SEELEY INTERNATIONAL Braemar SDHS Series Owner's Manual

Three phase ducted inverter

Advertisement

Quick Links

OWNER'S MANUAL
THREE PHASE DUCTED INVERTER
SLEEP
FAN
MODE
ENTER/CANCEL
FUNCTION
TIMER
SWING
ON/OFF
(English) (SDHS SERIES)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Braemar SDHS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SEELEY INTERNATIONAL Braemar SDHS Series

  • Page 1 OWNER’S MANUAL THREE PHASE DUCTED INVERTER SLEEP MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF (English) (SDHS SERIES)
  • Page 2: Main Components

    MAIN COMPONENTS IMPORTANT IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is As with any product that has moving parts or is subject to wear and tear, it is INDOOR UNIT VERY IMPORTANT VERY IMPORTANT that you maintain your air conditioner and have it regularly...
  • Page 3: Table Of Contents

    MAINTENANCE & SERVICE................AMBIENT TEMPERATURE ENQUIRY ............27 MAINTENANCE SCHEDULE ................INDOOR FAN SHUTDOWN MODE ............28 OPERATION TIPS..................... ERROR DISPLAY...................29-31 TROUBLESHOOTING ..................MAINTENANCE & SERVICE................32 MAINTENANCE SCHEDULE ................33 OPERATION TIPS.....................34 TROUBLESHOOTING ..................35 SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 4: Indoor Unit

    MAIN COMPONENTS INDOOR UNIT SLEEP MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF OUTDOOR UNIT Air inlet 1. Power Cord 2. Wired Controller 3. Binding tape 4. Liquid Pipe 5. Gas Pipe 6. Drain Pipe Air outlet SDHS Three Phase Ducted Inverter Unit...
  • Page 5: Introduction And Safety

    A return air filter MUST be installed by persons in order to avoid a hazard. the installer at the return air grille. The air filter should be inspected and cleaned at least every two weeks SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 6 OPERATION OPERATION MAIN COMPONENTS Ducted Inverter Air Ducted Inverter Air CONTROLLER LAYOUT CONTROLLER LAYOUT Your Braemar Your Braemar Conditioning Unit Conditioning Unit has been designed has been designed Appearance and LCD Icons Appearance and LCD Icons INDOOR UNIT and built with reliable, quality and built with reliable, quality components.
  • Page 7 The unit will resume the original setting state after power recovery. Current set fan speed Turbo function Air status, Indoor unit (OPTIONAL FUNCTION) Energy-saving function Reminder to clean the filter Ambient/setting temperature SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 8 OPERATION cont. LCD ICONS cont. Quiet status (including Quiet and Auto Quiet) Allow auxiliary electric heating On icon (NOT APPLICABLE) Light On/Off function wired wall controller X-fan function Health function, Indoor unit optional function Reserved function (NOT APPLICABLE) Absence function Outdoor unit defrosting status Gate-control function (OPTIONAL FUNCTON) Shielding status...
  • Page 9: Button Functions

    SLEEP SLEEP MODE MODE ENTER/CANCEL ENTER/CANCEL • Air function setting • Save setting FUNCTION TIMER SWING ON/OFF FUNCTION TIMER SWING ON/OFF • Filter clean setting OFF State of the Unit ON State of the Unit SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 10: Temperature Setting

    OPERATION cont. MAIN COMPONENTS MODE SETTING TEMPERATURE SETTING cont. Under the ON state of the unit, press INDOOR UNIT the Mode button to switch the operation modes as the sequence shown below. Auto Cooling Heating SLEEP MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF 1.
  • Page 11: Right-Left Swing Function

    Unit On, no right-left swing SLEEP MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF Press “Enter/ Cancel” button to cancel right-left swing function Press “Function” button to set right- left swing function SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 12: Turbo Setting

    OPERATION cont. TURBO SETTING TURBO SETTING cont. Press FUNCTION button to switch When in FAN setting Press to “TURBO” function. The TURBO icon FUNCTION will flash. Press the ENTER/CANCEL button to enter TURBO to start function. When the “TURBO” the TURBO function is activated the “TURBO”...
  • Page 13: Timer Setting

    MODE ENTER/CANCEL FUNCTION TIMER SWING ON/OFF NOTE: For the GENERAL TIMER setting to activate, Parameter setting P33 will need to be set during installation. If the GENERAL TIMER cannot be activated consult the installation manual. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 14 OPERATION cont. MAIN COMPONENTS CLOCK TIMER CLOCK TIMER cont. Setting when the Unit is INDOOR UNIT CLOCK TIMER “On/Off” setting is The CLOCK TIMER allows you to set shown below the time of the day for the air conditioner to switch on or off. Press TIMER button to enter Setting the CLOCK TIMER function...
  • Page 15: Timer Setting

    Press “ ” or “ " button to Press "Mode" button to set activated, press the Function button to activate timer function adjust timer timer on SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 16: Air Exchange Setting

    TIMER SWING ON/OFF the "SLEEP" function option and then press the Enter/Cancel button to activate it. Sleep off: When the Sleep function is activated, press the Function button to SDHS Three Phase Ducted Inverter Unit SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 17: Sleep Setting

    If the setting temperature is 25°C, SLEEP function, only the SLEEP the temperature will rise by 1°C in function will be deactivated. SDHV Series Ducted Inverter Unit SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 18: Save Function Setting

    OPERATION cont. OPERATION cont. MAIN COMPONENTS SAVE FUNCTION SETTING SAVE FUNCTION SETTING cont. HEALTH SETTING cont. I-DEMAND SETTING cont. Press “Function” The SAVE setting will make the air Notes: INDOOR UNIT button to set conditioner operate in a smaller I-DEMAND Press 1.
  • Page 19 Turbo function Press the FUNCTION button to select the Filter Clean Reminder Function, Energy-saving function then press ENTER/CANCEL to dismiss the reminder, this will reset Ambient/setting temperature the filter reminder. SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 20: Quiet Function Setting

    OPERATION cont. QUIET FUNCTION SETTING cont. QUIET FUNCTION SETTING “QUIET” function setting is as shown Press the FUNCTION button to select below. “QUIET ” function. The “QUIET” icon will flash. Press ENTER/CANCEL button to activate. Unit On, no QUIET function When the “QUIET”...
  • Page 21: X-Fan Setting

    When this function is on, press to your unit). FUNCTION button to select Absence. The “ ” icon will blink. Press ENTER/CANCEL button to turn off this function. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 22: Light On/Off Setting

    MAIN COMPONENTS OPERATION cont. OPERATION cont. GATE-CONTROL FUNCTION cont. E-HEATER SETTING cont. ERROR DISPLAY BLOW FUNCTION SETTING cont. Press “Enter/ Unit On, no BLOW When an error occurs to the unit, NOTE: INDOOR UNIT Cancel” button to function the error code will be shown on the The model cannot be connected cancel E-HEATER wired controller.
  • Page 23: Error Codes

    " " and " " to adjust till "00" is Over-Ratio Protection Error inversely Ambient/setting temperature shown on the timer area. Then press "Enter/Cancel" button to cancel the “FILTER” function. SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 24 Temperature drift protection Defrosting Compressor 6 Current Bus low voltage protection Temperature Sensor 2 Sensor Error Error Bus high voltage protection Charge loop error Input voltage abnormality Drive memory chip error SDHS Three Phase Ducted Inverter Unit SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 25 Outlet Pipe Temperature Indoor Air Box Sensor Incompatibility Error Sensor Error Error Inconsistency of Group-controlled Indoor Outdoor Air Box Sensor Humidity Sensor Error Units in Reheat Error Dehumidification System Outdoor-Indoor Water Temperature Incompatibility Error Abnormality SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 26 OPERATION cont. OPERATION cont. MAIN COMPONENTS OPERATION cont. OPERATION cont. DEBUGGING CODES QUIET FUNCTION SETTING cont. QUIET FUNCTION SETTING Press “Enter/ Press "Function" button to select Error Error Error INDOOR UNIT Content Content Content Cancel” button to Code Code Code QUIET function.
  • Page 27: Lock Function

    Note that any residual or spilt refrigerant oil should be mopped up and disposed of as described above. power recovery. 4. After removal from position the Unit parts may be disposed of according to local laws and regulations SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 28: Maintenance And Service

    MAINTENANCE & SERVICE AIR FILTER with other debris that may build up over time, namely, leaves and the like. It is important to check and clean the air filter as per the Maintenance Schedule below. A dirty air filter will not REFRIGERANT allow the correct amount of clean air to pass through your air conditioner,...
  • Page 29: Maintenance Schedule

    Braemar Ducted Inverter Air Conditioning Unit as per the items and frequency set out in the Schedule, and as indicated elsewhere in this Manual. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 30: Operation Tips

    OPERATION TIPS MAIN COMPONENTS OPERATION TIPS The following events may occur during normal operation: The following events may occur during normal operation: 1. Protection of the air conditioner. INDOOR UNIT 1. Protection of the air conditioner. Compressor protection Compressor protection •...
  • Page 31: Troubleshooting

    Probable Cause Remedy Problem Probable Cause Remedy 1. The air conditioner Seeley International strives for continuous product improvements, therefore specifications are subject to change 1.1 Power failure. 1.1 Wait for power to resume. Icons Introduction 1. The air conditioner without notice. Unit colour may vary slightly from that depicted in this booklet.
  • Page 32 Warranty Registration (Australia Only) To register your warranty, go to www.seeleyinternational.com Warranty Service Australia: 1300 650 644 New Zealand: 0800 589 151 seeleyinternational.com It is the policy of Seeley International to introduce continual product improvement. the model selected. SDHS-01-A AU 2405...