Page 1
SPARE AIR USER’S INSTRUCTIONS EMERGENCY BREATHING DEVICE FOR INDUSTRIAL SAFETY APPLICATIONS SUBMERSIBLE SYSTEMS, INC. Phone: (714) 842-6566 www.submersiblesystems.com THE LEADER IN SELF-RESCUE BREATHING SYSTEMS 7/24 G:\Mktg\IS\IS user inst...
• SPARE AIR is packaged fully assembled and is ready to use after it has been filled with air. User needs to purchase a Refill Adapter – see options below. Other refill options are available such as a Hand Pump, and small portable compressors.
(Use a high-pressure, breathing air quality air compressor designed to fill air systems.) WARNING: If the SPARE AIR Check Valve Refill Port or Refill Adapter threads are damaged or worn these parts will require replacement. Continued use may cause injury.
MOUNTING INSTRUCTIONS FOR HOLSTER WITH VELCRO BACKING: CAUTION: SPARE AIR units should be mounted on a flat surface. It is not recommended to mount them on the ceiling or anywhere above waist level to protect passengers against impact if they come unattached.
1 to 1 vinegar & water solution for 3 hours to loosen any corrosion. Place SPARE AIR in a protective container (plastic bag or box) to keep unit clean and to secure loose parts. Pack in your check or carry-on luggage.
If a leak or damage is found at any point the unit should be referred for Overhaul Service. • No matter how often the unit has been used, or even if the unit has not been used at all, the Spare Air requires tank inspection and regulator overhaul every 5 years.
NOTE: Industry guidelines recommend replacing air in cylinders annually. SERIALIZATION: All SPARE AIR systems are identified with individual serial numbers. Serial numbers are located on the regulator to the right of the mouthpiece. SPARE AIR SPECIFICATIONS...