Summary of Contents for Alert-it Advanced Pager P137
Page 1
This document applies to; Model: P137 Product Version: Firmware: v8.13+ Alert-iT and the Alert-iT logo are either registered trademarks or trademarks of iTs Designs Ltd. Copyright @ 2023 iTs Designs Ltd. All rights reserved. UH1068B-ENG P137 User Manual. Version: 8.2.0 [24 Oct 2023].
Supervisor/Maintenance Pager......................10 MENU CONTROL...........................11 Example edit............................11 USER MENU STRUCTURE........................12 SUPERVISOR MENU STRUCTURE......................13 MENU FEATURES..........................14 ANSWERING AND ALARM CALL......................15 CHANGING A ROOM ALLOCATION.......................16 MAINTENANCE.............................17 13.1 Charging...............................17 13.2 Battery Status............................17 13.3 Cleaning..............................17 LIABILITY OF THE MANUFACTURER......................17 DISPOSAL OF THE DEVICE AFTER USE....................17 www.alert-it.co.uk...
See page 17 for recycling guidance. If any cracks or structural damage is observed, cease the use and replace the P137 immediately. NOTE: the batteries must be recharged when the P137 does not start or if display indicates “ For service lifetime of the various monitors and sensors please refer to their own individual IFU’s. www.alert-it.co.uk...
Indicates that the product is in compliance with the European directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment (commonly referred to as the Restriction of Hazardous Substances Directive or RoHS). www.alert-it.co.uk...
Safety Precautions This Alert-iT product has been designed with due regard to reliability and integrity. While it offers a highly vigilant alerting method, it is always possible that a distress condition can go undetected for a variety of reasons (including malfunction) and in life threatening situations it is advisable to use the Alert-iT system in conjunction with additional techniques.
● the death of a patient, user or other person ● the temporary or permanent serious deterioration of a patient's, user's or other person's state of health ● a serious public health threat. Manufacturer’s contact information can be found on the back page of this document. www.alert-it.co.uk...
● The indication may be accompanied by audible alert and/or vibration. ● The caregiver can temporarily silence the sound/vibration with one key press. ● The caregiver attends to the patient and reset the alarm in their room. ● The pager automatically resets itself. www.alert-it.co.uk...
“ ” button until “ ” is displayed, then press the “ ” button to turn off. Warning: Do not remove the batteries to turn the device off, as this may damage the battery contacts. www.alert-it.co.uk...
If the carer pagers are restricted to patient alarms only, then at least one pager in the system MUST: ● Indicate faults (such a battery low). ● Indicate NEW monitors in the area (optional). ● Can be set to SILENT provided it is regularly reviewed. www.alert-it.co.uk...
Next step will be to accept the value with left key, repeat entry with the left key or abort the process with the Menu key. Left and right keys change the option. Select key to activate the selected option, menu key to abort leaving function unchanged. www.alert-it.co.uk...
Light Vibrate* RF tune Tunes Silent select Node select Node Beep Rename NodeInfo View Address chan Type etc select/UP All users Available to extended users& supervisor *Tunes automatically on if Vibrate off (unless Silence enabled by Superviusor in FUNCTION www.alert-it.co.uk...
Useful to silence alarm if equipment node off List Scroll left & right through the list List only shows activated nodes of nodes and press up to select one for detailed menu Rename The node name can be changed www.alert-it.co.uk...
Press UP key (SEL) to silence Tune and display list of active Alarms Press RIGHT key to display second alarm Press LEFT key to scroll back (press again for any more alarms) Attend patients & Reset all ALARMs in bedrooms Red Light off Tune Silent www.alert-it.co.uk...
Use up/down key to set first number Press Right to select second number Use up/down key to set second number Press Left key (OK) to end edit Press Left key (YES) to save Press Right key (No) to abort www.alert-it.co.uk...
LIABILITY OF THE MANUFACTURER iTs Designs Ltd. (T/A: Alert-iT Care Alarms) is liable to ensure the safety, reliability and performance of the device, provided that: ● the device is used and cleaned in accordance with the instructions in these instructions for use.
Medical Device Directive 93/42/EEC as an accessory suitable to support a medical device. The manufacturer, iTs Designs Ltd., hereby declares that this product is in compliance with the Radio Equipment Directive (2014/53/EU). The full text of the EU declaration of conformity is available at the following Internet address; www.alert-it.co.uk/support/ www.alert-it.co.uk...
Page 20
ITs Designs Ltd, T/A: Alert-iT Care Alarms Fernie House (Unit 3) Coalville Business Park Jackson Street Leicester, UK LE67 3NR www.alert-it.co.uk Leisner ApS Korsvangcentret DK - 5610 Assens Denmark For support please contact your equipment provider. EU Importer to add details here, where applicable.