMAT F°/C° SWITCH #3. . . . . . . .
4
7.4. 5 MIN/2 MIN MINIMUM RUN TIME SWITCH #4 . . . . . . . . . . . . .
4
4
7.5. REPOSITIONING SWITCHES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
7.6. GAS/ELECTRIC JUMPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
8.
4
9.
5
10. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
®
or DURACELL
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
www.luxproproducts.com
DP711TS
Easy as
1–2–3
PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADVANCED FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SETUP OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BATTERIES AND MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TECHNICAL ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
®
Alkaline Batteries Only.
5
5
5
5
5
6
6
6
6
7
7
7
7
7
7
7
7
7
8
8
8
8
8
8
8
52120

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMART TEMP DP711TS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PurePro SMART TEMP DP711TS

  • Page 1 DP711TS SMART TEMP ® ELECTRONIC THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS Easy as 1–2–3 Installs Easily Set Day & Time Choose Heat or Cool Thank you for your confidence in our product. To obtain the best IMPORTANT! results from your investment, please read these instructions thoroughly and acquaint yourself with your purchase before •...
  • Page 2: Installation

    MODE SWITCH DP711TS LIGHT FAN SWITCH BUTTON 1. FEATURES Ask your dealer for other PUREPRO thermostats to control those systems. • Extra Large Hybrid Touch Screen Display • Audible Touch Confirmation 3. INSTALLATION • EL Display Illumination Please read all instructions carefully before •...
  • Page 3: Removing The Old Thermostat

    • Do not install it where there are unusual heating 7. Press up on the conditions, such as: in direct sunlight; near a thumb latch at the lamp, radio, television, radiator, register, or bottom of thermostat fireplace; near hot water pipes in a wall; near a and separate the stove on the other side of a wall.
  • Page 4 18. Verify that the system and its fan are 4.3.2. CHANGING OTHER SETTINGS operating properly. When set to a high If there are many choices for a value, usually that temperature, the heating system should provide setting will automatically advance by holding one warm air after a short time.
  • Page 5: Software Reset

    4.9. SOFTWARE RESET • OVERRIDE will be automatically canceled at the start of the next program period. This reset is disabled while the touchscreen is locked. When activated it will reset all • OVERRIDE will be cancelled if the set programmable values and settings including the temperature is adjusted to its programmed value lock code and clock, to their default values.
  • Page 6: Swing Setting

    • Set the mode switch to HEAT to program the convenient for you. unit for controlling your heater. Set the mode 5.2.1. COPY switch to COOL to program the unit for controlling COPY will copy the previous days programs into your air conditioner.
  • Page 7 • Use UP/DOWN arrows to adjust. • Touch to accept new code; ENTER OLD CODE will be visible. • Touch to return to main display. EXIT • Touch to return to main display. EXIT 6.3. TEMPERATURE CALIBRATION 6.5.2. TO LOCK SETTINGS •...
  • Page 8: Warranty

    • Maximum Smart Recovery time is one hour. from the wall by pressing up on the thumb latch at the bottom of thermostat and swinging the body • The Smart Recovery temperature set point must up and away to remove it from the wall. be achievable.
  • Page 9: Cooling Systems

    3.6. WIRING DIAGRAMS 2 + 3 WIRE HEATING SYSTEMS COOLING SYSTEMS JUMPER JUMPER PROVIDED PROVIDED NOTE: "G" WIRE IS OMITTED FOR 2 WIRE SYSTEMS HEATING/COOLING SYSTEMS HEATING/COOLING SYSTEMS 5 + 6 Wire 2 Transformers 4 + 5 Wire 1 Transformers JUMPER JUMPER REMOVED...
  • Page 10 2 WIRE, 24 VOLT AND MILLIVOLT HEAT ONLY SYSTEMS RC-RH SYSTEM COMMON JUMPER PROVIDED WIRING DIAGRAM OPTIONAL NOTES 24 VOLT (APPLIES TO ALL HEAT HEAT TRANSFORMER DRAWINGS) 120 VAC * The DASHED wires are optional depending on your system type. * Verify whether “C”, “X”...
  • Page 11 4 WIRE HEATING AND COOLING SYSTEM RC-RH SYSTEM COMMON JUMPER PROVIDED OPTIONAL 24 VOLT HEAT SYSTEM COMPRESSOR TRANSFORMER 120 VAC 5 WIRE SYSTEM HEATING AND COOLING - 2 TRANSFORMERS RC-RH SYSTEM COMMON JUMPER REMOVED OPTIONAL 24 VOLT 24 VOLT HEAT COOLING COOL HEAT...
  • Page 12 5.2. PROGRAMMING THE UNIT To ease reprogramming later, record your thermostat’s programs and settings in the table provided below. HEAT COOL PERIOD TIME TEMP. TIME TEMP. MORN THURS HEAT COOL PERIOD NIGHT TIME TEMP. TIME TEMP. MORN MORN NIGHT NIGHT MORN MORN TUES...