Date: 6/26/2023
Return Request: 6/30/2023
Project: Little Rock Convention Center – Atrium
Supplier: Falk
Submittal: Plumbing Fixtures Re-Submittal #1
Submittal Number: 22 40 00-01
Drawing # and Installation: Plumbing Drawings
ARCHITECT
Witsell Evans Rasco
901 West Third Street
Little Rock, AR 72201
501-374-5300
GENERAL CONTRACTOR
Wagner General Contractor
600 W. Race Ave.
Searcy, AR 72143
501-203-0704
Notes:
*Model number for L-1 is #676 which is a discontinued model; #768 is the model that is replacing it.
ENGINEER
Pettit & Pettit
201 E. Markham, Suite 400
Little Rock, AR 72201
501-374-3731
MECHANICAL SUBCONTRACTOR
Comfort Systems USA (Arkansas), Inc.
9924 Landers Rd.
N. Little Rock, AR 72117
501-834-3320
CSUSA PROJECT NO.
23-1015
jon@comfortar.com
Comfort Systems USA (Arkansas), Inc.
P.O. Box 16620
Little Rock, AR 72231
Phone 501-834-3320
Fax 501-834-5416

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EcoPower and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Toro EcoPower

  • Page 1 Comfort Systems USA (Arkansas), Inc. P.O. Box 16620 Little Rock, AR 72231 Phone 501-834-3320 Fax 501-834-5416 Date: 6/26/2023 Return Request: 6/30/2023 Project: Little Rock Convention Center – Atrium Supplier: Falk Submittal: Plumbing Fixtures Re-Submittal #1 Submittal Number: 22 40 00-01 Drawing # and Installation: Plumbing Drawings ARCHITECT ENGINEER...
  • Page 2 LR Convention Center East Atrium Renovations Plumbing Operations and Maintenance...
  • Page 3 FLUSH VALVES...
  • Page 4 Manuel d’Installation et d’Utilisation Manual de Instalação e do Proprietário EcoPower Flush Valve Fluxómetro EcoPower Valve de Chasse EcoPower Fluxómetro Self Power Warranty Registration and Inquiry For product warranty registration, TOTO U.S.A. Inc. recommends online warranty registration. Please visit our web site http://www.totousa.com.If you have questions regarding warranty policy or coverage, please contact TOTO U.S.A.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS Thanks for Choosing TOTO!........................2 Included Parts.............................2 Common Tools Needed..........................3 z i l ......
  • Page 6: Common Tools Needed

    Two functions help the EcoPower Flush Valve conserve water: Fuzzy Logic Control The EcoPower Flush Valve can sense how often and how long the fixture has been used to deliver the correct amount of water. (See About Fuzzy Logic Control, page 5) Anti Consecutive Flushing The EcoPower Flush Valve offers water saving consecutive flush prevention.
  • Page 7: Specifications

    SPECIFICATIONS Toilet Urinal Figure TET1LAR TET1UAR TET1GAR TEU1LAR TEU1UAR TET1LAX TET1UAX Model Number TEU1GAR TET6LAR TET6UAR TEU1LAX TEU1UAX TET6GAR TET6LAX TET6UAX fuzzy logic 0.5 G (1.9 L) 0.125 G (0.47 L) adj. flush vol. 1.6 G 1.28 G 0.5 G (1.9L) Rated Flush Volume (6 L) (4.8 L)
  • Page 8: Technical Information

    TECHNICAL INFORMATION About TOTO's Hydropowered Generator The flow of water causes the turbine in the power generator to rotate. This process generates electric power and enables the automatic Flush Valve to operate. See ill. 1 below. TET1GAR Sensor eye TET6GAR c i t TEU1GAR Flush Valve...
  • Page 9: Warnings

    Never splash water on the controller. The EcoPower Flush Valve is an electric appliance. Risk of product malfunction. Do not strike or kick the EcoPower Flush Valve. Risk of product malfunction or water leakage. Do not use the EcoPower Flush Valve at temperatures exceeding what local codes or product specification allow.
  • Page 10: Installation Procedure

    INSTALLATION PROCEDURE NOTE: For retrofit installation, remove the old Flush Valve after shutting off the control stop. NOTE: For reclaimed water, do not use standard vacuum breaker or control stop. NOTE: Do not use petroleum based products or pipe sealants. 1.
  • Page 11 INSTALLATION PROCEDURE 4. Prior to inserting the Flush Valve tailpiece into the control stop, make sure that the o-ring is in the groove at the end of the tailpiece, the locking nut and the snap ring are located as shown. 5.
  • Page 12 INSTALLATION PROCEDURE 9. Fasten the sensor top cover to body assembly with the supplied screws and hex wrench. Protect the wire connections inside the top cover. Hex wrench 10. Before the supply water is turned on, Pipe connection be sure all water leaks are eliminated by tightening all the pipe connections.
  • Page 13: Test Run

    PERIODIC MAINTENANCE Please check your EcoPower Flush Valve at least once a month according to the following instructions to avoid risk of property damage. Check the piping to see whether there is any leakage.
  • Page 14: Using The Flush Valve

    USING THE FLUSH VALVE Using the Toilet Flush Valve Infrared Sensor Flushing Flushing Every 24 hours The infrared sensor detects When the user stays in place If toilet is not used for 24 hrs, a user of the toilet. longer than 6 seconds then the system automatically moves away, the controller flushes as a maintenance...
  • Page 15: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Suggested Action Ref.Page Open the main valve or the The main valve in water supply control stop line or the control stop is shut off One or more cables not Check all cable connections connected The surface of the glass in front Clean the surface of the glass of the infrared sensor is dirty...
  • Page 16 DISASSEMBLY If the whole valve needs to be removed from the water supply for servicing, please be aware of the cautions below: 1. Be careful not to lose or tear the friction washer at the Hex wrench outlet connection to the vacuum breaker tube nut. To maintain a proper seal, replace the washer if necessary.
  • Page 17: Battery Replacement

    CLEANING DIAPHRAGM AND FILTER 1. Turn the screw on the control stop Sensor unit clockwise to turn off the water. Solenoid 2. Disconnect the solenoid. Spring Sealing area Plunger 3. Remove the solenoid and take out the O-ring diaphragm. Then check the small holes Diaphragm and sealing area.
  • Page 18: Detection Range

    Use chrome plated detect a user if the toilet seat is left elbow to adjust the height of TOTO in an upright position. This can be EcoPower Flush due to the rough-in dimension or Valve from the fixture. Elbow gap of the open front commercial Wall flange...
  • Page 19: Warranty

    WARRANTY 1. TOTO warrants its electronic flush valves, faucets and soap dispensers (“Product”) to be free from defects in materials and workmanship during normal use when properly installed and serviced, for a period of three (3) years from date of purchase. This limited warranty is extended only to the ORIGINAL PURCHASER of the Product and is not transferable to any third party, including but not limited to any subsequent purchaser or owner of the Product.
  • Page 20 FAUCETS...
  • Page 21 Installation and Owner’s Manual Manual de Instrucciones y del Propietario Manuel d’Installation et d’Utilisation Manual de Instalação e do Proprietário T20S* T21S* T22S* T23S* TOTO U.S.A., Inc. 1155 Southern Road, T24S* T25S* Morrow, Georgia 30260 T26S* T27S* Tel: 888-295-8134 Fax: 800-699-4889 T28S* T31S* www.totousa.com...
  • Page 22 TABLE OF CONTENTS / ÍNDICE COMPONENT BREAKDOWN / DESGLOSE DE LOS COMPONENTES TABLE DES MATIÈRES / ÍNDICE VENTILATION DES COMPOSANTS / DESCRIÇÃO DOS COMPONENTES ENGLISH Kit model# ECOPOWER COMPONENT BREAKDOWN....3 INSTALLATION PROCEDURE ....9 x refers to Controller# Controller#...
  • Page 23: Thanks For Choosing Toto

    Gooseneck Axiom Axiom Helix Helix Vessel Vessel Vessel ECOPOWER Touchless Faucet are designed to work for 10 years, under normal conditions, with no minimum usage required. Mechanism for EWATER+ after approx. 3 seconds TLE240* TLE250* TLE260* SPOUT (Wall-Mounted models) Libella...
  • Page 24: Tools You Will Need

    WARNINGS WARNINGS Please read and adhere to the following notes. Failure to do so could result in personal Do not leave abnormalities, such as rattling parts, unaddressed. injury and/or property damage. At least annually, check around pipes for water leakage, replace worn check valves, and turn No person other than a service engineer should disassemble, repair or modify this the temperature control handle of the thermal mixing valve to prevent buildup or sticking.
  • Page 25: Installation Procedure

    TOTO uses water consumption because it is the most accurate method of measuring water cover. use. This method of measurement can be incorporated into water usage calculations for 2. Only ECOPOWER models. (TLE0350*) various efficiency programs. Connect backup battery to controller.
  • Page 26 TLE0150* & TLE0350* TLE0250* To Install Helix Wall-Mounted models Only ECOPOWER models (TLE0350*) If you haven't connected the backup battery, connect the backup battery connector to the controller. Product will require 5 min. to initialize. See "Install the controller" section.
  • Page 27 INSTALLATION PROCEDURE INSTALLATION PROCEDURE Trial Run and Calibration Reinstall the controller cover 1. Place the key into its slot in the controller. Spout 2. Double-check all connections. Reinstall the controller cover, and secure it with the screw. Sensor Sensor cable hose Check for Leaks TLE0150* &...
  • Page 28: Periodic Maintenance

    CARE & CLEANING PERIODIC MAINTENANCE Check your faucet at least once a month for the following potential problems and to do the following maintenance procedures: Inspect for Leakage Check all water connections for signs of leakage. Address any problem. Contact a qualified professional if necessary.
  • Page 29 PERIODIC MAINTENANCE TROUBLESHOOTING Problem Cause Solution Cleaning the filter and the flow regulator The surface of the sensor is dirty. Clean the surface of the sensor. 1. Shut off the water supply at the stop There is an obstruction in front of the Remove the obstruction.
  • Page 30 CONTROLADOR RESPONSIBLE FOR LOSS OF THE PRODUCT OR FOR OTHER INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OR EXPENSES INCURRED BY THE ORIGINAL PURCHASER, OR FOR ECOPOWER EWATER+ LABOR OR OTHER COSTS DUE TO INSTALLATION OR REMOVAL, OR COSTS OF REPAIRS BY OTHERS, OR FOR ANY OTHER EXPENSE NOT SPECIFICALLY STATED ABOVE.
  • Page 31 REVIEW PLUMBING SUBMITTALS Project: LR Statehouse Conv. Center - Atrium Location: Little Rock, AR P&P Job No. 23-023 Date of Receipt: Tuesday, June 27, 2023 Date of Review: Wednesday, July 12, 2023 Reviewed by: Terry Jacks Email: tjacks@pettitinc.com Signed: Checking is for conformance with the design concept of the Project and compliance with the information given in the Contract Documents.
  • Page 32 Josh Brandon Wagner General REMARKS: REVISE AND RESUBMIT o L-1 to be: American Standard Studio Undercounter Sink, 0614.30 o Faucet to be: Toto Helix Ecopower Facuet, TEL115 S Kupers | WER 07.13.2023 CONTENTS QUANTITY: DATED: 6/27/2023 NUMBER: DESCRIPTION: Submitted by Wagner - 22 40 00-01 Plumbing Fixtures Re-Submittal #1.pdf.pdf...
  • Page 33 MATERIAL FURNISHED BY Your Supply House By Choice 223 THIRD STREET, HOT SPRINGS, AR (501) 321-1231 FAX (501) 321-4015 JOB NAME LITTLE ROCK CONVENTION CENTER EAST ATRIUM LITTLE ROCK, AR PLUMBING CONTRACTOR COMFORT SYSTEMS USA NORTH LITTLE ROCK, AR APPROVAL DATE: _______________________________________________ ARCHITECT: _______________________________________________ MECH.
  • Page 34 WC-1,2...
  • Page 35 AFWALL FloWise ADA Retrofit ® ® Elongated Flushometer Toilet VITREOUS CHINA WITH EVERCLEAN ® BARRIER FREE Afwall FloWise ADA retrofit Elongated ® ® Flushometer Toiet with EVERCLEAN ® • Afwall FloWise ADA bowl replaces standard wall-hung 3.5 GPF or 1.6 GPF models and roughs-in at 410mm (16-1/8") rim height to meet ADA with no need to modify the existing carrier or through wall supply (providing...
  • Page 36 AFWALL FloWise ADA Retrofit ® ® Elongated Flushometer Toilet VITREOUS CHINA WITH EVERCLEAN ® BARRIER FREE 2294.011EC / 2296.019EC FINISHED WALL 1" N.P.T. OR C.W.T. SUPPLY AS REQUIRED TO FLUSH VALVE 635mm (25) 121mm (4-3/4) 73mm (2-7/8) 375mm 470mm (14-3/4) (18-1/2) 1-1/2 SPUD C/L OF SEAT POST HOLES...

Table of Contents