Download Print this page
Cisco Nexus 9348GC-FX3 Hardware Installation Manual
Cisco Nexus 9348GC-FX3 Hardware Installation Manual

Cisco Nexus 9348GC-FX3 Hardware Installation Manual

Aci-mode switch
Hide thumbs Also See for Nexus 9348GC-FX3:

Advertisement

Quick Links

Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation
Guide
First Published: 2024-02-29
Last Modified: 2024-10-21
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

loading
Need help?

Need help?

Do you have a question about the Nexus 9348GC-FX3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cisco Nexus 9348GC-FX3

  • Page 1 Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide First Published: 2024-02-29 Last Modified: 2024-10-21 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 © 2024 Cisco Systems, Inc. All rights reserved.
  • Page 3: Table Of Contents

    Installing the Switch into a Two-Post Rack Using the NXK-ACC-KIT-1RU Rack-Mount Kit Installing the Airflow Sleeve (N9K-AIRFLOW-SLV) Grounding the Chassis Starting the Switch C H A P T E R 4 Connecting the Switch to the ACI Fabric Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 4 Switch and Module Weights and Quantities Transceiver and Cable Specifications Switch Power Input Requirements Power Specifications 350-W AC Power Supply Specifications 350-W PHV Power Supply Specifications 440-W DC Power Supply Specifications Power Cable Specifications Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 7: Overview

    Overview, on page 1 Overview The Cisco Nexus 9348GC-FX3 switch (N9K-C9348GC-FX3) is a 1-rack unit (RU) switch that supports 696 Gbps of bandwidth and over 517 Mpps. The 48 1GBASE-T downlink ports on the 9348GC-FX3 can be configured to work as 100-Mbps or 1-Gbps ports. The 4 ports of SFP28 can be configured as 1/10/25-Gbps and the 2 ports of QSFP28 can be configured as 40- and 100-Gbps ports, or a combination of 10-, 25-, 40, and 100-Gbps connectivity, offering flexible migration options for spine-leaf-APIC deployment in data centers.
  • Page 8 The following figure shows the switch features on the port side of the chassis. LEDs SFP28 ports (4) QSFP28 ports (2) 100M/1G RJ45 ports (40) Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 9 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 10 Overview Overview Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 11: Preparing The Site

    Altitude Requirements Altitude rating is 10,000 ft (3048 m). For China, it is 6,562 ft (2000 m). Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 12: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal, when applicable. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 13: Shock And Vibration Requirements

    Rack and Cabinet Requirements Install these types of racks or cabinets for your switch: • Standard perforated cabinets • Solid-walled cabinets with a roof fan tray (bottom-to-top cooling) • Standard open four-post Telco racks Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 14 Preparing the Site Rack and Cabinet Requirements Work with your cabinet vendors to determine which of their cabinets meet these requirements or see the Cisco Technical Assistance Center (TAC) for recommendations: • Use a standard 19-inch (48.3-cm), four-post Electronic Industries Alliance (EIA) cabinet or rack with mounting rails that conform to English universal hole spacing per section 1 of the ANSI/EIA-310-D-1992 standard.
  • Page 15: Installing The Switch Chassis

    Starting the Switch, on page 24 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series content for important Safety Information. Warning Statement 1071 Warning Definition...
  • Page 16 Only an instructed person or skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of an instructed or skilled person. There are no serviceable parts inside. To avoid risk of electric shock, do not open. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 17 This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 18: Installation Options With Rack-Mount Kits

    Install the switch using these rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 19: Airflow Considerations

    50 to 60 Hz. Caution To prevent loss of input power, ensure the total maximum loads on the circuits supplying power to the switch are within the current ratings for the wiring and breakers. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 20: Unpacking And Inspecting The Switch

    Note You must supply the eight 10-32 or 12-24 screws required to mount the slider rails and switch to the rack. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 21 The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 22 To attach the rails to the rack (see the figure). Tighten 12-24 screws to 30 in-lb (3.39 N·m) of torque and tighten 10-32 screws to 20 in-lb (2.26 Nm) of torque. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 23 Holding the chassis level, insert screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of six screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the figure). Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 24: Installing The Switch Into A Two-Post Rack Using The Nxk-Acc-Kit-1Ru Rack-Mount Kit

    • Front rack-mount brackets (2) • Rear rack-mount brackets (2) (not needed for this procedure) • Slider rails (2) (not needed for this procedure) • M4 x 0.7 x 8-mm Phillips countersink screws (12) Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 25 The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 26 Insert the switch into the rack and attach it as follows: a) Holding the switch with both hands, position the brackets on the switch between the cabinet posts (see the following figure). Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 27 Tighten the 10-32 screws to 20 in-lb (2.26 N·m) or tighten the 12-24 screws to 30 in-lb (3.39 N·m). Step 4 If you attached a grounding wire to the chassis grounding pad, connect the other end of the wire to the facility ground. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 28: Installing The Airflow Sleeve (N9K-Airflow-Slv)

    You supply the screws to mount the airflow sleeve. Before you begin • Verify that your shipment is complete. • Install your rack in a secure location. Procedure Insert the airflow sleeve into the rack and attach it: Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 29: Grounding The Chassis

    This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 30: Starting The Switch

    Prepare the other end of the grounding wire and connect it to the facility ground. Starting the Switch Start the switch by connecting it to its dedicated power source. If you need n+n redundancy, connect each power supply in a switch to a different power source. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 31 3. Place the power cable negative-wire terminal ring on the negative terminal for the power source and secure them with a terminal nut. 4. Place the power cable positive-wire terminal ring on the positive terminal for the power source and secure them with a terminal nut. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 32 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 33: Connecting The Switch To The Aci Fabric

    As shown in the following figure, each APIC is connected to one or two leaf switches and each leaf switch should be connected to every spine switch in the same fabric. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 34: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 35: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs.
  • Page 36 Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 37: Connecting Leaf Switches To Spine Switches

    Connecting the Switch to the ACI Fabric Connecting Leaf Switches to Spine Switches • For Cisco SFP+ Active Optical Cables, insert the transceiver on the cable into a downlink optical port on a leaf switch. • For a 10GBASE-T copper cable, insert the RJ-45 connector on the cable into a downlink BASE-T port on a leaf switch.
  • Page 38: Installing A Gigabit Ethernet Module (Gem)

    Replacing an Existing Switch in the ACI Fabric To replace an existing switch in the ACI fabric, see "Upgrading the Switch Hardware" in the Cisco APIC Installation and ACI Upgrade and Downgrade Guide. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 39: Setting Up An Optional Console Interface

    DB-9 connector on the other end of the cable to the serial port on the console device. What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 40: Maintaining Transceivers And Optical Cables

    • Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 41: Replacing Components

    • There must be an earth ground connection to the chassis that you are installing the replacement module. AC power supplies connected to AC power sources are automatically grounded through their power cable. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 42: Replacing A High Voltage (Hvac/Hvdc) Power Supply

    • There must be an earth ground connection to the chassis in which you are installing the replacement power supply. HVAC/HVDC power supplies connected to AC power sources are automatically grounded by their power cable when connected to the power supply and AC power source. HVAC/HVDC power Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 43: Replacing A Dc Power Supply

    Verify that the power supply is operational by making sure that the power supply LED is green. Replacing a DC Power Supply You can replace an DC power supply during operations so long as the other power supply provides power to the switch. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 44 Note If the power supply does not fit into the open slot, turn the module over before sliding it carefully into the open slot. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 45 Attach the power connector block end of the power cable to the electrical outlet on the front of the power supply. d) Turn on the circuit breaker for the power source. e) Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 46 Replacing Components Replacing a DC Power Supply Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 47: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 48: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 49: System Specifications

    32 to 104°F (0 to 40°C) Ambient nonoperating –40 to 158°F (–40 to 70°C) 5 to 95% Relative Nonoperating humidity Operating 5 to 90% Altitude Operating 0 to 13,123 feet (0 to 4,000 meters) Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 50: Switch Dimensions

    – 350-W PHV port-side exhaust (blue) (NXA-PHV-350W-PE) – 440-W DC port-side intake (burgundy) (NXA-PDC-440W-PI) – 440-W DC port-side exhaust (blue) (NXA-PDC-440W-PE) Transceiver and Cable Specifications To see the transceiver specifications and installation information, see https://www.cisco.com/c/en/us/support/ interfaces-modules/transceiver-modules/products-device-support-tables-list.html. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 51: Switch Power Input Requirements

    Maximum inrush current 33 A (sub-cycle duration) Maximum hold-up time 12 ms at 350 W Power supply output voltage -54 VDC Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum certified) Form factor RSP1 Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 52 20 A The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on -36 VDC. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 53: Power Cable Specifications

    CAB-250V-10A-CN 250 V, 10 A, 8.2 feet (2.5 m) South Africa CAB-250V-10A-ID 250 V, 10 A, 8.2 feet (2.5 m) Switzerland CAB-9K10A-SW 250 VAC, 10 A, MP232 plug, 8.2 feet (2.5 m) Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 54: Regulatory Standards Compliance Specifications

    This table lists the regulatory standards compliance for the switch. Table 3: Regulatory Standards Compliance: Safety and EMC Specification Description Regulatory compliance Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 55 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 56 System Specifications System Specifications Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 57: Appendix

    Amber Port admin state is 'Disabled, or the SFP is absent, or both. Port admin state is 'Enabled' and SFP is present, but interface is not connected. Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 58: Fan Module Leds

    • Power supply is installed in the chassis but was disconnected from the power source. Flashing amber Power supply is installed without a connection to a power source. (10 seconds) then amber Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 59 LEDs LEDs OK LED FAIL or FAIL/ID Status Amber Power supply failure—possibly one of these conditions: • Over voltage • Over current • Over temperature • Power supply fan failure Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 60 LEDs LEDs Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 61: Additional Kits

    Not applicable Hazardous substances list for customers in China This table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...
  • Page 62 Additional Kits Additional Kits Cisco Nexus 9348GC-FX3 ACI-Mode Switch Hardware Installation Guide...