TZ04 In Wall Dual relay(1 way) switch module
Fig 1. Assembling
This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled
device and is fully compatible with any Z-WaveTM enabled network. Mini size design
let the module can easily hide itself into the wall box and that will be good for the
house decoration.
There are many kind of application by using the module to switch AC power On and
Off , one main application is the light control. The new smart relay calibration
technology can reduce the inrush current caused by the load and let the module work
perfectly with many kind of light like incandescent, fluorescent and LED light.
This in-wall switch module is able to detect Instant power wattage (5~1500W) and
overload wattage (1600~1700W) of connected light or appliances. When detecting
overload state, the Module will be disabled and its On/Off button will be lockout of
which LED will flash quickly. However, disconnect and re-connect the Module will
reset its overload condition to normal status.
TM
Adding to Z-Wave
Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carry out inclusion, exclusion, reset or association. When
first power is applied, its LED flashes on and off alternately and repeatedly at
2-second intervals. It implies that it has not been assigned a node ID and cannot
work with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not
have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 4 minute during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike "inclusion" function as
shown in the table below, the execution of auto inclusion is free from pressing the
On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function
Description
No node ID
The Z-Wave Controller does not allocate
a node ID to the Switch.
Inclusion
1.
Have Z-Wave Controller entered
inclusion mode.
2. Pressing
INCLUDE_BUTTON
times within 1.5 seconds will enter
inclusion mode.
Exclusion
1.
Have Z-Wave Controller entered
exclusion mode.
2.
Pressing
INCLUDE_BUTTON
times within 1.5 seconds will enter
exclusion mode.
Node ID has been excluded.
Z-Wave TZ04
User Manual
LED Indication
2-second on, 2-second off
One press one flash
three
One press one flash
three
2-second on, 2-second off
Reset
1.
Pressing
INCLUDE_BUTTON
times within 1.5 seconds will enter
inclusion mode.
2.
Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
3.
IDs are excluded.
Association
1.
Have Z-Wave Controller entered
association mode.
Or Pressing
INCLUDE_BUTTON
times within 1.5 seconds will enter
association mode
2. There are 3 groups for the switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type
LED Indication
Normal
Whatever we switch On and off of the TZ04 by S1 S2 or On/Off
button or RF command , the LED will lights up 1 second and then
off.
No node ID
Under normal operation, when the Switch has not been allocated
a node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Overload
When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the Switch to
the main power
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4.
After putting it into use, the body of Switch will become a little bit hot of which
phenomenon is normal.
Installation
1. put the in wall switch into a wall box and connect the AC power wire L,N to TZ04
connector L, N.
2. Connect the wall switch to the TZ04 as Fig1 .
3. To manually turn ON the Switch, press and release the On/Off button. The LED
will light ON for 1 second, and the load plugged into the Switch will also turn ON.
4. To manually turn OFF the Switch, simply press and release the On/Off button.
The LED will light ON for 1 second and the load plugged into the Switch will turn
OFF.
three
One press one flash
2-second on, 2-second off
One press one flash
three

Advertisement

loading
Need help?

Need help?

Do you have a question about the TZ04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Z-Wave TZ04

  • Page 1 The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the 1. put the in wall switch into a wall box and connect the AC power wire L,N to TZ04 Setup function, and to include/exclude/associate devices connector L, N.
  • Page 2 2-1-3 overload alarm report command 1. Basic Command Class / Binary Switch Command Class When TZ04 detect the overload , it will send Alarm Report to the correspond The Switch will respond to BASIC and BINARY commands that are part of the Group Z-Wave system.
  • Page 3 ON(0xFF) either Relay 1 or Relay2 is ON, report OFF (0x00) when both Relay 1 and Relay2 OFF . If endpoint set to 2 , TZ04 will reply state of Relay1 . If endpoint set to 3 and TZ04 will reply state of Relay2...
  • Page 4 (Meter report = Endpoint3) 2-3-5 METER_GET (Bit Address+Destination End Point = 0x05) (Bit Address =0 Destination End Point Using meter get command to get the KWH,W,V,I,PF from endpoint of TZ04 = command owner Endpoint value) 2-3-5-1 Get KWH from endpoint...
  • Page 5 (Bit Address =0 Destination End Point (Bit Address+Destination End Point = Parameter 1 = 0x20 (Scale = V = 0x04) 0x03) range1~3) TZ04 AC load Voltage report example: Command Class = 0x32 ( Command_Class_Meter_V3 = 0x32) COMMAND_CLASS_MULTI_CHANNEL Command =0x01 (Meter_Get = 0x01)
  • Page 6: Troubleshooting

    3-1 Watt Meter Report Period: 4. Command Classes If the setting is configured for 1hour (set value =720), the TZ04 will report its instant The Switch supports Command Classes including power consumption every 1 hour to the node of correspond Group.