Summary of Contents for Esteam Cleaning Systems Defender 500
Page 1
OWNER’S MANUAL Congratulations on your selection of a new Defender portable carpet cleaner built in Canada by Esteam Cleaning Systems. Our goal is to produce the best, high performance line of carpet cleaning equipment on the market today. Reading your...
Years of experience, engineering, and planning have gone into the design and manufacturing of the Defender 500. We take great pride in our equipment; our goal is no less than your complete satisfaction.
• The two power cords must be plugged into separate circuits during operation. • Do not use the DEFENDER 500 outdoors, in standing water or on wet surfaces. Do not store the DEFENDER 500 in wet conditions. If extractor is leaking, unplug machine power cords from outlets before approaching or touching machine.
Page 6
Store, transport, and use this equipment only in temperatures well above freezing. (32ºF or 0ºC). If you suspect the Defender 500 has been frozen, do not plug in or turn on machine until you are sure it has thawed completely.
Operation Procedures Knowledge of the proper operation of the Defender 500 is required to ensure user safety and efficient performance of the extractor. SET UP AND OPERATION 1. Insert electrical cords into 3 pin grounded outlets. Two cord machines maybe equipped with the Optional Circuit Indicator located above the Switch Plate.
Page 8
TO USE YOUR DEFENDER HEATER: A. Hook the wand solution hose to the quick connect of your machine. B. Plug the heater power cord into a wall that is on a separate circuit form the other cord. C. Turn the heater switch on. D.
WARNING: When using electrical equipment around water it is important to wear rubber soled shoes and keep machine properly grounded at all times. Failure to do so could result in electric shock. MAINTENANCE DAILY: - Clean high water level float screen inside the recovery tank. - Ensure high level float ball is working properly.
Bucket & Sprayer Storage The top of the Defender 500 is sized and recessed to hold a five-gallon bucket or two one-gallon chemical bottles as well as two 2QT sprayers.
TROUBLE SHOOTING WARNING: Prior to inspection or repair of this machine, disconnect all electrical cords rendering the machine powerless. Failure to do so could result in serious or fatal injury. PROBLEM CAUSE SOLUTION 1. Entire unit will not 1. Unit not plugged in 1.
Page 12
TROUBLE SHOOTING (CONTINUED) PROBLEM CAUSE SOLUTION 5.Pump runs but 1. Partial kink in solution hose 1. Remove kink has loss pressure 2. Partial blockage in solution 2. Remove blockage hose 3. Jet orifice opening on clean- 3. Total jet opening for 500 ing wand is too large PSI pump should be .06 or 08.
Page 13
TROUBLE SHOOTING (CONTINUED) PROBLEM CAUSE SOLUTION 8. Machine spits water 1. High level float not working 1. Check auto shut off float out of exhaust port properly cage and ball for proper operation 9. Machine blowing 1. Damaged (leaking) 1. Immediately shut unit excessive amounts of recovery tank fittings down.
ESTEAM® CLEANING SYSTEMS DEFENDER EXTRACTOR WARRANTY NOTICE: REVIEW THIS WARRANTY CAREFULLY AS THIS DOCUMENT CONTAINS LIMITATIONS AND EXCLUSIONS. PART I: Esteam Manufacturing. (hereinafter referred to as "Esteam") warrants each new Defender Extractor, subject to the limitations as defined in the specific details of its warranty coverage defined below. LIMITED HOUSING WARRANTY COVERAGE: Esteam warrants the Defender Polyethylene Machine Housing Unit to be free from defects in material and workmanship (including cracking, leaking or deterioration) for three years, expressly subject to the limitations stated herein.
PART II - REPLACEMENT PARTS (UNDER WARRANTY) Replacement warranty parts will be genuine Esteam parts, or parts of similar kind and quality. All replacement warranty parts are warranted to be free from defects in materials or workmanship from the date of the original unit purchase for the balance of the original warranty period namely: 90 days, 12 months, or the Limited Warranty, whichever is applicable;...
Page 16
warranties. Esteam, its officers, directors, agents, dealers and its affiliates (and their respective officers, directors, agents and dealers) shall not be liable to the customer nor to any party for any liability, including without limitation, strict liability, liability for loss, injury or damage due directly or indirectly to the use or operation of the Esteam product;...
Page 17
Require use of a defoamer. A vacuum motor showing moisture contamination on interior components shall void any warranty by Esteam. Pumps: All pumps require daily flushing with clean water after use. Internal Heatermate: The internal heater must be flushed with clean water after every use. Any buildup of hard water deposits or chemical buildup within the internal heater will void any Esteam warranty thusly exclude any liability of Esteam.