Download Print this page

Advertisement

Quick Links

Quick Start Guide
SymNet™ DSP
Before You Begin
What Ships in the Box
A SymNet hardware device.
SymNet Designer CD-ROM (Windows).
A SymLink patch cable.
A ferrite clamp
A detachable power cord.
This Quick Start Guide.
What You Need to Provide
A Windows PC with 300MHz or higher
Pentium and:
• WIN 98SE or WIN 2000.
• 10-15MB free storage space.
• 1024x768 graphics capability
• 16 bit or higher colors
• CD ROM drive or Internet connection.
• 64MB RAM (WIN 98SE), 128MB RAM
(WIN 2000).
An available serial port capable of oper-
ating at 57.6 or 115.2 kilobaud.
A cable to connect the RS-232 serial
port of your PC to SymNet's front panel
RS-232 input. The SymNet RS-232
input is a female DB-9 connector.
Getting Help
SymNet Designer, the Windows applica-
tion that controls all SymNet hardware,
includes a help module which acts as a
complete user's guide for both hardware
and software. A printable copy is also
available at www.symetrixaudio.com
If you have questions beyond the scope
of the help module, contact our Customer
Support Group in the following ways:
Tel
(425) 778-7728
8:00 am to 4:30 pm
Monday through Friday,
Pacific Time
Email
tech@symetrixaudio.com
Web
www.symetrixaudio.com
This device complies with part 15 of
the FCC Rules. Operation is subject
to the following two conditions: (1)
This device may not cause harmful
interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
This Class A Digital apparatus meets all
requirements of the Canadian Interference-
Causing Equipment Regulations
Cet appariel numerique de la classe
A respecte toutes les Exigences du
Reglement sur le materiel brouilleur du
Canada.
application that controls all SymNet hardware go to: www.symetrixaudio.com
Important Safety Instructions.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings.
Install only in accordance with the
manufacturer's instructions.
8. Do not install near any heat sources
such as radiators, heat registers,
stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of
the polarized or grounding-type plug. A
polarized plug has two blades with one
wider than the other. A grounding type
plug has two blades and a third ground-
ing prong. The wide blade or the third
prong are provided for your safety. If
the provided plug does not fit into your
outlet, consult an electrician for replace-
ment of the obsolete outlet.
10. Protect the power cord from being
walked on or pinched particularly at
plugs, convenience receptacles, and
the point where they exit from the appa-
ratus.
11. Only use attachments/accessories
specified by the manufacturer.
12. Use only with the cart,
stand, tripod, bracket,
or table specified by the
manufacturer, or sold
with the apparatus. When
a cart is used, use cau-
tion when moving the cart/apparatus
combination to avoid injury from tip-
over.
13. Unplug this apparatus during lightning
storms or when unused for long periods
of time.
14. Refer all servicing to qualified service
personnel. Servicing is required when
the apparatus has been damaged in
any way, such as power-supply cord
or plug cord is damaged, liquid has
been spilled or objects have fallen into
the apparatus, the apparatus has been
exposed to rain or moisture, does not
operate normally, or has been dropped.
To download the latest version of SymNet Designer, the Windows
WARNING:
AVIS:
SEE OWNERS MANUAL. VOIR CAHIER D'INSTRUCTIONS.
No user serviceable parts inside. Refer servicing to qualified service personnel.
Il ne se trouve a l'interieur aucune piece pourvant entre reparée l'usager.
S'adresser a un reparateur compétent.
The lightning flash with arrowhead symbol
within an equilateral triangle is intended to
alert the user of the presence of uninsu-
lated "dangerous voltage" within the prod-
uct's enclosure that may be of sufficient
magnitude to constitute a risk of electric
shock to persons. The exclamation point
within an equilateral triangle is intended to
alert the user of the presence of important
operating and maintenance (servicing)
instructions in the literature accompanying
the product (i.e. this quick start guide).
CAUTION
do not use the polarized plug supplied with
the unit with any extension cord, recep-
tacle, or other outlet unless the prongs can
be fully inserted.
Power Source.
Matrix hardware uses a switching power
supply that automatically adjusts to the
applied voltage. Ensure that your AC
mains voltage is somewhere between 100-
240 VAC, 50-60 Hz (200-240 VAC, 50 Hz
for some export markets - refer to rating on
rear panel). Use only the power cord and
connector specified for the product and
your operating locale. A protective ground
connection, by way of the grounding con-
ductor in the power cord, is essential for
safe operation.
User Serviceable Parts.
are no user serviceable parts inside the
SymNet™ Audio Matrix. In case of failure,
customers inside the U.S. should refer all
servicing to the Symetrix factory. Custom-
ers outside the U.S. should refer all servic-
ing to an authorized Symetrix distributor.
Distributor contact information is available
online at www.symetrixaudio.com.
SymNet
TM
Audio Matrix
1/13
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE
THIS EQUIPMENT TO RAIN OR MOISTURE
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
To prevent electric shock,
SymNet™ Audio
There

Advertisement

loading
Need help?

Need help?

Do you have a question about the SymNet DSP and is the answer not in the manual?

Questions and answers

Summary of Contents for Symetrix SymNet DSP

  • Page 1 U.S. should refer all to the following two conditions: (1) storms or when unused for long periods servicing to the Symetrix factory. Custom- This device may not cause harmful of time. ers outside the U.S. should refer all servic- interference, and (2) this device must ing to an authorized Symetrix distributor.
  • Page 2: Audio Matrix

    2/13 SymNet™ Audio Matrix SymNet™ Designer The Symetrix SymNet™ Audio Matrix is a family of SymNet™ Designer is an easy to use graphical user net work linkable audio matrix processors intended for the interface (GUI) that uses drag-and-drop techniques to installed sound market.
  • Page 3: Hardware Installation

    Remarks Binary outputs (relay All use Euroblock con nectors. Connectors come in 3-pin modules. Connectors and open collector) and Symetrix part number 039003. included with unit. analog control inputs SymLink RJ-45 CAT-5 shielded net work Uses standard RJ-45 ‘straight-through’ wiring. 10 cabling required.
  • Page 4: Rear Panel (Left)

    THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. TRANSMIT RECIEVE DEVICE SymLink FABRIQUÉ AUX E.-U. PAR SYMETRIX, INC. LYNNWOOD, WA ---- RS-485 ---- --- RELAY 3 --- --- RELAY 2 --- --- RELAY 1 --- CONFIG PAS DES ELEMENTS SERVIABLE PAR UTILISATEUR Rear Panel (right)
  • Page 5 SymNet Quick Start Guide Audio Matrix SymNet™ DSP To download the latest version of SymNet Designer, the Windows application that controls all SymNet hardware go to: www.symetrixaudio.com Hardware Installation... 5/13 DIP Switch Settings An eight-position DIP switch is located in the middle of the rear panel of the Note: after changing any DIP switch SymNet™...
  • Page 6 SymNet Quick Start Guide Audio Matrix SymNet™ DSP To download the latest version of SymNet Designer, the Windows application that controls all SymNet hardware go to: www.symetrixaudio.com Hardware Installation... 6/13 Analog Input / Output Connections Item Description Details Remarks Analog Balanced-bridging input Input impedance: For unbalanced use, either refer ence the minus...
  • Page 7 Terminate a wire by clicking on the terminating connection point or by hit ting the ESC The Symetrix SymNet™ Designer software provides real- time control over multiple audio functions from a Win dows key or right mouse button. Right click on an existing wire to 98/2000 PC environment.
  • Page 8: Warranty

    In no event will Symetrix be liable for any incidental or...
  • Page 9 Styrofoam peanuts. Be sure there is enough clearance in the box to protect the rack ears. We won't return the unit in anything but Symetrix packaging for which we will have to charge you. If the problem is due to operator misuse or error, you will have to pay for both parts and labor.
  • Page 10: Declaration Of Conformity

    © 2001, 2002, Symetrix, Inc. All rights reserved. Printed in the United States of America. Symetrix Part Number 538X8S1A06. The information in this Quick Start Guide is subject to change without notice. Symetrix, Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor is it liable for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
  • Page 12: Common Problems And Solutions

    By default it should take you into the C:\Program Files\ transmit connected to the first units receive to complete the ring. Symetrix\SymNet Designer X.X\Upgrade folder. Select the most All SYMLINK ACTIVE green LEDs should be lit on the front of recent SNMvXXXX.bin file and click Open.
  • Page 13 : As of SymNet Designer software version 2.0, a maximum of 32 Rings, each having 16 Addresses, are possible. For the sake of space, only switch settings for the first 8 Rings or Addresses are pictured. SymNet DSP BOOT MODE BOOT MODE...