INSTALLATION INSTRUCTIONS FOR DROPSPOT™
Sloan Valve Company ("Sloan"), warrants its products against defects in materials and workmanship, excluding damage caused by matters beyond Sloan's
reasonable control. Instructions for filing claims can be found in the Limited Warranty which can be obtained at www.sloan.com or by requesting a free copy by
telephone at 888.756.2614. Sloan will repair or replace your defective product, or provide a refund, as your exclusive remedy. This is only a general summary of
Sloan's Limited Warranty so it is important to note that the specific terms, conditions, limitations and exclusions, including the duration of warranty coverage for
your particular Sloan product, are contained in the actual Sloan Limited Warranty. The Limited Warranty is subject to applicable laws in your country, state, province
or other jurisdiction—and disputes arising under the Limited Warranty are to be resolved by binding arbitration unless you provide Sloan with an opt-out notice no
later than 30 days after your purchase date. In case of a conflict with this summary, the terms and conditions set forth in the complete Limited Warranty will prevail.
IMPORTANT INFORMATION
Some options may slightly alter installation. To ensure proper installation, review this document thoroughly and verify rough-ins before beginning any
work. File this document with the owner or maintenance personnel upon completion of installation.
Sloan products are designed in accord with applicable National Codes and Standards, which may include UPC, ANSI, and ASSE. Installers should use industry
standard practice for details not covered within this document. ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the local code
authority and is the responsibility of the installer for verification.
Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. Debris or foreign material in water supply
may damage valve. An appropriate thread sealant is recommended on all MPT threaded waste and supply connections to reduce the possibility of leaks. Thread
sealant NOT recommended for slipjoint or gasketed connections.
Industry standard wall backing substrate, for wall hung fixtures, is required. Installer provided wall anchors and wall anchoring hardware must be appropriate for
wall construction and be able to support three (3) times the weight of the unit.
Electrical receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC (National Electrical Code). This fixture is intended to
dispense water that has been lowered in temperature, but otherwise remains unchanged by the materials in the water cooler. It is common for electrical equipment
to be grounded to water lines either within a structure or away from it. Every attempt should be made to prevent this kind of grounding from generating electrical
feedback into the water cooler creating electrolysis. Electrolysis will cause a metallic taste or cause water metal content to increase.
NOTICE: A dielectric coupling must be used to connect the water cooler to the water supply. A nonmetallic coupler is furnished with this water cooler to meet this
requirement.
ON-WALL BOTTLE FILLERS
DRS-110
Bottle Filler with Single Level Cooler
SLOAN
®
LIMITED WARRANTY SUMMARY
1
Code No. 68160071
Rev. 2 (09/24)