Autopilot ChlorSync Gen II Troubleshooting Manual page 2

Advertisement

Message 
No Display / Blank Display 
Lost communication to the display 
‐  ‐  ‐  ‐ 
Alternating: 
Output/24 hr. countdown 
Lo SALt 
Salt level is 2,300 ‐ 2,700 ppm (mg/L) 
Add SALt 
Salt level is below 2,300 ppm (mg/L) 
CLn CELL 
CLn CELL SOOn 
The voltage at the cell is 28 to 30 VDC. 
HIgH Curr Err 
High Voltage or Over Current has been 
detected and the system is locked. 
NO FLO 
OPEn CELL Err 
Cell blades are receiving no current 
SEnS Err 
Connect only one 
red wire for 
PoolSync. If using 
PoolSync on 
additional devices, 
leave red wire off 
on those additional 
devices. 
ChlorSync
Gen II
® 
DISPLAY MESSAGES & TROUBLESHOOTING 
Problem 
No Display 
Alternating Display 
Cell may be scaled 
Insufficient water flow 
A temperature sensor error 
has been detected. 
Black wire from PoolSync to GND 
Yellow wire from PoolSync to A 
Green wire from PoolSync to B 
Red wire from PoolSync to VDC 
RS‐485 Data (+) – Terminal A 
RS‐485 Data (‐) – Terminal B 
RS‐485 Data (+) – Terminal A 
RS‐485 Data (‐) – Terminal B 
Pool cover Switch  
(dry contacts) 
‐ Troubleshooting Guide 
 
1. No power to the Power Center, check breaker. If unit is wired to a time clock,
make sure it is turned on.
2. Transformer wiring is incorrect, check it is wired properly for incoming voltage.
3. Fuse (10A) may have failed, test and replace if necessary. 
4. Transformer or Power Center circuit board has failed, replace the Power Center.
(p/n: PCR0002A or PCR0002J) 
Check 4‐wire cable connecting the display to the power center. 
Normal operation, unit is in BOOST mode. Press and hold both the Up Arrow and
Down Arrow simultaneously to activate/deactivate BOOST  MODE. 
Add Salt to achieve 4,000 ppm (mg/L). 
Add Salt to achieve 4,000 ppm (mg/L). 
Cell voltage is above 30. Check cell for scale, clean as necessary and balance water. 
Chlorine is still being generated.  The cell may be dirty or have calcium build up. 
Inspect and clean the cell as needed. 
Fresh salt may have not fully dissolved, or the salt level may be above 5000ppm. 
The system will retest every hour. If the condition persists the system will lock out 
and display a high current fault. A power reset will clear the fault. 
1. Check / clean AutoPilot manifold union screen.
2. Increase variable pump speed if necessary.
3. Check pump for proper operation and service, as necessary.
4. Clean / service filter, as necessary.
5. Check system valve settings for proper flow to the unit.
6. Check for heavy scale accumulation on the cell.
7. Check for debris in manifold bypass check valve. Ensure valve is properly seated
when pump is off.
8. Check Tri‐sensor connection at power center.
9. Tri‐sensor may need to be serviced or replaced.
Confirm banana plugs are plugged in. Check for loose or damaged wiring inside 
the power center. After correcting, power cycle the power center to clear error. 
Use 986ST simulator to diagnose error 
10-amp, automotive type, mini blade fuse
ORP input (dry contact)  
Solution 
LTM1034 rev C (2 of 2) 