Download Print this page
Woodbridge AIC5910 Installation Instructions Manual

Woodbridge AIC5910 Installation Instructions Manual

Cold plunge tub

Advertisement

Quick Links

Installation Instruction
READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT
INSTRUCTIONS THAT, IF IGNORED, COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING
OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.
Cold Plunge Tub
2 PEOPLE ARE REQUIRED TO LIFT AND DURING
TWO PEOPLE
LIFT REQUIRED
ENTIRE INSTALLATION OF THIS PRODUCT
www.woodbridgebath.com
Model: AIC5910
AIC6710
1 1 1 1
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the AIC5910 and is the answer not in the manual?

Questions and answers

Summary of Contents for Woodbridge AIC5910

  • Page 1 Installation Instruction Cold Plunge Tub Model: AIC5910 AIC6710 READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT INSTRUCTIONS THAT, IF IGNORED, COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.
  • Page 2 www.woodbridgebath.com 2 2 2 2...
  • Page 3: Working Principle

    Product Name: Cold Plunge Tub Model: AIC5910 AIC6710 AIC5910 AIC6710 67" 59" 17 3/4 17 3/4 " " " " " " 31 1/2 " 29 1/2 " 59" 67" Accesories in Tub package: ●Insulated Tub Cover*1 ●Black Hard Hose*2 4.Working principle...
  • Page 4 5.Installa�on Instruc�on Chiller installa�on ① Install the chiller in a stable place to avoid the impact of water level backflow. The ice tub’s inlet hole should be set to a higher level than the inlet of the chiller. ② Install the chiller in a clean place. Avoid too much debris gets into the tub to block the chiller system. ③...
  • Page 5 6.Cold Plunge Usage ① Hoses connec�on Connect the hoses as shown in the picture. Inlet Outlet Outlet Inlet 1. The cold plunge should be installed on a stable pal�orm to avoid the influence of back flow of water level. 2.lf the hoses are too narrow, they will affect the water flow and cause the chiler system to malfunc�on or underperform. 3.
  • Page 6 6. The ozone generator's working life is ten thousand hours. A�er reaching its limit, please replace it with a new ozone generator. 7.Technical Specifica�on Cold plunge Parameters Model AIC5910 AIC6710 Outer dimensions 59ʺ x 29-1/2ʺ x 23ʺ 67ʺ x 31-1/2ʺ x 23ʺ...
  • Page 7: Warranty

    WARRANTY WOODBRIDGE Bathtub, Whirlpool/Air Bubble Massage Tub, Cold Plunge,1 Year limited to be free of defects in material and workmanship. Sauna room and Sauna Tent : 1 Year limited to be free of defects in material and workmanship. Toilet and Bidet : 1 Year limited to be free of defects in material and workmanship.
  • Page 8 DO NOT USE: Abrasive sponges or cloth. Never use steel, wool, or wired brushes that will permanently scratch the Retain these installation instructions for future reference! Thank you for using WOODBRIDGE products! WOODBRIDGE California (Norwalk)Distribu�on Center 15600 Blackburn Ave,Norwalk,CA 90650 New Jersey (Somerset)Distribu�on Center...

This manual is also suitable for:

Aic6710