Summary of Contents for Malema DuraMassFlow CIFM-88 Series
Page 1
DuraMassFlow CIFM-88 Series PFA Coriolis Industrial Flow Meter User Manual...
Page 3
2. EN61000-4-3: Radiated Immunity (and Radiated Emissions) 3. EN61000-4-4: Electrical Fast Transients 4. EN61000-4-5: Surge - Power Line 5. EN61000-4-6: Conducted Immunity Support Email Address Please contact the Malema Customer Support Team at the email addresses below, General Support: Malema.GeneralSupport@psgdover.com Customer Support: Malema.CustomerSupport@psgdover.com Order Support: Malema.OrderSupport@psgdover.com...
Flush the flow path (pumps, piping, tubing) with water prior to disconnecting any plumbing. 1.02 Overview The Malema DuraMassFlow PFA Coriolis Industrial Flow Meter (CIFM) 88 Series leverages the Coriolis principle to simultaneously measure mass flow, density, and temperature with exceptional precision. The CIFM-88 Series Flow Meters are designed for use in harsh industrial environments.
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 1.00 Introduction 1.03 Transport and Storage Guidelines for Flow Meters Storage Recommendations Warning: Risk of Damage from Humidity • Shield from Moisture: Protect the flow meter from rain and humidity. • Humidity Control: Ensure that relative humidity does not exceed 95%. Warning: Risk of Mechanical Wear •...
3.01 Plumbing Connection The DuraMassFlow CIFM-88 Series is available with two process connection types for the Inlet and Outlet ports. The process connection types are orderable in pillar or flare connectors. Figure 3-1: Outlet connector for the DuraMassFlow CIFM-88...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 3.00 Installation 3.02 Electrical Connections 1. Communication and power/signal connectors are located at the bottom. 2. Connect the Power/signal cable, twist the connector clockwise to lock connector, turn counterclockwise to the release. Figure 3-2: The Communication and Power/signal connection ports for the DuraMass 3.
Device Manager. If there is a yellow exclamation mark on the device in Device Manager, install the proper driver from the device manufacturer. 2. Copy the PSG Dover Malema software GUI (an .exe executable file) to a folder on the local drive. The software GUI is available for download.
Page 10
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 3.00 Installation 3.03 PC Software/GUI Communication 5. Main GUI window. Figure 3-11: Main GUI Window 6. Click the “Data” button to start monitoring the flow rate. Figure 3-12: Main GUI with Graph of Flow 7.
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 3.00 Installation 3.04 Zero Calibration To prevent systematic deviations in flow rate measurements, it is recommended to perform a zero-point adjustment prior to initiating measuring operations. 1. Warm-Up Period: Allow the flow meter to warm up for 30 minutes powered on with fluid present in the flow tube. Fluid during warm up can be static during warm up.
Severe error has occurred with an error code indicating the type of failure that has been detected. 2. Flow Zero LED shall go off, Reset Total LED shall stay on while in this error mode. 3. If an Error Code occurs contact Malema.TechnicalSupport@psgdover.com. Figure 3-17: Error Message on the Main Display...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 3.00 Installation 3.06 Transmitter Connector Pin-Out Transmitter Connector Pin-Out Table 3-1: Signal Configurations Modbus 2 Analog Outputs Pin # Color Signal name Signal name +24 V DC +24 V DC Black +24 V DC GND +24 V DC GND Pink DIO IN2+...
Page 14
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 3.00 Installation 3.06 Transmitter Connector Pin-Out Setup Digital Inputs/Outputs Digital outputs 1 and 2 can be set individually as open collector as shown below. Click “Set params.” to activate any changes then click “Store it” to save to non-volatile memory”. Figure 3-18: Selecting Digital Outputs 1 and 2 for Frequency and Alarm Settings Figure 3-19: Selecting Digital inputs 1 and 2 or Input Mode and Force Auto Zero Product Specification and part numbers...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 4.00 Dimensional Drawing For Reference Only Model CIFM-88 with 1/4” fluid connection 3.44 R3.50 12.17 87.30 USE M5 SCREW 309.00 FOR MOUNTING 1.49 37.89 1/4" S300 PILLAR FITTING BOTH SIDES INLET OUTLET 10.07 8.70 255.90 6.46...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 5.00 Ordering Information Model Ordering Code Description 8803-* -*** CIFM- 8803-1 PFA Sensor; 15-1,500 g/min Range Code 8803-2 PFA Sensor; 40-4,000 g/min Display With Local LCD Display 1/4” Process Connection 3/8” Pillar (S 300)- Male Process Connection Type Flare - Male 1x 4-20mA for mass or volume flow (4mA =0 g/min,...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.01 Technical data Interface Bit rate RS485 [kbps] Index 19.2, 4.8, 9.6, 38.4, 57.6, 115.2 8 databits, 1 stopbit, even parity Bit rate RS232 over USB [kbps] 115.2, 8 databits, 1 stopbit, no parity Protocol MODBUS RTU or ASCII...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.04 Getting started with the MODBUS communication • Connect the RS485 interface in half duplex mode. • Connect a RS485 to USB converter between the meter and a PC. •...
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.05 MODBUS protocol Note: The Coriolis mass flow meter/ flow controller uses protocol addresses. This means the register address listed is the actual number required in the MODBUS command. Addressing The used MODBUS protocol registers are addressed and divided into functional equivalent groups: Coil registers:...
Page 20
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.05 MODBUS protocol Coil registers PDU Register Description Settings address (dec) 1001/11001 Reset totals Resets: Write Reset all totals - mass and volume totals Write OFF No effect - flow time...
Page 21
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.05 MODBUS protocol Coil registers PDU Register Description Settings address (dec) 1008/11008 Select flow controller set Write Analog input is selected point source Write OFF Digital set point is selected.
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.05 MODBUS protocol Input registers PDU Register Description and setting Type # of registers address (dec) Mass Flow rate [selected units] 3000/43000 Float Mass Flow total [selected unit] 3002/43002 Float Vol.
CIFM-88 SERIES PFA CORIOLIS INDUSTRIAL FLOW METER 6.00 Appendix Coriolis Meter - Serial MODBUS Version 1.0G 6.05 MODBUS protocol Holding registers Read / Write. Function codes 0x03 or 0x04 for read, 0x10 for write. One register set at a time. PDU Register Description and setting Type...
Malema Sensors shall be relieved of any further obligation to Buyer under this section with respect to such equipment. No equipment furnished by Malema Sensors shall be deemed to be defective by reason of normal wear and tear, failure to resist erosive or corrosive action of any fluid or gas (unless otherwise specified in Quotations), Buyer’s failure to properly store, install, operate, or maintain the equipment in accordance with good industry practices or specific recommendations of Malema Sensors or in accordance with operating manuals and/or product data sheets limits, or Buyer’s failure to...