Mediana i50 User Manual

Mediana i50 User Manual

Body composition analyzer

Advertisement

Quick Links

Body Composition Analyzer
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mediana i50

  • Page 1 Body Composition Analyzer USER MANUAL...
  • Page 2: About This Manual

    About this manual This manual explains how to install and use I50. Please refer to WARNING and CAUTION signs where users need to be extra careful while using I50. Before using the product, users should carefully read this manual including precautions.
  • Page 3: Warranty

    Purchase date • The warranty is not valid if your issue falls into any of the following circumstances. - If non-MEDIANA staff or service provider performs unauthorized repair, installation, transport, or maintenance - When the product is damaged by other equipment...
  • Page 5: Table Of Contents

    Body Composition Analyzer Contents 1. Description 1.1. Basic Component 1.2. Install the product 1.3. Accessory 1.4. Connection of external equipment 2. Using Product 2.1. Name and Characteristics of Parts 2.2. Safety Precautions 2.3. Power On/Off 2.4. Body Composition Measurement 2.5. Checking Result 3.
  • Page 6: Precautions For Use

    • Be sure not to let this product in direct contact with other electronic devices in power. It may cause a spark hazard. (W0014) • Use the model adapter provided by MEDIANA. Use of other adapters may cause equipment malfunction. (W0025) • Do not touch signal input, signal output or other connectors, and the patient simultaneously.
  • Page 7 • Turn on the power of other inspection devices first, when connecting I50 to the inspection devices. If you want to turn off I50, power off the inspection devices first this time, then I50 later. Electrical shock of the equipment can be minimized.
  • Page 8: Description

    1. Description Body composition analyzer I50 is a bioelectrical body composition analyzer which estimates body composition parameters based on bioelectrical impedance analysis (BIA). This device calculates and estimates body composition parameters by using weight and segmental impedance and frequency. Body composition analysis results may be of value to health care professionals in their management environments.
  • Page 9: Install The Product

    A. After unpacking the box, remove the packing pad and take out the I50. Raise the upper body and fix it by screwing the fixing bolt. Once the upper body is fixed, cover the front and rear covers of the hinge and secure it by screwing.
  • Page 10 1. Description 1.2. Install the product D. Make sure the air bubble in the level indicator is centered by turning the height adjustment screws. Equipment should be leveled and installed on flat floor. If it is not leveled, it may cause a risk of stumbling injury to the examinee, product damage, or inaccurate measurement control.
  • Page 11: Accessory

    All products are treated as full optioned ones in this manual, so please refer to the configuration table below, if products operate wrongly. Option I50 Basic Configuration √ √ √...
  • Page 12 1. Description 1.4. Connection of external equipment B. Connecting Barcode Reader Barcode reader can be used to enter the subject’s ID. ① Power off the equipment. ② Connect the USB cable to the right USB port on the back of the product. ③...
  • Page 13 1. Description 1.4. Connection of external equipment C. Communications The device can use the following communications. Wi-Fi Chipset RTL8192CU Wireless IEEE 802.11b, IEEE 802.11g, IEEE 802.11n Frequency 2.4GHz Connector RJ45 Directional Half/Full Duplex Baud rate 10/100Mbps Standard IEEE 802.3/802.3u Supports power down mode / Supports under Link Down power saving mode 50 Body Composition Analyzer User Manual...
  • Page 14: Using Product

    2. Using Product 2.1. Name and Characteristics of Parts 2. Using Product 2.1. Name and Characteristics of Parts A. Front Touch LCD Power Button Rod electrode rotating unit Hand electrode rotation unit Hand electrode contact unit Weight measurement and Foot electrode Body joint unit (For packaging) Horizontal...
  • Page 15 2. Using Product 2.1. Name and Characteristics of Parts ○ Mechanical Feature • The size of this product is 472(W) X 888(D) X 1167(H) (mm) High-end device for the hospital and medical specialist, simple and easy to operate with a 10.4 inch full-touch screen. ○...
  • Page 16: Safety Precautions

    2. Using Product 2.2. Safety Precautions 2.2. Safety Precautions A. Display Item Symbols Description Symbols Description Manufacturer Manufacture Date Product configuration Product serial number number Serial Port Connection type: LAN Connection type: Printer Connection type: USB private USB B. Safety Sign Symbols Description Symbols...
  • Page 17: Product Category

    2. Using Product 2.2. Safety Precautions C. Product Category Protection type against electric shock CLASS I Degree of protection against electric shock BF type applied part(hand, foot electrodes) Same degree of water protection as shell coverings Degree of protection against immersion that offer no liquid protection, IPX0.
  • Page 18 2. Using Product 2.2. Safety Precautions WARNING • Measurement is prohibited for individuals with an internally implanted Pacemaker. (W0016) • Measurement is prohibited for those whose use of electrodes may cause skin problems. (W0017) • Jumping or playing on the footplate is prohibited due to possible personal injury. (W0018) •...
  • Page 19: Power On/Off

    2. Using Product 2.3. Power On/Off 2.3. Power On/Off Make sure that the product is working properly, before using it. The following explanation helps with how to operate the power button. A. Power On With the switch on the back of the product turned on, press power button or more than 1 second. Then, it starts and the loading screen will be displayed after the normal operation test.
  • Page 20: Body Composition Measurement

    2. Using Product 2.4. Body Composition Measurement 2.4. Body Composition Measurement 1. When you step on the weighing platform while [the home screen] is turned on, it will automatically start to measure weight first. - If you take your socks off and stand on your feet, you can easily proceed with body composition measurement after measuring weight.
  • Page 21 2. Using Product 2.4. Body Composition Measurement 4. Input necessary user information for measurement and press Next - For non-member use, select Gender and enter Height and Age. - For new registration,select Gender and enter Height and Age. Name, Waist circumference and Hip circumference are optional inputs.
  • Page 22 2. Using Product 2.4. Body Composition Measurement 5. Take a proper measuring posture following voice and screen guidance. Arm should not touch armpit. Stretch arms as far as possible without bending. Grip the hand electrodes with bare hands. If thighs come in contact, wear a pair of shorts or swimsuits to prevent them touching each other.
  • Page 23: Checking Result

    [the result screen] using [the button of bottom]. By pressing the QR code button from the device, it displays the QR code which shows the body composition results. You can manage results by scanning the code through Mediana app, which then will transfer the data to your smartphone. QR Code button...
  • Page 24 2. Using Product 2.5. Checking Result B. Segmental The segmental analysis shows measurements of muscle mass and body water for each of the left arm, right arm, trunk, left leg, and right leg. Right Arm(RA) Muscle Analysis Right Arm(RA) Body Water Analysis Left Arm(LA) Muscle Analysis Left Arm(LA) Body Water...
  • Page 25 - Screen can be switched by touching buttons or buttons on the top right corner of the screen. • MEDIANA score assesses how healthy the Status screen user is utilizing MEDIANA’s own patented display button technologies based on measuring body fat and muscle mass.
  • Page 26 2. Using Product 2.5. Checking Result D. Body Composition Change Changes of weight, muscle mass, body fat percentage and total body water can be sorted by period. - Press button to reveal / hide each item. Weight Muscle Body Fat Body Water (kg) (kg)
  • Page 27: Setting

    3. Setting 3.1. Menu 3. Setting 3.1. Menu Helps you to manage I50 settings. A. Configuration Introduction Press on the home screen and press to enter the set-up menu. MENU • See below for how to control screen display or time / date settings.
  • Page 28: Database Result

    3. Setting 3.2. Database result 3.2. Database result Stored measurement result data is listed in time order starting from the top. DB function selection button DB number display section Selected check button Detailed result show button Individual selection check button Selected DB Export button Selected DB Print button Selected DB Delete button...
  • Page 29 3. Setting 3.2. Database result B. DB Search ① Press the [DB Search] button on the top to display the DB Search screen. ② Enter the measurement period or ID to search by using [Button input section] or [Keypad button]. ③...
  • Page 30 3. Setting 3.2. Database result ○ DB Export / Backup ① Insert to the right USB port USB to save database as shown in the [Insert the external storage media] figure. ② If you click , a screen appears to confirm your selection. DB Export DB Back-up ③...
  • Page 31: Measurement

    3. Setting 3.3. Measurement 3.3. Measurement This menu is to set measurement mode of the equipment and the standard value that affects body composition evaluation. Select the sub menu to set at the top. A. Mode Refer to the following description and switch on / off for the test mode (expert / self-test) you want to use. •...
  • Page 32: Standard Setting

    3. Setting 3.3. Measurement B. Information ○ Weight measurement setting Press to set whether to measure or input weight. • Input: When the user steps on the footplate, the user can input weight manually on screen, using [Numeric Key] and [Point Key]. •...
  • Page 33: Print

    Press to set the paper to print the body composition measurement result. • Dedicated paper: select it if you want to use “MEDIANA”-authorized sheet in the pre-set frame. • A4 paper: Select it to use regular A4 paper. C. Auto print and count selection Press to select whether to print the result automatically or not.
  • Page 34: System Setting

    3. Setting 3.5. System setting 3.5. System setting This menu is for managing the equipment system. Select [Advanced Menu] button to set up at the top. A. Date / Time You can set the date and time displayed on the device and result and set the screen saver activation. •...
  • Page 35: Network / System

    3. Setting 3.5. System setting D. Network / System You can set LAN, Wi-Fi communication. ○ LAN Setting ① Press the [LAN] button to display the setting screen about IP, Gateway, Net mask. ② After selecting the box, input value directly. ③...
  • Page 36 E. Home screen type setting Press to the home screen to set up. Changed home screen will be displayed in preview. [Scale] type displays scale indicator and numbers. [I50] type displays body composition analyzer device image and measurement guide message.
  • Page 37: User Setting

    3. Setting 3.5. System setting F. User Setting You can set the user's logo, name, address and contact. The logo is displayed on the top of the result sheet. • Name: You can enter the user's name. If an image is not been set, the name will be displayed on the top of the result sheet.
  • Page 38: Service

    If technical information is needed, contact local dealer or service center and order the service manual. Service manual contains useful information such as how to inspect or repair I50. When contacting service center, let them know the software version of the equipment.
  • Page 39: Firmware Update

    4. Service 4.2. Self-resolution A. Firmware update Firmware update process is as follows. ① Insert the USB memory which the update file is stored to the USB slot(right side) located at the back of the device. Update file must be saved in the Root folder (F:\Update) of USB memory. ②...
  • Page 40: Recycling And Disposal

    4. Service 4.3. Recycling and disposal 4.4. Product return 4.3. Recycling and disposal If the product has reached its life expectancy, it should be disposed of properly according to local disposal policies. • Proper disposal can prevent harmful effects on the environment and health. For more information, contact local authority, waste center, or purchase place.
  • Page 41: Transportation And Storage

    4. Service 4.5. Transportation and Storage 4.5. Transportation and Storage ○ Shipping Precautions For safe transport, at least two people should move the equipment horizontally, parallel to the ground. ○ Repacking instructions When moving the equipment, repack it according to the following sequence. Turn off and separate the adapter and cables from the equipment.
  • Page 42: Transportation And Storage Environment

    4. Service 4.5. Transportation and Storage 4.6. Maintenance ○ Transportation and storage environment The shipping and storage environment of this product is as follows. Proper temperature -10~60°C Relative humidity 10~80% (Noncondensing) Titration pressure 50~101.3kPa 4.6. Maintenance Do not pour any liquid substances on the product. If it occurs, wipe and dry it up completely before use. If safe use of the equipment cannot be ensured, stop using it and contact service center for proper inspection.
  • Page 43: Regular Safety Check

    4. Service 4.7. Regular safety check 4.7. Regular safety check For safe use, please check following list on a daily basis. • Check for physical damage on surface of device, hand/foot electrodes, power cord and adapter. • Check the connection of power cable and the connection of DC jack of adapter. •...
  • Page 44: Specifications

    • Segmental Analysis: Segmental Fat, Muscle, Body Water, Extracellular Water Ratio, and Body Balance Assessment • Weight Control: Obesity Degree, Desirable Weight, Weight/Fat/Muscle/LBM Control • Mediana Score, Extracellular Water Ratio, FMI, FFMI, SMI, Body Cell Mass, Segmental Impedance, Whole Body R / Xc / φ Analysis Items •...
  • Page 45: Manufacturer's Emc Declaration

    6. Manufacturer’s EMC Declaration 6. Manufacturer’s EMC Declaration The I50 is suitable for use in the specified electromagnetic environment. The customer and/or user of the I50 should assure that it is used in an electromagnetic environment as described below. CAUTION •...
  • Page 46 250/300 cycle At 0° At 0° Power 30 A/m 30 A/m It may be necessary to position the I50 further frequency from the sources of power frequency magnetic (50-60 Hz) fields or to install magnetic shielding. The power magnetic field...
  • Page 47 Electromagnetic Environment Guidance Level test level The I50 is intended for use in the electromagnetic environment specified below. The customer or the user of the I50 should assure that it is used in such an environment. Portable and mobile RF communications equipment...
  • Page 48: Recommended Separation Distances

    RF communications equipment and the monitor The I50 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the I50 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the I50 as recommended below, according to the maximum output power of the communications equipment.
  • Page 49 6. Manufacturer’s EMC Declaration ○ Immunity to proximity fields from RF wireless communications equipment (IEC60601-1-2) Immunity Test Maximum Band Distance frequency power Service Modulation test level (MHz) (MHz) (V/m) Pulse 380 – 390 TETRA 400 modulation 18 Hz FM c GMRS 460, ±...

Table of Contents