HEATING SPECIFICATIONS
Approx. Heating capacity (sq. feet) *
Approx. Fuel burn rate per hour **
Hopper Capacity - Traditional Stove / Insert
Hopper Capacity – Bay View Free Standing
Hopper Capacity – Bay View Insert / Built-In
* Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside
temperature. Fuel size, quality, density and moisture level will also have an effect.
** Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use
PFI listed fuel for best results.
DIMENSIONS
24"
Traditional Freestanding
24"
Bay View Freestanding
ELECTRICAL SPECIFICATIONS
Electrical Rating
Watts (operational)
Watts (optional igniter)
A voltage surge protector or ground fault outlet is required for this unit.
EPA COMPLIANCE
This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test methods
by Warnock Hersey , US.
FUEL CONSIDERATIONS
Your Pelpro pellet appliance, is designed to burn pellets that comply with Association of Pellet Fuel Industries
standards. (Minimum of 40lbs density per cubic ft, ¼ to 5/16' diameter length no greater than 1.5", not less than
8,200 BTU's/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million)
Pellets that are soft, contain excessive amounts of loose sawdust, have been or are wet, produce clinkers and/or
heavy ash will result in reduced performance and may actually cause the fire to go out.
Can
adian Comfort Industries
Copyright 2004
S
PECIFICATIONS
24 3/4"
24 3/4"
24"
24"
6 1/2"
6 1/2"
28 3/4"
Exhaust
Exhaust
+
+
+
+
8 1/4"
8 1/4"
Air Inlet
Air Inlet
26"
25"
7"
30"
Exhaust
Exhaust
+
+
+
8 1/4"
Air Inlet
Air Inlet
V04
www.pelprostoves.com
800 – 2,000
1.5 – 5 lbs
40 lbs
Approx. Burn time at lowest setting
60 lbs
Approx. Burn time at lowest setting
40-60 lbs
Approx. Burn time at lowest setting
Shroud 1"
12 1/4"
10 3/4"
17 1/4"
17 1/4"
12 3/4"
12 3/4"
24"
Traditional Insert / Built-In
Shroud 1"
12 1/4"
10 3/4"
Ad justab le
Hopp er
17"
12 3/4"
24"
Bay View Insert / Built-In
= 110-120 Volts 60 HZ 2.0 Amps
= 175 (approximately)
= 475 (approximately)
6
24 3/4"
24"
6 1/2"
Exhaust
18 3/4"
+
3 ½"
+
8 1/4"
Air Inlet
26"
24"
19"
6 ½"
-
Exhaust
Exhaust
23"
+
+
3 ½"
+
8 1/4"
Air Inlet
PELPRO OWNERS MANUAL
Dansons Group Inc.
27 hrs
48 hrs
27-48
7 3/4"
7 3/4"

Hide quick links:

Advertisement