  • Page 1 EBA 6.5 ESCAPE BREATHING APPARATUS Instruction Booklet P/N 300024 Rev. B...
  • Page 2: Donning Procedure

    1. Pull latch release rod. INSTRUCTION BOOKLET P/N 300024, DWG A14861, Rev. B, ECN 4226 The Ocenco EBA 6.5 self-contained, closed circuit, compressed oxygen, breathing 2. Lift and pull each latch ring to release bands. apparatus. The EBA 6.5 instantly provides...
  • Page 3 5. Place neck strap overhead. 3. Remove cover from base by grabbing the handle straps and pulling the case apart. Discard cover. 6. Pull mouthpiece toward face. The mouthpiece plug will automatically be removed from the mouthpiece. Insert mouthpiece in mouth and 4.
  • Page 4: Service Life

    EBA 6.5 inspections are visual. DO NOT open the clear case to inspect the EBA 6.5. If worn or The EBA 6.5 as a whole is designed for a service life of fifteen years if properly inspected and if the...
  • Page 5 HOW TO CARE FOR THE EBA 6.5 Gauge pressure below 2500 psi or above The EBA 6.5 is designed to be carried or stored 3200 psi at 21°C. in a confined space environment. However, like all escape breathing devices it is not No factory installed latch seals attached.
  • Page 6 ADDITIONAL USER INSTRUCTIONS WHEN TO USE THE EBA 6.5 WARNING. The EBA 6.5 should be used immediately at the first indication of fire or explosion, even if smoke 1. Failure to properly use and maintain this is not visible. Carbon monoxide is odorless and product could result in injury or death.