  • Page 1 Super6 Owner’s manual...
  • Page 2 Pay particular attention to the power cord at the plug and where it exits the back of the unit. The Farad Super6 is designed for consumer audio only and for use with DC cables with a maximum length of 100cm.
  • Page 3 Product prior to expiration of the 24 months term, this warranty shall terminate in its entirety upon the date of such transfer. In addition, Farad power supplies does not warrant in any way products which are purchased from anyone who is not an authorized Farad power supplies dealer or which have not been...
  • Page 4 Farad power supplies handles a “carry in” warranty, so all costs for shipping hence and forth will have to be paid by customer. In the alternative, Farad power supplies may at its sole option either re-...
  • Page 5 Getting started The Super6 is a top level low noise dual linear regulated supercapacitor power supply. It is capable of delivering a maximum of 6A current at its rated voltage output. Operating features Double regulated supercapacitor linear power supply High inductance double shielded toroidal power transformer Pi-filter supply input with 48.000uF of standard electrolytic capacitors...
  • Page 6 Take care the Trigger mode and earth connection are set properly. Connect the DC cable to the Super6 and load. Plug in the power cord in the IEC connector (figure 1, position 7) and the other end in an appropriate AC outlet. The led will flash blue and red a couple of times, and after that starts fading on and off red, it is charging the supercapacitors.
  • Page 7 At the Farad website you can find a list of confirmed devices with proper voltage and connector ratings. If you are not sure, you can always try out with a Farad power supply, it is fully protected, so nothing will be damaged if too much current will be drawn. If it works it is ok.
  • Page 8 Power failure / tripped circuit breaker The Super6 uses a thermal magnetic circuit breaker (TMCB) for protection. This circuit breaker typically sounds better than any fuse we know on the market. When the TMCB trips due to a failure, inside the enclosure it can be resetted after the failure has been taken away.
  • Page 9 Identification of controls FIGURE 1: Front and back of the Super6 power supply, controls and connections Indicator LED. The front LED has several modes: Solid blue: Power supply is ready, voltage present at output. Solid blue and red (purple): AC input voltage too low, or output voltage too low (short), no critical error, turns into error (d) after 3 seconds.
  • Page 10 AC voltage is present at the wall outlet. If this is the case and led still does not light up, please go to your Farad dealer or contact Farad power supplies directly.
  • Page 11 Front LED stays fading red and does not turn blue at startup Error in the supercapacitor charging circuit, or too low input voltage. Check power cable and AC mains power. If this is ok, please go to your dealer or contact Farad power supplies directly.
  • Page 12: Specifications

    Any other voltage between 5V and 24V available on special request All specifications are an indication and valid at the time of printing of this manual. Farad power supplies reserves the right to make any changes at any time without prior notice.