PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL
VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER).
DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
Vertical Vent Installation
10'
8"
18"
Shroud
6"
Wood Surround
These examples show two styles of vertical install. These require Spacer Kit # ACI-3VL.
The framed openings for these installations need to be:
Tradition
Height
21"
Width
30"
Depth
17"
If constructing a chase, adequate, insulation, vapor barrier, drywall, and caulking must be used.