Page 2
Version modification Record: Version No. Date Modification Description Initial Release V1.0 2022.11.30...
Page 3
If anything wrong or missing, please contact the distributor or the manufacturer. HANGZHOU ALLSHENG INSTRUMENTS CO., LTD. Add: Building 9 No.7 of Zhuantang Science and Technology Economic Zone, Xihu District, Hangzhou City, 310024 Zhejiang P.R. China Tel.: 0086‐0571‐88859758...
Safety and Operating Precautions 1. Safety Information Users should have a clear understanding of how to use this instrument before operation, please read this manual carefully prior to operation. NOTICE: Operation before reading Manual forbidden,otherwise instrument in operating may cause injury or electric shock.
Page 5
The Instrument should be put in dry place, less dust, far away from water and high‐intensity light. What’s more, the place should be well ventilated, no corrosive gas or strong magnetic interference, far away from heater, stove or any other heat. Power off when you finish your work.
Warranty Warranty content One month from the date of delivery, in case of faults due to material and manufacturing defects, our company will be responsible for replacement. Twelve months from the date of delivery, provide warranty for faults due to material and manufacturing defects.
Fluo‐800 Portable Fluorometer Operation Manual Chapter 1 Introduction Chapter 1 Introduction Fluoroimmunoassay (FIA) technology has advantages of high specificity, sensitivity and utility. Therefore, it is used for detecting biological active compounds of low concentration, such as protein (enzyme, receptosome, antibody), nucleic acid, hormone (steroid, thyroid hormones), medicine and microorganism.
Fluo‐800 Portable Fluorometer Operation Manual Chapter 3 Instrument Structure Chapter 3 Instrument Structure This chapter introduces the structure of instrument. If it is used for the first time, please read this chapter carefully to make a better preparation. Structure 1: Sample holder Display Screen PC port...
Fluo‐800 Portable Fluorometer Operation Manual Chapter 4 Installation Chapter 4 Installation 4.1 Opening Check Each Fluo‐800 has been inspected strictly before packing and transportation. Please check again when you receive it. Contact with your local distributor or manufacturer in case of: ...
Page 12
Fluo‐800 Portable Fluorometer Operation Manual Chapter 4 Installation Sample test steps: ①Insert 8 strip PCR tube into sample hole; ②Close lid; ③Click detecting button on the interface for testing. Pay attention! The test tube should be placed in the same direction each time, and there should be no stains and scratches on the surface, otherwise it will affect the test accuracy! 8 strip PCR tube...
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Chapter 5 Software Introduction 5.1 Self checking This chapter mainly introduces Fluo‐800 program operation. After connect power supply, turn on the switch on the back of instrument. The instrument power on and enter into self checking interface, then into Login interface. Fig 5.
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Button function in main interface: : User choice : Reagent calculation : dsDNA test : RNA test : Oligo test : Protein test : Fluorescence test : Standard curve : Report manage : Settings 5.3 dsDNA test In main interface, click...
Page 15
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction : It can select the wells to be tested. By default, all are selected. : Click to check calibration parameters; : Click to print all current protocol test data; : Click to test current protocol; : Click to modify the protocol name;...
Page 16
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Enter into calibration interface, insert information of standard sample 1 and then sample 2, click read to calibrate, then finish calibration. : It can select the wells need to be calibrated. By default, all are selected.
Page 17
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction : Click to enter the application interface of kit number and sample ID of the sample. : Click to test. 5.3.4 Molarity calculator Click , select Molarity calculator, enter Molarity calculator interface.
Page 18
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction 5.3.5 Normalization calculator Click Normalization button, enter Normalization calculator interface: In the interface, it can choose the type of Normalization, For example Molar concentration, Mass concentration, Mass; And set final sample concentration or mass, and final sample volume.
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Note: As the software function of dsDNA, RNA, Protein, Oligo are same, Only the dsDNA testing are described in detail in the operation manual. 5.4 Fluorescence In main interface, click , the options box is displayed, showing three test types: Blue 470nm, Red 635nm, Blue&Red.
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction 5.5 Calculator Pull the upper button , enter calculator interface: Buffer configuration calculator: Input the number of samples, standard samples, choose whether to include overage samples; After input the corresponding parameters, it will automatically calculate the required volume of dye and buffer liquid .
Page 21
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Fig 5. 22 Standard curve interface Function of buttons in current interface: : Filtered against item, such as dsDNA, RNA, Oligo, Protein; : New standard curve; : Manage standard curve; : Filtered against name; : Filtered against type;...
Page 22
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Fig 5. 23 New curve category selection box Fig 5. 24 New curve interface Function of buttons: : Click to check point data before; : Click to view data of next point. If this is the last one, it can add sample point;...
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Fig 5. 25 Curve manage interface Fig 5. 26 Import curve Function of buttons: : Delete selected curve; : Insert U disk, and import curve from U disk to instrument; : Insert U disk, and export curve from instrument to U disk. 5.7 Report In the main interface, click to enter report interface, input keywords in...
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Click report to check tested data, click the sample again to view the detailed test data. Fig 5. 29 Tested data Fig 5. 30Detailed test data 5.8 User manage Click in the main interface, display : User settings, Administrators can manage common users, add, delete, modify the number and password of common users;...
Page 25
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction Fig 5. 32 Settings interface Function of buttons: System settings Upgrade Maintenance 5.9.1 System settings Fig 5. 32 System settings Click to enter system settings: Language: Select Chinese or English; Date and time: Set system date and time; Screen brightness: Adjust screen brightness;...
Fluo‐800 Portable Fluorometer Operation Manual Chapter 5 Software Introduction 5.9.2 Upgrade Click , enter upgrade interface, display version of software and firmware. Insert U disk with new one, click the software or firmware to upgrade. Fig 5. 33 Upgrade interface 5.9.3 Maintenance Click , input password, enter maintenance interface(Manufacturer user...
Fluo‐800 Portable Fluorometer Operation Manual Chapter 6 Maintenance, Storage and Transportation Chapter 6 Maintenance, Storage &Transportation 6.1 Maintenance Keep storage environment dry and clean to prevent from moisture, corrosion, strong electromagnetic interference sources. Instrument already calibrated before delivery. User is not allowed to disassemble the instrument.
Fluo‐800 Portable Fluorometer Operation Manual Chapter 7 Fault Analysis and Treatment Chapter 7 Fault Analysis and Treatment Fault Analysis and Solutions: Fault Possible Causes Solutions phenomenon Instrument can Check the power supply; Power defective not start Check whether the plug is loose Check the power;...
Need help?
Do you have a question about the Fluo-800 and is the answer not in the manual?
Questions and answers