Product quick start guide Pin Assignment of Connectors ⚫ CN1 & CN2 : I/O terminal RUN ERR PWR SW301 33 34 IDC Female 2.54mm 34P Connector Function Function Function Function Port#0 bit0 output +24V Port#2 bit0 output +24V Port#0 bit1 output Ground Port#2 bit1 output Ground...
Page 3
Product quick start guide ⚫ CN3 & CN4 : Motionnet communication control connectors RUN ERR PWR RJ45 Connector SW301 To eliminate noise, twisted pair cabling is necessary. Label Function 1,2,4,5,7,8 Reserved Differential D+ signal Differential D- signal ⚫ CN5 : Power input RUN ERR PWR SW301...
Page 4
Product quick start guide ⚫ SW301: Device configuration switch RUN ERR PWR SW301 A5 A4 A3 A2 A1 A0 B1 B0 TD TR 1 2 3 4 5 6 7 8 9 10 Label Description Node IP settings The node number = 32 * A5+16 * A4+8 * A3+4 * A2+2 * A1+A0. Default values are all off.
Product quick start guide LED Indicator RUN ERR PWR LED indicator Digital Output Port 0 Digital Output Port 1 SW301 LED indicator Digital Output Port 2 Digital Output Port 3 Color Description Green Lights on when Motionnet runs. Lights on when Motionnet error occurs. Yellow Lights on when power is on.